Course content:

  • Basics of Synchronous and Asynchronous Motors
  • Motor Nameplate
  • Motor Connections
  • Motor Faults, Faults, and Protection Functions
  • Overview of the Motor Protection Functions
  • Motor Overcurrent Protection
  • Motor Earth fault protection
  • Motor Overload protection
  • Motor Voltage protection
  • Negative Sequence Protection
  • Motor Lock Rotor & Mechanical Jam protection
  • Motor Undercurrent protection


Three-phase induction motors are the most common and frequently encountered machines in the industry

Modern numerical motor relay protection technology must be sufficient to meet the protection requirements of any of the vast range of motor designs. A motor protection relay providing sufficient protection will have the following set of characteristics such as extended start relay protection, loss-of-load relay protection, number of starts limitation, stalling relay protection, short circuit relay protection, thermal relay protection, Earth fault relay protection, negative sequence current detection, winding RTD measurement/trip, under-voltage relay protection, auxiliary supply supervision, …

  • 14 Speed Switch
  • 27 Undervoltage*
  • 37 (P,C) Underpower/Undercurrent
  • 38 Bearing Temperature*
  • 46 Current Unbalance
  • 47 Phase Reversal
  • 49P PTC Overtemperature*
  • 49R RTD Thermal*
  • 49T Thermal Model
  • 50 (P,G,Q) Overcurrent (Phase, Ground, Neg. Seq.)
  • 50P LR Locked Rotor
  • 50P LJ Load Jam
  • 50N Neutral Overcurrent
  • 51 (P,G,Q) Time-Overcurrent (Phase, Residual, Neg. Seq.)
  • 55 Power Factor*
  • 59P Phase Overvoltage*
  • 60 Loss-of-Potential*
  • 66 Starts-Per-Hour
  • 81 (O,U) Over-/Underfrequency
  • 87 Current Differential*
  • 90 (P,I,T) Load Control (Power, Current, Thermal Capacity)
  • 50/51 Adaptive Overcurrent
  • 85 RIO SEL Mirrored Bits® Communications
  • DFR Event Reports—Motor Starts, Motor Operating
  • Statistics
  • ENV Optional SEL-2600 RTD Module*
  • HMI Operator Interface
  • LDP Load Data Profiling
  • LGC SELogic® Control Equations
  • MET Metering
  • RTU Remote Terminal Unit
  • SDTM Slip-Dependent AccuTrackTM Thermal Model
  • SER Sequential Events Recorders
SEL710 Motor Protection Relay
  • Stator overload protection 49
  • Starting time supervision, locked rotor protection 48
  • Restart inhibit 66,49R
  • Negative-sequence current protection I2> 46
  • Thermal unbalanced-load protection I2 2(t) 46
  • Temperature measurement 1 38
  • Undercurrent protection 37
  • Active-power protection (P<) 32U
  • Sensitive ground-fault protection 59N,
  • non-directional 51Ns
  • directional 67Ns
  • Overcurrent protection 50, 51
  • Current-differential protection 87
  • Undervoltage protection 27
  • Overvoltage protection 59
  • Underexcitation protection 40
  • Rotor ground-fault protection 64R
  • Frequency protection 81
  • Circuit-breaker failure protection 50BF
  • User-programmable logic (CFC)
  • Control functionality
  • Graphic display (large)
  • Flexible interfaces
  • Frequency operating range (10 Hz – 70 Hz)
  • Operational measured values and
  • functional measured values
SIPROTEC 5 Motor Protection relays

