Skip to main content

Content:

Supplementary Files: The important related files/ videos /software and attached to the course as extra files.

Any queries, please feel free to contact me at: saeed61850@gmail.com

Part A: Introduction, general settings, Hardware & connection, Impedance/Vector/report View, the test object, …

  • A 01 (Length: 02 min, Update: Oct 3, 2021): Introduction
  • A 02 (Length: 05 min, Update: Oct 3, 2021): Strat page (Omicron)
  • A 03 (Length: 06 min, Update: Oct 3, 2021): General settings (Omicron)
  • A 04 (Length: 05 min, Update: Oct 3, 2021): Strat page (Vebko)
  • A 05 (Length: 14 min, Update: Oct 3, 2021): Phasor view, Impedance view (Omicron)
  • A 06 (Length: 06 min, Update: Oct 3, 2021): Phasor view, Impedance view, differential view (Vebko)
  • A 07 (Length: 04 min, Update: Oct 3, 2021): Hardware connection
  • A 08 (Length: 10 min, Update: Oct 3, 2021): Practical section with Omicron 256 plus, SEL 421

Part B: Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)

  • B 01 (Length: 19 min, Update: Oct 3, 2021): Test object, Overcurrent RIO block, testing of overcurrent
  • B 02 (Length: 16 min, Update: Oct 3, 2021): Settings of the Overcurrent test module
  • B 03 (Length: 15 min, Update: Oct 3, 2021): Practical section
  • B 04 (Length: 17 min, Update: Oct 3, 2021): Practical section
  • B 05 (Length: 06 min, Update: Oct 3, 2021): Practical section
  • B 06 (Length: 15 min, Update: Oct 3, 2021): Practical section
  • B 07 (Length: 09 min, Update: Oct 3, 2021): Practical section
  • B 08 (Length: 15 min, Update: Oct 3, 2021): Practical section
  • B 09 (Length: 22 min, Update: Oct 3, 2021): Practical section
  • B 10 (Length: 23 min, Update: Oct 3, 2021): Practical section (directional overcurrent concepts, settings, practice)
  • B 11 (Length: 06 min, Update: Oct 3, 2021): Practical section (directional overcurrent testing)

Part C: Differential Protection Functions (87G, 87T, 87L)

  • C 01 (Length: 03 min, Update: Oct 27, 2021): Diff protection principal
  • C 02 (Length: 11 min, Update: Oct 27, 2021): Diff parameters
  • C 03 (Length: 12 min, Update: Oct 27, 2021): Diff RIO block
  • C 04 (Length: 05 min, Update: Oct 27, 2021): Diff configuration
  • C 05 (Length: 07 min, Update: Oct 27, 2021): Diff Operating Characteristic
  • C 06 (Length: 12 min, Update: Oct 27, 2021): Diff Trip Time Characteristic & Diff Harmonic Restraint

Part D: XRIO and PTL

  • D 01 (Length: 13 min, Update: Nov 13, 2021): RIO and XRIO history and why we should use this format for relay testing, RIO structure, XRIO structure, Differences between RIO and XRIO files, XRIO features & benefits, LinkToXRIO
  • D 02 (Length: 05 min, Update: Nov 13, 2021): XRIO template, How to Import Relay Settings, How to find a proper XRIO template and filter based on the relay
  • D 03 (Length: 08 min, Update: Nov 13, 2021): Common problems while loading the relay settings into a template and how to solve the issues, XRIO template based on the relay versions
  • D 04 (Length: 06 min, Update: Nov 13, 2021): Explain a case study XRIO file
  • D 05 (Length: 10 min, Update: Nov 13, 2021): Modify a case study XRIO file
  • D 06 (Length: 09 min, Update: Nov 13, 2021): Modify the XRIO template, RIO blocks

Part E: Impedance Protection Functions

  • E 01 (Length: 09 min, Update: Nov 26, 2021): Distance RIO block
  • E 02 (Length: 07 min, Update: Nov 26, 2021): Advance Distance Test Module settings
  • E 03 (Length: 08 min, Update: Nov 26, 2021): Distance protection function principal, Impedance View
  • E 04 (Length: 18 min, Update: Nov 26, 2021): Analysis of several faults visually in the impedance view
  • E 05 (Length: 19 min, Update: Nov 26, 2021): Analysis of several distance relays (RAZOA, ABB REL670, SEL421, Siemens 7SA8x, MiCOM P442, NR PCS 931S, Protecta)
  • E 06 (Length: 08 min, Update: Nov 26, 2021): Distance Test Module settings
  • E 07 (Length: 12 min, Update: Nov 26, 2021): Preparing XRIO file for testing of impedance protection functions

Part F: Autoreclosure Function (ANSI 79)

  • F 01 (Length: 04 min, Update: Dec 03, 2021): Autoreclosure Description, auto reclose process
  • F 02 (Length: 05 min, Update: Dec 03, 2021): Autoreclosure settings, Autoreclose timing diagram
  • F 03 (Length: 11 min, Update: Dec 03, 2021): Autoreclosure simulation
  • F 04 (Length: 12 min, Update: Dec 03, 2021): Testing of AR in state sequencer
  • F 05 (Length: 09 min, Update: Dec 03, 2021): Testing of AR in the Autorecoser test module

