Skip to main content

Course Title & Dates

  • Config and testing of the generator, transformer, line, and motor protection functions
  • 4 days

Trainer Profile

Registration

email: saeed61850@gmail.com

Tentative Course Schedule

Day 1
  TIME  TRAINING SCHEDULE & TOPICS

    9.00am – 10.30amABB relays PCM 600 installation Connectivity pack installation Hardware configuration Application configuration Signal matrix Parameter setting IED read and write IED online monitoring and signal monitoring Disturbance and event viewer
10.30 am – 10.45 amTEA BREAK
  10.45am – 1.00pm  SIPROTEC 5 relay families and applications DIGSI 5 and device driver installation SIPROTEC 5 configurator Relay configuration
1.00pm – 2.00pmLUNCH
    2.00pm – 3.30pm    SIPROTEC 4 Relay families DIGSI 4 installation Masking I/O CFC Fault Recorder
3.30pm – 3.45pmTEA BREAK
    3.45pm – 5.00pm    MiCOM relays range, naming, and application Easergy software Configuration and PSL Event and disturbance recorder

Day 2

  TIME  TRAINING SCHEDULE & TOPICS

    9.00am – 10.30am    OMICRON CMC Test universe softwareAMT105  AMPro software signal view, impedance view, vector view different types of test modulesRIO, XRIO, and PTL
10.30 am – 10.45 amTEA BREAK
    10.45am – 1.00pm        Principle of Differential Protection87G Generator Differential Protection87T Trans. Differential Protection87M Motor Differential Protection87L Line Differential Protection
1.00pm – 2.00pmLUNCH
    2.00pm – 3.30pm    Testing of the Differential protection function (87G, 87T, 87M, 87L)Operating CharacteristicDifferential ConfigurationDifferential trip timeHarmonic
3.30pm – 3.45pmTEA BREAK
    3.45pm – 5.00pm    81O Over frequency Protection81U Under frequency Protection59 Overvoltage Protection27 Under voltage ProtectionTesting of the Over/under frequency (81O/ 81U)Testing of the Over/Under voltage (59, 27)
contact us to reserve your seat

Day 3

  TIME  TRAINING SCHEDULE & TOPICS

    9.00am – 10.30am    50/51 Overcurrent protection50N/51N earth fault protection67/67N Directional / directional earth fault protectionRelay coordination
10.30 am – 10.45 amTEA BREAK
    10.45am – 1.00pm        Overcurrent test moduleOvercurrent RIO blockSettings of the Overcurrent test moduleTesting of the Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)
1.00pm – 2.00pmLUNCH
    2.00pm – 3.30pm    46 Negative Phase Sequence Protection51V Voltage-Dependent O/C Protection49S Stator Overload Protection49R Overload Protection48 Motor starting time supervision51L lock rotor
3.30pm – 3.45pmTEA BREAK
    3.45pm – 5.00pm    Testing of the Negative Phase Sequence ProtectionTesting of the ANSI 51V Voltage-Dependent O/C ProtectionTesting of the ANSI 49 Overload Protection


Day 4

  TIME  TRAINING SCHEDULE & TOPICS

  9.00am – 10.30am  Distance protection line simulation in PSCADTesting of the fault location function
10.30 am – 10.45 amTEA BREAK
    10.45am – 1.00pm      21 Line distance protection40G Field Failure Protection21G Generator Under impedance Protection78 Pole Slipping Protection
1.00pm – 2.00pmLUNCH
    2.00pm – 3.30pm    Distance RIO block shot Test, Check Test, Search Test, Z\t Diagram, Zone SettingsTesting of the Distance function (21)Testing of the 40G Field Failure Protection
3.30pm – 3.45pmTEA BREAK
    3.45pm – 5.00pm    64S Generator 95%&100% Stator Earth Fault Protection51/27 Generator Dead Machine Protection24G Generator Over flux Protection47G Generator Fuse Failure Supervision32R Generator Reverse Power Protection


Have you ever been looking for comprehensive training, but you get confused & waste your time by not finding useful content?

Don’t worry because we’ve collected and added 5 hours of helpful supplementary videos to the main course too, So you won’t miss anything important. Just recommended to watch the attached videos first, then start the PSCAD main course.

  • Language: English
  • Main course length: 4 hrs
  • Trainer: Dr. Saeed Roostaee (Profile)
  • Format: Pre-Recorded Video with online access
  • Lifetime access
  • Certificate
  • Continous update
  • The training link and activation code will be sent to your email immediately after payment

Download PSCAD Training Package

Pack Details:

Part 1: This part consists of 4 sections and the total length is 40 minutes. In this part, a simple three-phase AC system is simulated. Different elements and their parameters are explained in detail.

Part 2: This part consists of 4 sections and the total length is 41 minutes. A distance protection scheme is presented in detail.

Part 3: This part consists of 2 sections and the total length is 32 minutes. This part presents the Digital fault recorder in PSCAD and how to config the recorded signals in a fault analysis tool (SIGRA).

Part 4: This part consists of 2 sections and the total length is 16 minutes. several relay study cases.

Part 5: This part consists of 5 sections and the total length is 92 minutes & presents the impedance-based fault location function and how to test this function in a relay. Both single end and double end methods are explained and the process of testing this function using PSCAD, SIGRA are presented in detail. An experimental study has been carried out where several faults in different locations are simulated in PSCAD, The Comtrade file of each is loaded in the Omicron test universe and the associated voltage and current are injected into the SEL 421(Distance relay) to test the relay fault location.

Download: Click here

Standard Tower is selected and modeled in the PSCAD

Standard conductors are selected
line parameters are calculated with different methods
Testing of a relay fault location is presented
Single-end and double end fault location methods are presented
Modeling of a simple distance protection scheme is presented

Download: Click here

Certificates For PSCAD Learners

  1. F 1000: Click here to download
  2. F 1001: Click here to download
  3. F 1002: Click here to download
  4. F 1003: Click here to download
  5. F 1004: Click here to download
  6. F 1005: Click here to download
  7. F 1006: Click here to download
  8. F 1007: Click here to download
  9. F 1008: Click here to download
  10. F 1009: Click here to download
  11. F 1010: Click here to download
  12. F 1011: Click here to download
  13. F 1012: Click here to download
  14. F 1013: Click here to download
  15. F 1014: Click here to download
  16. F 1015: Click here to download
  17. F 1016: Click here to download
  18. F 1017: Click here to download
  19. F 1018: Click here to download
  20. F-1019: Click here to download
  21. F-1020: Click here to download
  22. F-1021: Click here to download
  23. F-1022: Click here to download
  24. F-1023: Click here to download
  25. F-1024: Click here to download
  26. F-1025: Click here to download
  27. F-1026: Click here to download
  28. F-1027: Click here to download
  29. F-1028: Click here to download
  30. F-1029: Click here to download
  31. F-1030: Click here to download
  32. F-1031: Click here to download
  33. F-1032: Click here to download
  34. F-1033: Click here to download
  35. F-1034: Click here to download
  36. F-1035: Click here to download
  37. F-1036: Click here to download
  38. F-1037: Click here to download
  39. F-1038: Click here to download
  40. F-1039: Click here to download
  41. F-1040: Click here to download
  42. F-1041: Click here to download
  43. F-1042: Click here to download
  44. F-1043: Click here to download
  45. F-1044: Click here to download
  46. F-1045: Click here to download
  47. F-1046: Click here to download
  48. F-1047: Click here to download
  49. F-1048: Click here to download
  50. F-1049: Click here to download
  51. F-1050: Click here to download
  52. F-1051: Click here to download