- Course Name: SIEMENS SAS
- Pre-requisite training: DIGSI 4, DIGSI 5, IEC61850
- Language: English
- + Supporting Files
- + Certificate of completion
- Delivery: Face-to-face / Online
- Duration: 8 Days
- Trainer: Dr. Saeed Roostaee (Profile)
Substation Automation System
- Substation Automation System-an overview
- SIEMENS SAS In the past
- SIEMENS SAS Nowadays
- Network Theory (Types of Communications, Data Transmission Types, MAC Address, IP Address, Subnet Mask)
- Fundamentals of Communication Via Ethernet Various Topologies
- Ethernet and IEC 61850 Concepts (The EN100 Communication Module, Time Server, Switch, Network Card)
- Important Factors for Choosing a Topology
- Star Topology
- Ring Topology
Hardware
- RUGGEDCOM Ethernet Switch RS900
- RUGGEDCOM Ethernet Switch RS8000
- RUGGEDCOM Ethernet Switch RSG2100
- SIPROTEC Communication Modules
- Hirschmann Switches
- Siemens Scalance – Switches
- Modems
- I/O-Box 6MD61
- Bay Controller 6MD66
- Transformer Regulators
- SICAM 1703 device series – TM 1703 mic
- SICAM 1703 device series – TM 1703 ACP
- SICAM 1703 device series – BC 1703 ACP
- SICAM 1703 device series – AK 1703 ACP
- Siemens Serial Modem 7XV5655
- Siemens converter – Mini star coupler
- Com-Expander: Comtrol Rocket Port
- Operator Desk / Engineering PCs
- Time receiver
- external time masters
- NTP-time synchronization with SICLOCK
- Modem Splitter
- Station Unit 6MD9101
- SICAM PAS Station Unit
Bay Level Engineering (IEC 61850 and Modbus)
- Sample IEC 81850 Configuration
- Setting the Network Parameters for Ethernet Switches
- Modbus Connection of Measuring Centers
- Serial/Ethernet Converter (7XV5655)
- GPS Satellite Clock
- IEC 61850 – The Configuration Language SCL File Types at a glance
- ICD file – IED Capability Description
- SSD file – Substation Specification Description
- CID file – Configured IED Description
- SCD file – Substation Configuration Description
- IEC 61850 Services in IEDs and SICAM PAS
- Updating ICD – Files
- IEC 61850 – creating PAS configuration data
- Client/Server Communication
- Publisher / Subscriber Communication
- Logical Node
- Data Objects
- Standardizing Communication with Logical Nodes
- Addressing control of a circuit breaker
- Ethernet switches according to IEC61850 specification
- Ethernet Master clocks
- IEC61850 Engineering
- Process of IEC61850 Engineering
- Diagnosis Tool Networkview
- Diagnosis Tool IEC-Browser
- Config signals in the DIGSI 4 Matrix
- Config signals in the DIGSI 5 IEC61850 structure
- System Configurator in DIGSI
- Assign IEDs to the IEC 61850 Station
- Mapping GOOSE messages
- Updating device parameter files
- IEC 61850 Ethernet Medium: FO Ring
- IEC 61850 Ethernet Configuration: Electrical Star
- IEC 61850 Ethernet FO-Ring with RuggedCom
- IEC 61850 Ethernet FO-Ring with optical EN100
- IEC 61850 Ethernet – Partial Redundant FO-Ring
- IEC 61850 Ethernet – Redundant FO-Ring
- IEC 61850 Ethernet – with redundant PAS
- Sample Real Projects
- Export of Station Information
- Import of SCD-File into the SICAM PAS
Station Level Engineering SICAM PAS
- Introduction to SICAM PAS Automation System
- SICAM PAS Tasks
- Fields of Application
- SICAM PAS Features
- Scalability – Software and Hardware Configuration for Small to Large Applications
- Basic Package “ Full Server”
- Distributed system with higher performance (Full Server + DIP (Device Interface Processor))
- High availability by Redundancy
- High flexibility through further interfaces
- Optional Packages (IEC 61850, Profibus FMS (SICAM/SIPROTEC specified protocols), IEC 60870-5-103, DNP V3.00, Profibus DP, Modbus, ILSA (Internal LSA protocol, OPC-Client, Automation CFC)