ABB REM543 and ABB REM545 Motor protection IEDs
  • Three-phase non-directional overcurrent protection, low-stage PHLPTOC 3I> 51P-1
  • Three-phase non-directional overcurrent protection, instantaneous stage PHIPTOC 3I>>> 50P/51P
  • Non-directional earth-fault protection, low-stage EFLPTOC I0> 51N-1
  • Non-directional earth-fault protection, high stage EFHPTOC I0>> 51N-2
  • Non-directional earth-fault protection, instantaneous stage EFIPTOC I0>>> 50N/51N
  • Directional earth-fault protection, low stage DEFLPDEF I0> -> 67N-1
  • Directional earth-fault protection, high stage DEFHPDEF I0>> -> 67N-2
  • Rotor earth-fault protection MREFPTOC Io>R 64R
  • Negative-sequence overcurrent protection for machines MNSPTOC I2>G/M 46G/46M
  • Phase-reversal protection PREVPTOC I2>> 46R
  • Three-phase thermal overload protection for motors MPTTR 3Ith>M 49M
  • Motor startup supervision STTPMSU Is2t n< 48,66,14,51LR Motor load jam protection JAMPTOC Ist> 51LR
  • Emergency start ESMGAPC ESTART ESTART
  • Loss of load supervision LOFLPTUC 3I< 37 High-impedance or flux-balance based differential protection for machines MHZPDIF 3dIHi>G/M 87GH/87MH
  • Stabilized differential protection for machines MPDIF 3dI>G/M 87G/87M
  • Three-phase overvoltage protection PHPTOV 3U> 59
  • Three-phase undervoltage protection PHPTUV 3U< 27 Positive-sequence overvoltage protection PSPTOV U1> 47O+
  • Positive-sequence Undervoltage protection PSPTUV U1< 47U+ Negative-sequence overvoltage protection NSPTOV U2> 47OResidual
  • overvoltage protection ROVPTOV U0> 59G
  • Reverse power/directional overpower protection DOPPDPR P> 32R/32O
  • Frequency gradient protection DAPFRC df/dt> 81R
  • Over frequency protection DAPTOF f> 81O
  • Under frequency protection DAPTUF f< 81U Three-phase underexcitation protection UEXPDIS X< 40 Circuit breaker failure protection CCBRBRF 3I>/I0>BF 51BF/51NBF
  • Tripping logic TRPPTRC I -> O 94
  • Multipurpose analog protection MAPGAPC MAP MAP
  • Bay control QCCBAY CBAY CBAY
  • Interlocking interface SCILO 3 3
  • Circuit breaker/disconnector control GNRLCSWI I <-> O CB/DC I <-> O CB/DC
  • Circuit breaker DAXCBR I <-> O CB I <-> O CB
  • Disconnector DAXSWI I <-> O DC I <-> O DC
  • Local/remote switch interface LOCREM R/L R/L
  • Single point control (8 signals) SPC8GGIO
  • Double point indication DPGGIO
  • Single point indication SPGGIO
  • Generic measured value MVGGIO
  • Logic Rotating Switch for function selection and LHMI presentation SLGGIO
  • Selector mini switch VSGGIO
  • Pulse counter for energy metering PCGGIO
  • Event counter CNTGGIO
  • Supervision and monitoring
  • Runtime counter for machines and devices MDSOPT OPTS OPTM
  • Circuit breaker condition monitoring SSCBR CBCM CBCM
  • Fuse failure supervision SEQRFUF FUSEF 60
  • Current circuit supervision CCRDIF MCS 3I MCS 3I
  • Trip-circuit supervision TCSSCBR TCS TCM
  • Station battery supervision SPVNZBAT U<> U<>
  • Energy monitoring EPDMMTR E E
  • Measured value limit supervision MVEXP
  • Three-phase current measurement CMMXU 3I 3I
  • Three-phase voltage measurement (phase-to-earth)
  • VPHMMXU 3Upe 3Upe
  • Three-phase voltage measurement (phase-to-phase) VPPMMXU 3Upp 3Upp
  • Residual current measurement RESCMMXU I0 I0
  • Residual voltage measurement RESVMMXU U0 U0
  • Power monitoring with P, Q, S, power factor, frequency PWRMMXU PQf PQf
  • Sequence current measurement CSMSQI I1, I2 I1, I2
  • Sequence voltage measurement VSMSQI U1, U2 V1, V2
REM 543 Motor protection relay
GE motor protection relays – SR469, GE 369, GE869
  • Current Protection: Phase Overcurrent (67, 51, 50)
  • Directional Control of Overcurrent Protection (67)
  • Overcurrent Protection (50)
  • Current Protection: Undercurrent (37)
  • Phase Unbalance (46)
  • Time Delayed Overcurrent Protection (51)
  • Current Protection: Measured Earth Fault (50/51G)
  • Directional Control of Measured Earth Fault Protection (67G)
  • Measured Earth Fault Protection (50G)
  • Time Delayed Measured Earth Fault Protection (51G)
  • Current Protection: Derived Earth Fault (50/51N)
  • Directional Control of Derived Earth Fault Protection (67N)
  • Time Delayed Derived Earth Fault Protection (51N)
  • High Impedance Restricted Earth Fault (87REF)
  • Voltage Protection: NPS Overvoltage (47)
  • Earth Fault Protection (50N)
  • Voltage Protection: Under/Over Frequency (81)
  • Power Protection – 32
  • Sensitive Power Protection – 32S
  • Break Capacity Limit (50BCL)
  • Phase Reversal (46 PH REV)
  • Temperature Monitoring
  • CT Supervision (60CTS)
  • Power Factor – 55
  • Trip Circuit Supervision (74TCS)
  • Close Circuit Supervision (74CCS)
  • Circuit Breaker Failure (50BF)
7SR17 Rho Motor Protection Relay

Course Title & Dates

  • Config and testing of the generator, transformer, line, and motor protection functions
  • 4 days

