Skip to main content

Course Title & Dates

  • Config and testing of the generator, transformer, line, and motor protection functions
  • 4 days

Trainer Profile

Registration

email: saeed61850@gmail.com

Tentative Course Schedule

Day 1
  TIME 

TRAINING SCHEDULE & TOPICS

9.00am – 10.30amABB relays, PCM 600 installation, Connectivity pack installation, Hardware configuration, Application configuration, Signal matrix Parameter setting, IED read and write IED online monitoring and signal monitoring Disturbance, and event viewer
10.30 am – 10.45 amTEA BREAK
10.45am –1.00pm  SIPROTEC 5 relay families and applications DIGSI 5 and device driver installation SIPROTEC 5 configurator Relay configuration
1.00pm – 2.00pmLUNCH
2.00pm –3.30pm    SIPROTEC 4 Relay families DIGSI 4 installation Masking I/O CFC Fault Recorder
3.30pm – 3.45pmTEA BREAK
3.45pm – 5.00pm    MiCOM relays range, naming, and application Easergy Software Configuration and PSL Event and disturbance recorder

Day 2

  TIME 

TRAINING SCHEDULE & TOPICS

9.00am – 10.30am    OMICRON CMC Test universe softwareAMT105  AMPro software signal view, impedance view, vector view different types of test modulesRIO, XRIO, and PTL
10.30 am10.45 amTEA BREAK
10.45am – 1.00pm        Principle of Differential Protection87G Generator Differential Protection87T Trans. Differential Protection87M Motor Differential Protection87L Line Differential Protection
1.00pm – 2.00pmLUNCH
 2.00pm – 3.30pm    Testing of the Differential protection function (87G, 87T, 87M, 87L) Operating CharacteristicDifferential ConfigurationDifferential trip time-harmonic
3.30pm – 3.45pmTEA BREAK
3.45pm – 5.00pm    81O Over frequency Protection81U Under frequency Protection59 Overvoltage Protection27 Under voltage ProtectionTesting of the Over/under frequency (81O/ 81U)Testing of the Over/Under voltage (59, 27)
contact us to reserve your seat

Day 3

  TIME 
TRAINING SCHEDULE & TOPICS

    9.00am – 10.30am    50/51 Overcurrent protection50N/51N earth fault protection 67/67N Directional/ directional earth fault protectionRelay coordination
10.30 am – 10.45 amTEA BREAK
    10.45am – 1.00pm        Overcurrent test moduleOvercurrent RIO block settings of the Overcurrent test module testing of the Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)
1.00pm – 2.00pmLUNCH
2.00pm – 3.30pm    46 Negative Phase Sequence Protection51V Voltage-Dependent O/C Protection49S Stator Overload Protection49R Overload Protection48 Motor starting time supervision51L lock rotor
3.30pm – 3.45pmTEA BREAK
 3.45pm – 5.00pm    Testing of the Negative Phase Sequence ProtectionTesting of the ANSI 51V Voltage-Dependent O/C ProtectionTesting of the ANSI 49 Overload Protection


Day 4

  TIME 
TRAINING SCHEDULE & TOPICS

9.00am – 10.30am  Distance protection line simulation in PSCADTesting of the fault location function
10.30 am – 10.45 amTEA BREAK
10.45am – 1.00pm      21 Line distance protection40G Field Failure Protection21G Generator Under impedance Protection78 Pole Slipping Protection
1.00pm – 2.00pmLUNCH
 2.00pm – 3.30pm    Distance RIO block shot Test, Check Test, Search Test, Z\t Diagram, Zone SettingsTesting of the Distance function (21)Testing of the 40G Field Failure Protection
3.30pm – 3.45pmTEA BREAK
 3.45pm – 5.00pm    64S Generator, 95% &100% Stator Earth Fault Protection, 51/27 Generator, Dead Machine Protection, 24G Generator, Over flux Protection, 47G Generator, Fuse Failure Supervision, 32R Generator, Reverse Power Protection

Have you ever been looking for comprehensive training, but you get confused & waste your time by not finding useful content?

Don’t worry because we’ve collected and added 5 hours of helpful supplementary videos to the main course too, So you won’t miss anything important. Just recommended to watch the attached videos first, then start the PSCAD main course.

  • Language: English
  • Main course length: 4 hrs
  • Trainer: Dr. Saeed Roostaee (Profile)
  • Format: Pre-Recorded Video with online access
  • Lifetime access
  • Certificate
  • Continous update
  • The training link and activation code will be sent to your email immediately after payment

Pack Details:

Part 1: In this part, a simple three-phase AC system is simulated. Different elements and their parameters are explained in detail. (4 sections, 40 minutes)

Part 2: A distance protection scheme is presented in detail. (4 sections, 41 minutes)

Part 3:This part presents the Digital fault recorder in PSCAD and how to config the recorded signals in a fault analysis tool (SIGRA). (2 sections, 32 minutes)

Part 4: several relay study cases. (2 sections,16 minutes)

Part 5: The impedance-based fault location function and how to test this function in a relay. Both single-end and double-end methods are explained and the process of testing this function using PSCAD, and SIGRA is presented in detail. An experimental study has been carried out where several faults in different locations are simulated in PSCAD. The Comtrade file of each is loaded in the Omicron test universe and the associated voltage and current are injected into the SEL 421 (Distance relay) to test the relay fault location. (5 sections, 92 minutes)

  • The training link and activation number will be sent to your email after the +payment.
Standard Tower is selected and modeled in the PSCAD
Standard conductors are selected
line parameters are calculated with different methods
Testing of a relay fault location is presented
Single-end and double-end fault location methods are presented
Modeling of a simple distance protection scheme is presented

Certificates For PSCAD Learners