Part G: Voltage and Frequency Protection Functions (ANSI 27, ANS59, ANSI81O, 81U)

  • G 01 (Length: 06 min, Update: Dec 08, 2021): Ramping test modules and testing the frequency functions
  • G 02 (Length: 05 min, Update: Dec 08, 2021): Paulse ramping test module
  • G 03 (Length: 06 min, Update: Dec 08, 2021): Continous ramp and step ramp
  • G 04 (Length: 11 min, Update: Dec 08, 2021): How to test Over/Under voltage protection functions (59, 27)

Part H: Study functions, testing, and commission of SIPROTEC 7UT6

  • H 01 (Length: 10 min, Update: Dec 20, 2021): SIPROTEC 7UT6 setting description and configuration
  • H 02 (Length: 14 min, Update: Dec 20, 2021): How to test differential function in SIPROTEC 7UT6, No combined characteristic feature, Automate testing by creating SIEMENS 7UT XRIO file
  • H 03 (Length: 18 min, Update: Jan 01, 2022): The procedure of testing transformer protection with Quick CMC

Part K: Study functions, testing, and commission of MiCOM P44x

  • K 01 (Length: 19 min, Update: Oct 31, 2022): Hardware and function description of the MiCOM P441, P442 & P444
  • K 02 (Length: 17 min, Update: Oct 31, 2022): MiCOM Relay connections, communication, and Wire connection test
  • K 03 (Length: 05 min, Update: Nov 1, 2022): Distance protection parameters and testing
  • K 04 (Length: 10 min, Update: Nov 1, 2022): Switch on to fault protection (SOTF) function parameters and testing
Testing and Commissioning of Protective Relays Training

  • Introduction, Software Installation, and general settings
  • Different types of test modules
  • Impedance/Vector/report View, Display settings
  • Test Object, Hardware Configuration
  • RIO, XRIO, and PTL
  • Control Center, How to create and modify XRIO/ PTL files
  • Transient module, Advanced transplay
  • RIO Function Over Current, Define Element Characteristic, Pick-Up/ Drop-Off Test
  • Testing of the Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)
  • Distance Configuration, Settings, Shot Test, Check Test, Search Test, Z\t Diagram, Zone Settings
  • Testing of the Distance function (21)
  • Principle of Differential Protection, Operating Characteristic, Differential Configuration, Differential Operating Characteristic, Differential Trip Time, and Harmonic Restraint
  • Testing of the Differential protection function (87, 87G, 87T)
  • Testing of the Power swing function
  • Autoreclosure, shot and times, unsuccessful / Successful Sequence
  • Testing of the Autorecloser function
  • Testing of the Fault location function
  • Testing of the Over/Under frequency (81O/ 81U)
  • Testing of the Over/Undervoltage (59, 27)
  • Testing of the Pole-Slip function (78)
  • Testing of the Loss of Excitation (40)
  • Testing of the Negative Phase Sequence (46)
  • Testing of the Overload (49)
  • How to test the distance function if the distance module is deactivated in the test universe software
  • How to test differential function if the differential module is deactivated in the test universe
  • Practical sections with testing of the relays (ABB REG670, MiCOM P441, MiCOM P123, …)
Training on Testing and commissioning by Dr. Saeed Roostaee
This image has an empty alt attribute; its file name is IMG_20210517_150836.jpg

The testing & commissioning of the protection relays can be done by different testing software and hardware. In this training, we have used OMICRON Test universe, Vebko AMpro, and FREJA win.

  1. T 1000: Click here to download
  2. T 1001: Click here to download
  3. T 1002: Click here to download
  4. T 1003: Click here to download
  5. T 1004: Click here to download
  6. T 1005: Click here to download
  7. T 1006: Click here to download
  8. T 1007: Click here to download
  9. T 1008: Click here to download
  10. T 1009: Click here to download
  11. T 1010: Click here to download
  12. T 1011: Click here to download
  13. T 1012: Click here to download
  14. T 1013: Click here to download
  15. T 1014: Click here to download
  16. T 1015: Click here to download
  17. T 1016: Click here to download
  18. T 1017: Click here to download
  19. T 1018: Click here to download
  20. T 1019: Click here to download
  21. T 1020: Click here to download
  22. T 1021: Click here to download
  23. T 1022: Click here to download
  24. T 1023: Click here to download
  25. T 1024: Click here to download
  26. T 1025: Click here to download
  27. T 1026: Click here to download
  28. T 1027: Click here to download
  29. T 1028: Click here to download
  30. T 1029: Click here to download
  31. T 1030: Click here to download
  32. T 1031: Click here to download
  33. T 1032: Click here to download
  34. T 1033: Click here to download
  35. T 1034: Click here to download
  36. T 1035: Click here to download
  37. T 1036: Click here to download
  38. T 1037: Click here to download
  39. T 1038: Click here to download
  40. T 1039: Click here to download
  41. T 1040: Click here to download
  42. T 1041: Click here to download
  43. T 1042: Click here to download
  44. T 1043: Click here to download
  45. T 1044: Click here to download
  46. T 1045: Click here to download
  47. T 1046: Click here to download
  48. T 1047: Click here to download
  49. T 1048: Click here to download
  50. T 1049: Click here to download
  51. T 1050: Click here to download