- Substation Automation Functions (Control Authority, Bay Blocking, Telecontrol Blocking, Time Synchronization, Fault Recording, Redundancy)
- SICAM PAS in Star Configuration
- SICAM PAS in (Fiber Optic) Ring
- SICAM PAS FO Station LAN
- SICAM PAS Installation
- Licensing
- Licensing With Feature Enabler
- SICAM PAS Basic packet and options
- SICAM PAS Configuration User Administration Tool
- IEC 61850 Services in IEDs and SICAM PAS
- SICAM PAS Configuration (Working with Project Databases, Creating a New Database, Adding and Managing Systems, Adding an Application (IEC 61850 Client), Importing a SCD file, Updating One or Several Device(s), Adding ModbusApplication, Parameterizing ModbusApplication, Added EMA90 ModbusMap, Defining the Device Template (ModbusMap), Adding IEC 60870-5-101 Slave Application, Inserting the Control Center of IEC 60870-5-101 Slave, Inserting the SNMP Application, Monitoring IEC 61850 IEDs Connection Status With SNMP, Inserting a PASCC Application to Full Server System, Inserting Control Center to PASCC Application, Inserting a PASCC to a New System (DIP)
- Creating a Full Server Computer
- Creating an IEC101-Master to connect the RTU
- Importing the RTU file
- Communication IEC 60870-5-103
- Communication OPC-Client (based on COM/DCOM)
- Communication OPC-XML-Server
- SICAM PAS Configuration (Topology Management, Filtering, Topology Tree Structure, Selection of Signals for Each Sub-Level, Modbus (Measuring) Signals
- SICAM PAS Configuration (Automation (Soft PLC), Logic Processing with CFC, Info to / Com from SoftPLC (Mapping), Creating New CFC Program, Connection of Source and Destination Variables
- Routing messages from/to SoftPLC
- Renaming duplicated message
- Creating a CFC file
- CFC block
- Inserting Variable into interconnection column
- Grouping with a “PAS_GROUPI”-Function Block
- Converting a Counter Differential Value to a Counter Final Value
- Interlocking
- Run Sequence
- Online Mode
- Watchlist
- CDA (Control Data Analyzer) Necessary settings
- Mapping an output to CDA
- Human-Machine Control Center Mapping, Exporting of HMI1 Interface
- How to select a group of messages
- Normalization
- Create a Normalization Template
- Scaling a measured value
- Normalization as a multiple-used template
- Assignment of normalization in Mapping
- Adaptation of transformer tap position indications
- Archiving Configured Project, Un-archiving Project
SICAM PAS UI-Operation
- Updating the System
- Symbols in the tree view
- Operation – functions
- Exporting messages from PAS UI Configuration
SICAM PAS Value Viewer
- Mapping shows the Information Volume
- SICAM PAS Value Viewer
- The properties of a message
- Control function
- Testing data
- Important columns
- ValueViewer: Communication diagnostics
SICAM PQS
- Fault recording with SICAM PQS
- SICAM PQS – Functional Overview
- Incident Explorer
- PQ Explorer
- Grid Code Viewer
- Report Browser
- PQ Inspector
SCADA
- IEC 60870-5-101, the telecontrol profile
- IEC 60870 – 5 – 101 The most important features
- IEC 60870 – 5 – 101 telegram structure
- Type Identification in monitoring direction
- Type Identification in command direction
- Type Identification for organization objects
- Type Identification for parameters
- Quality Information
- IEC 60870-5-102, the counter profile
- IEC 60870-5-103, the IED/protection relay profile
- Creating an IEC103-Master and Interface
- Communication Parameters
- Data Units specified in IEC 60870-5-103
- Info Identification in PAS for IEC 60870-5-103
- IEC 60870-5-104, the network profile (based on 60870-5-101)
