Skip to main content

In this package, all the training courses (DIGSI 4, DIGSI 5, ETAP, DIGSI 4, DIGSI 5, ETAP, PSCAD, IEC 61850, PCM 600, Micom, and Testing Commissioning, Generator Protection, DigSilent, Busbar protection) are gathered. So You can save your money by taking all courses in one pack. Our courses aren’t time-limited and you have access to them at any time. The training link and activation number will be sent to your email immediately after payment.

The details and Demos of each course are placed below and if you need further information, please feel free to contact us.

Product Detail:

PSCAD Demo

IEC 61850 Demo & items

ETAP Demo & items

ABB PCM 600 Demo & items

DIGSI 4 Demo & items

DIGSI 5 Demo & items

Have you ever been looking for comprehensive training, but you get confused & waste your time by not finding useful content?

Don’t worry because we’ve collected and added 5 hours of helpful supplementary videos to the main course too, So you won’t miss anything important. Just recommended to watch the attached videos first, then start the PSCAD main course.

  • Language: English
  • Main course length: 4 hrs
  • Trainer: Dr. Saeed Roostaee (Profile)
  • Format: Pre-Recorded Video with online access
  • Lifetime access
  • Certificate
  • Continous update
  • The training link and activation code will be sent to your email immediately after payment

Pack Details:

Part 1: In this part, a simple three-phase AC system is simulated. Different elements and their parameters are explained in detail. (4 sections, 40 minutes)

Part 2: A distance protection scheme is presented in detail. (4 sections, 41 minutes)

Part 3:This part presents the Digital fault recorder in PSCAD and how to config the recorded signals in a fault analysis tool (SIGRA). (2 sections, 32 minutes)

Part 4: several relay study cases. (2 sections,16 minutes)

Part 5: The impedance-based fault location function and how to test this function in a relay. Both single-end and double-end methods are explained and the process of testing this function using PSCAD, and SIGRA is presented in detail. An experimental study has been carried out where several faults in different locations are simulated in PSCAD. The Comtrade file of each is loaded in the Omicron test universe and the associated voltage and current are injected into the SEL 421 (Distance relay) to test the relay fault location. (5 sections, 92 minutes)

  • The training link and activation number will be sent to your email after the +payment.
Standard Tower is selected and modeled in the PSCAD
Standard conductors are selected
line parameters are calculated with different methods
Testing of a relay fault location is presented
Single-end and double-end fault location methods are presented
Modeling of a simple distance protection scheme is presented

Certificates For PSCAD Learners