Trainer Profile

Registration

email: saeed61850@gmail.com

Tentative Course Schedule

Day 1
  TIME 

TRAINING SCHEDULE & TOPICS

9.00am – 10.30amABB relays, PCM 600 installation, Connectivity pack installation, Hardware configuration, Application configuration, Signal matrix Parameter setting, IED read and write IED online monitoring and signal monitoring Disturbance, and event viewer
10.30 am – 10.45 amTEA BREAK
10.45am –1.00pm  SIPROTEC 5 relay families and applications DIGSI 5 and device driver installation SIPROTEC 5 configurator Relay configuration
1.00pm – 2.00pmLUNCH
2.00pm –3.30pm    SIPROTEC 4 Relay families DIGSI 4 installation Masking I/O CFC Fault Recorder
3.30pm – 3.45pmTEA BREAK
3.45pm – 5.00pm    MiCOM relays range, naming, and application Easergy Software Configuration and PSL Event and disturbance recorder

Day 2

  TIME 

TRAINING SCHEDULE & TOPICS

9.00am – 10.30am    OMICRON CMC Test universe softwareAMT105  AMPro software signal view, impedance view, vector view different types of test modulesRIO, XRIO, and PTL
10.30 am10.45 amTEA BREAK
10.45am – 1.00pm        Principle of Differential Protection87G Generator Differential Protection87T Trans. Differential Protection87M Motor Differential Protection87L Line Differential Protection
1.00pm – 2.00pmLUNCH
 2.00pm – 3.30pm    Testing of the Differential protection function (87G, 87T, 87M, 87L) Operating CharacteristicDifferential ConfigurationDifferential trip time-harmonic
3.30pm – 3.45pmTEA BREAK
3.45pm – 5.00pm    81O Over frequency Protection81U Under frequency Protection59 Overvoltage Protection27 Under voltage ProtectionTesting of the Over/under frequency (81O/ 81U)Testing of the Over/Under voltage (59, 27)
contact us to reserve your seat

Day 3

  TIME 
TRAINING SCHEDULE & TOPICS

    9.00am – 10.30am    50/51 Overcurrent protection50N/51N earth fault protection 67/67N Directional/ directional earth fault protectionRelay coordination
10.30 am – 10.45 amTEA BREAK
    10.45am – 1.00pm        Overcurrent test moduleOvercurrent RIO block settings of the Overcurrent test module testing of the Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)
1.00pm – 2.00pmLUNCH
2.00pm – 3.30pm    46 Negative Phase Sequence Protection51V Voltage-Dependent O/C Protection49S Stator Overload Protection49R Overload Protection48 Motor starting time supervision51L lock rotor
3.30pm – 3.45pmTEA BREAK
 3.45pm – 5.00pm    Testing of the Negative Phase Sequence ProtectionTesting of the ANSI 51V Voltage-Dependent O/C ProtectionTesting of the ANSI 49 Overload Protection


Day 4

  TIME 
TRAINING SCHEDULE & TOPICS

9.00am – 10.30am  Distance protection line simulation in PSCADTesting of the fault location function
10.30 am – 10.45 amTEA BREAK
10.45am – 1.00pm      21 Line distance protection40G Field Failure Protection21G Generator Under impedance Protection78 Pole Slipping Protection
1.00pm – 2.00pmLUNCH
 2.00pm – 3.30pm    Distance RIO block shot Test, Check Test, Search Test, Z\t Diagram, Zone SettingsTesting of the Distance function (21)Testing of the 40G Field Failure Protection
3.30pm – 3.45pmTEA BREAK
 3.45pm – 5.00pm    64S Generator, 95% &100% Stator Earth Fault Protection, 51/27 Generator, Dead Machine Protection, 24G Generator, Over flux Protection, 47G Generator, Fuse Failure Supervision, 32R Generator, Reverse Power Protection

20 WhatsApp Groups for protection engineers to join:

  • WhatsApp Grp 01: Protection Relay – General
  • WhatsApp Grp 02: Substation Automation – General
  • WhatsApp Grp 03: Transmission line protection
  • WhatsApp Grp 04: Transformer protection
  • WhatsApp Grp 05: Motor protection
  • WhatsApp Grp 06: Generator protection
  • WhatsApp Grp 07: Overcurrent and Earth Fault Protection
  • WhatsApp Grp 08: Busbar protection and Bay controller
  • WhatsApp Grp 09: Breaker protection and control
  • WhatsApp Grp 10: Protection Relay Testing and commissioning
  • WhatsApp Grp 11: DIgSILENT
  • WhatsApp Grp 12: ETAP
  • WhatsApp Grp 13: PSCAD
  • WhatsApp Grp 14: IEC 61850 configuration
  • WhatsApp Grp 15: Switchgear GIS & AIS
  • WhatsApp Grp 16: GE Relay Configuration
  • WhatsApp Grp 17: SIEMENS Relay configuration
  • WhatsApp Grp 18: Schnider Relay configuration
  • WhatsApp Grp 19: SEL Relay Configuration
  • WhatsApp Grp 20: ABB Relion configuration

Click here to join these groups

Please send the group’s numbers which you are interested in on WhatsApp. number : +989129613659

7