- Software IECTEST
- Settings for IEC 60870-5-104
- IEC 60870-5-104 Slave – Control Center Simulation
SICAM SCC
- Export of HMI information from SICAM PAS
- Check the content of a PXD file
- Introduction to SICAM PASCC Control Center
- SICAM PASCC Control Center ‐ Overview
- SIMATIC WinCC
- SICAM PASCC Components
- SICAM PASCC Communication
- SICAM PAS Wizard
- WinCC Explorer
- Graphic Objects Library
- Switchgear Objects
- Schwitchgear Objects – Styles and States
- Alarm Logging – Message List
- Control & Monitoring
- WinCC & PASCC Licensing
- SIMATIC WinCC / SICAM PASCC Installation Steps
- Transfer The License Keys
- SIMATIC WinCC / SICAM PASCC Time Synchronization & NTP
- SICAM PASCC Starting The WinCC/PASCC Software
- SICAM PASCC Creating/ Opening a New Project
- SICAM PASCC Defining The Computer Properties General Tab, Startup Tab, Parameters Tab, Graphics Runtime Tab
- Adding a Communication Driver
- Connection Properties
- Entering the IP Address of SICAM PAS Servers
- SICAM PAS Wizard Opening
- Error Log File of SICAM PAS Wizard
- Select a Right SICAM PAS Protocol Suite
- Set PAS IP Connection
- Importing of the Sample Pilot Project .pxd File
- Redefining the failed Sample Project
- Checking Structure Tags of a New Project
- Structure Tag Elements
- Symbol Library
- SICAM Administrative Internal Tags
- Schwitchgear Objects – Tag Connection
- Design of Graphical Objects
- Switchgear Objects – Sychro-Check
- Alarm Logging – Events & Alarms
- Alarm Logging – Message Queue & Mes Ack Tags
- Tag Logging – Measured Values
- WinCC Horn Tools– Sound File
- Tag Logging – Archive Configuration
- Trends Picture
- Topological coloring
- Event List
- Alarm List
- Protection Message List
- Horn, Alarm Acknowledgment
- Creating an Event List in the Graphics Designer
- How to scale analog values
- User Administrator
- Login-Function via key combination
- Login via button
- Defining level of rights
- Entering the requested right
- Displaying the current operator
- Report Designer – Print Job
- Project Archive, Duplicator
- Automatic Start of WinCC Project
- Recpro
- Setting Up SICAM PAS Recpro
- SICAM VALPRO
- SICAM VALPRO – Graphic functions
- Bay Blocking
Redundancy
- Redundancy Definition
- Dependency Definition
- Redundant Communication
- System Switchover
- Manual Switchover
- Redundant “Full Server – DIP” Configuration
- Configuring a Redundant System
- Transferring a database to a Redundant System
- Status indication in a redundant system
- Single Channel IEDs
- IED Redundancy
- System Redundancy
- Communication with Control Center
- Control Center with one interface
- Control Center with 2 Interfaces
- Communication via WAN Network
Example: Switching Authority in SICAM PAS
- Switching Authority Group
- Routing to PAS CC
- Switching Authority Tag
- SICAM PAS CC symbol library
- Configuring Button Switching Authority
- Test the Switching Authority
OPC Communication
- What is OPC ?
- OPC Applications
- Overview of OPC data flow
- OPC Server & Client
- Config OPC Server in the SICAM PAS UI-Configuration
- OPC Client
- OPC-XML-Server
- Difference between the OPC-XML-Server with the previous OPC
- Creating OPC XML Server in SICAM PAS
Additional Information
- Automation License Manager
- Tasks to be started with the Runtime
- Language and Key Disabling
- Graphics Runtime
- Data structure (monitoring/control direction)
Hardware Setup for SIEMENS SAS training
- SIPROTEC 5 Multifunction Relay IED
- Fiber optic to Ethernet converter
- Ethernet Switch
- PLC S7-1200
- PC (IEDScout, DIGSI4, DIGSI5, SICAM PAS, WinCC, TIA Portal, SICAM SCC, Wireshark, IEC61850 Configurator …)