Trainer: Dr. Saeed Roostaee (Profile)
SIPROTEC 5 Hardware and Online Configurator
- SIPROTEC5 Hardware
- DIGSI 5 installation and DDD
- General Settings
- DIGSI 5 User interface
- New project
- Add device
- SIPROTEC5 Online Configurator
- Function Point
- SIPROTEC5 Configuration Procedure
SIPROTEC5 Online Mode
- Connect to SIPROTEC 5
- Working with SIPROTEC 5 in online mode
- Indications
- Fault Recording
- Log
- Reading Indications on the On-Site Operation Panel
- Reading Indications from the PC with DIGSI 5
- SIPROTEC 5 Displaying Indications
- SIPROTEC 5 Operational Log
- SIPROTEC 5 Fault Log
- Switching-Device Log in SIPROTEC 5
- Ground-Fault Log in SIPROTEC 5
- Setting-History Log in SIPROTEC 5
- User Log in SIPROTEC 5
- Security Log in SIPROTEC 5
- Device-Diagnosis Log in SIPROTEC 5
- Communication Log in SIPROTEC 5
- Communication-Supervision Log in SIPROTEC 5
- Motor-Starting Log in SIPROTEC 5
- SIPROTEC 5 Saving and Deleting the Logs
- Spontaneous Indication Display in DIGSI5
- Spontaneous Fault Display on the On-Site Operation Panel
- Stored Indications in the SIPROTEC 5 Device
- Resetting Stored Indications of the Function Group
- Test Mode and Influence of Indications on Substation Automation Technology
- Changing the Transformation Ratios of the Transformer on the Device
System Functions
- SIPROTEC 5 Sampling-Frequency Tracking and Frequency Tracking Groups
- DIGSI5 Text Structure and Reference Number for Settings and Indications
- Processing Quality Attributes
- Protection Communication
- Date and Time Synchronization
- User-Defined Objects in DIGSI5
- SIPROTEC 5 Device Settings
- SIPROTEC 5 Data Types
- Function Control
- Connection Examples
- Chatter blocking
- Settings-Group Switching
Function Groups
- SIPROTEC 5 Voltage current 3-Phase
- SIPROTEC 5 Circuit-breaker
- Process Monitor
- Voltage-current 1-phase
- Motor
- Line Function Groups
- Voltage 3-Phase Function Groups
- Analog Units Function Groups
- User-Defined Function Group
- Recording in SIPROTEC 5
- Motor Monitor
- Current-Flow Criterion
- Circuit-Breaker Condition for the Motor
- Closure Detection Function Groups
- Motor-State Detection
- Cold-Load Pickup Detection
- Thermal Replica Rotor
- Capacitor Bank Function Groups
Functions and Settings
- Power-System Data
- Overcurrent Protection, Phases
- Overcurrent Protection, Ground
- Line Differential Protection
- Stub Differential Protection
- Restricted Ground-Fault Protection
- Distance Protection with Reactance Method (RMD)
- Distance Protection with Classic Method
- Impedance Protection
- Power-Swing Blocking
- Teleprotection with Distance Protection
- Universal Teleprotection with Distance Protection
- Ground-Fault Protection for High-Resistance Ground Faults in Grounded Systems
- Teleprotection with Ground-Fault Protection
- Universal Teleprotection with Ground-Fault Protection
- Echo and Tripping in the Event of Weak Infeed 874
- Tripping with Missing or Weak Infeed According to French Specification
- External Trip Initiation
- Automatic Reclosing Function
- Directional Overcurrent Protection, Phases
- Positive-Sequence Overcurrent Protection
- Instantaneous High-Current Tripping
- Group Indications of Overcurrent Protection Functions
- Overcurrent Protection, 1-Phase
- Voltage-Dependent Overcurrent Protection, Phases
- Sensitive Ground-Fault Detection
- Non-Directional Intermittent Ground-Fault Protection
- Directional Intermittent Ground-Fault Protection
- Negative-Sequence Protection
- Directional Negative-Sequence Protection with Current-Independent Time Delay
- Undercurrent Protection
- Overvoltage Protection with 3-Phase Voltage
- Overvoltage Protection with Positive-Sequence Voltage
- Overvoltage Protection with Negative-Sequence Voltage
- Overvoltage Protection with Positive-Sequence Voltage and Compounding
- Overvoltage Protection with Zero-Sequence Voltage/Residual Voltage
- Overvoltage Protection with Any Voltage
- Undervoltage Protection with 3-Phase Voltage
- Undervoltage Protection with Positive-Sequence Voltage
- Undervoltage Protection with Any Voltage
- Rate-of-Voltage-Change Protection
- Undervoltage-Controlled Reactive-Power Protection
- Voltage-Comparison Supervision
- Fault Locator
- Fault Locator Plus
- Over frequency Protection
- Under frequency Protection
- Rate of Frequency Change Protection
- Under frequency Load Shedding
- Phase-Sequence Switchover
- Instantaneous Tripping at Switch onto Fault
- Thermal Overload Protection, 3-Phase – Advanced
- Thermal Overload Protection, 1-Phase
- Temperature Supervision
- Circuit-Breaker Failure Protection
- Circuit-Breaker Restrike Protection
- Out-of-Step Protection
- Inrush-Current and 2nd Harmonic Detection
- Power Protection (P, Q), 3-Phase
- Current-Jump Detection
- Voltage-Jump Detection
- Vector-Jump Protection
- Arc Protection
- Voltage Measuring-Point Selection
- Current-Unbalance Protection for Capacitors, 1-Phase
- Peak Overvoltage Protection for Capacitors
- Motor-Starting Time Supervision
- Motor Restart Inhibit
- Load-Jam Protection Motor
- Thermal Overload Protection, Rotor
Functional Tests
- Direction Test of the Phase Quantities
- Functional Test Protection Communication
- Functional Test of the Line Differential Protection
- Functional Test for Overvoltage Protection with Zero-Sequence Voltage/Displacement Voltage
- Primary and Secondary Tests of the Circuit-Breaker Failure Protection
- Circuit-Breaker Test
- Out-of-Step Protection Function Test
- Functional Test of the Inrush-Current Detection
- Functional Test of the Trip-Circuit Supervision
- Power-Swing Blocking Functional Test
- Functional Test for the Phase-Rotation Reversal
- Functional Test for Overvoltage Protection with Zero-Sequence Voltage/Residual Voltage
- Directional Testing for Isolated or Resonant-Grounded Systems
- Primary and Secondary Testing of the Synchronization Function
- Commissioning Hints for Voltage Control
- Resource-Consumption Supervision
IEC 61850
- External Signals
- Quality Processing/Affected by the User for Received GOOSE Values
- Quality Processing/Affected by the User in CFC Charts
- Quality Processing/Affected by the User in Internal Device Functions