Skip to main content

MICOM P123 protection relay has been made to control and protect current and ground faults for overhead and cable lines, and MICOM P441 is one of the distance relays that’s responsible for protection control and monitoring of transmission lines.

Through this course, you can learn how to configure and work with these relays.

  • Online video training
  • Trainer: Dr. Saeed Roostaee (Profile)
  • 4 hrs pre-recorded videos + 4 hrs attached supplementary videos on google drive + data models + PDF files

Part 01: MiCOM relays range, naming, and application

Parts 2-7: exercises with MiCOM P123 and AMT105 setup. Three-phase signals are injected into the relay to test hardware connection and protection functions.

Parts 8-17: exercises with MiCOM P441 and AMT105 (configuration and PSL, event and disturbance recorder, overcurrent protection, voltage protection, negative sequence protection, and distance protection parameters)

Supplementary files attached

  • 01- start working with Easergy Studio in online mode
  • 02- MiCOM Relay Measurements, Event Logs & Disturbance Records
  • 03- Input naming in the Micom relays
  • 04- Communicate with MiCom P139
  • 05- Communicating with MICOM P139 checking the parameters from the front panel
  • 06- Binary input test from MICOM P139 front panel
  • 07- Binary input test from MICOM P139 front Easergy studio
  • 08 Function Parameters in the MICOM P139
  • 09- Overcurrent Function test in the Micom P139
  • 10- Inverse time overcurrent function IDMT test in the MiCOM P139
  • 11- CBF function config and parameters in the Micom P139
  • 12- Autorecoser function config in the MiCOMp139
  • 13- Autorecoser function test in the MiCOMp139
  • 14- Autorecoser function test in the MiCOMp139 By FREJA
  • 15- Under and Over Voltage protection function parameters and testing in the MiCOM P443
  • 16- Overcurrent and Earth Fault protection function parameters and testing in the MiCOM P443
  • 17- DEF protection function parameters and testing in the MiCOM P443
  • 18- Auto recloser function test in the MiCOM P546
  • 19- Trip Scheme in the Micom P546
  • 20- SOTF in the Micom P546
  • 21- MICOM P546 Differential protection test
  • 22- MICOM P546 Syncro Check
MiCOM P123 front panel
Easergy Studio

Certificate of Completion

After activating the MiCOM training pack on your system, we will issue your certificate for the course.

  1. M-1000: Click here to download
  2. M-1001: Click here to download
  3. M-1002: Click here to download
  4. M-1003: Click here to download
  5. M-1004: Click here to download
  6. M-1005: Click here to download
  7. M-1006: Click here to download
  8. M-1007: Click here to download
  9. M-1008: Click here to download
  10. M-1009: Click here to download
  11. M-1010: Click here to download
  12. M-1011: Click here to download
  13. M-1012: Click here to download
  14. M-1013: Click here to download
  15. M-1014: Click here to download
  16. M-1015: Click here to download
  17. M-1016: Click here to download
  18. M-1017: Click here to download
  19. M-1018: Click here to download
  20. M-1019: Click here to download
  21. M-1020: Click here to download
  22. M-1021: Click here to download
  23. M-1022: Click here to download
  24. M-1023: Click here to download
  25. M-1024: Click here to download
  26. M-1025: Click here to download
  27. M-1026: Click here to download
  28. M-1027: Click here to download