Skip to main content
  • Online+ Pre-recorded Training
  • 3-5 April 2024
  • 22-24 March 2024
  • Pre-requisite training: DIGSI 4, DIGSI 5, IEC61850
  • Language: English
  • Supporting Files
  • Trainer: Dr. Saeed Roostaee (Profile)
  • Limited seats available
  • Registration link: End of this page

Module I: Substation Automation System

  • Substation Automation System-an overview
  • Introduction to Communication
  • Network Theory
  • Fundamentals of Communication Via Ethernet Various Topologies in SIEMENS SAS

Module II: Bay Level Engineering (IEC 61850 and Modbus)

  • Add SIPROTEC 4 6MD66 device
  • Setting the Network Parameters
  • 6MD configuration
  • IEC61850 Configuration
  • Updating ICD – Files

Module III: Station Level Engineering SICAM PAS

  • Introduction to SICAM PAS Automation System
  • SICAM PAS Tasks
  • Fields of Application
  • SICAM PAS Features
  • Scalability – Software and Hardware Configuration for Small to Large Applications
  • Basic Package “ Full Server”
  • SICAM PAS Packages (IEC 61850, Profibus FMS (SICAM/SIPROTEC specified protocols), IEC 60870-5-103, DNP V3.00, Profibus DP, Modbus, ILSA (Internal LSA protocol, OPC-Client, Automation CFC)
  • Licensing
  • Licensing With Feature Enabler
  • IEC 61850 Services in IEDs and SICAM PAS
  • SICAM PAS Configuration (Working with Project Databases, Creating a New Database, Adding and Managing Systems, Adding an Application (IEC 61850 Client), Importing a SCD file, Updating One or Several Device(s), Adding ModbusApplication, Parameterizing ModbusApplication, Added EMA90 ModbusMap, Defining the Device Template (ModbusMap), Adding IEC 60870-5-101 Slave Application, Inserting the Control Center of IEC 60870-5-101 Slave, Inserting the SNMP Application, Monitoring IEC 61850 IEDs Connection Status With SNMP, Inserting a PASCC Application to Full Server System, Inserting Control Center to PASCC Application, Inserting a PASCC to a New System (DIP)
  • Creating a CFC file
  • Human-Machine Control Center Mapping, Exporting of HMI1 Interface
  • Normalization
  • Create a Normalization Template
  • Scaling a measured value
  • Assignment of normalization in Mapping
  • Archiving Configured Project, Un-archiving Project
  • SICAM PAS Value Viewer
  • Control function
  • Testing data
  • ValueViewer: Communication diagnostics

Module IV: SICAM SCC

  • Export of HMI information from SICAM PAS
  • Check the content of a PXD file
  • Introduction to SICAM PASCC Control Center
  • SICAM PASCC Control Center ‐ Overview
  • SIMATIC WinCC
  • SICAM PASCC Components
  • SICAM PASCC Communication
  • SICAM PAS Wizard
  • WinCC Explorer
  • Graphic Objects Library
  • Switchgear Objects
  • Schwitchgear Objects – Styles and States
  • Alarm Logging – Message List
  • Control & Monitoring
  • WinCC & PASCC Licensing
  • SIMATIC WinCC / SICAM PASCC Installation Steps
  • Transfer The License Keys
  • SIMATIC WinCC / SICAM PASCC Time Synchronization & NTP
  • SICAM PASCC Starting The WinCC/PASCC Software
  • SICAM PASCC Creating/ Opening a New Project
  • SICAM PASCC Defining The Computer Properties General Tab, Startup Tab, Parameters Tab, Graphics Runtime Tab
  • Adding a Communication Driver
  • Connection Properties
  • Entering the IP Address of SICAM PAS Servers
  • Error Log File of SICAM PAS Wizard
  • Select the Right SICAM PAS Protocol Suite
  • Set PAS IP Connection
  • Importing of the Sample Pilot Project .pxd File
  • Checking Structure Tags of a New Project
  • Structure Tag Elements
  • Symbol Library
  • SICAM Administrative Internal Tags
  • Schwitchgear Objects – Tag Connection
  • Design of Graphical Objects
  • Switchgear Objects – Sychro-Check
  • Alarm Logging – Events & Alarms
  • Alarm Logging – Message Queue & Mes Ack Tags
  • Tag Logging – Measured Values
  • WinCC Horn Tools– Sound File
  • Tag Logging – Archive Configuration
  • Trends Picture
  • Topological coloring
  • Event List
  • Alarm List
  • Protection Message List
  • Horn, Alarm Acknowledgment
  • Creating an Event List in the Graphics Designer
  • User Administrator
  • Login via button
  • Report Designer – Print Job
  • Project Archive, Duplicator
  • Bay Blocking
  • Course Name: SIEMENS SAS
  • Pre-requisite training: DIGSI 4, DIGSI 5, IEC61850
  • Language: English
  • + Supporting Files
  • + Certificate of completion
  • Delivery: Face-to-face / Online
  • Duration: 8 Days
  • Trainer: Dr. Saeed Roostaee (Profile)

Substation Automation System

  • Substation Automation System-an overview
  • SIEMENS SAS In the past
  • SIEMENS SAS Nowadays
  • Network Theory (Types of Communications, Data Transmission Types, MAC Address, IP Address, Subnet Mask)
  • Fundamentals of Communication Via Ethernet Various Topologies
  • Ethernet and IEC 61850 Concepts (The EN100 Communication Module, Time Server, Switch, Network Card)
  • Important Factors for Choosing a Topology
  • Star Topology
  • Ring Topology

Hardware

  • RUGGEDCOM Ethernet Switch RS900
  • RUGGEDCOM Ethernet Switch RS8000
  • RUGGEDCOM Ethernet Switch RSG2100
  • SIPROTEC Communication Modules
  • Hirschmann Switches
  • Siemens Scalance – Switches
  • Modems
  • I/O-Box 6MD61
  • Bay Controller 6MD66
  • Transformer Regulators
  • SICAM 1703 device series – TM 1703 mic
  • SICAM 1703 device series – TM 1703 ACP
  • SICAM 1703 device series – BC 1703 ACP
  • SICAM 1703 device series – AK 1703 ACP
  • Siemens Serial Modem 7XV5655
  • Siemens converter – Mini star coupler
  • Com-Expander: Comtrol Rocket Port
  • Operator Desk / Engineering PCs
  • Time receiver
  • external time masters
  • NTP-time synchronization with SICLOCK
  • Modem Splitter
  • Station Unit 6MD9101
  • SICAM PAS Station Unit

Bay Level Engineering (IEC 61850 and Modbus)

  • Sample IEC 81850 Configuration
  • Setting the Network Parameters for Ethernet Switches
  • Modbus Connection of Measuring Centers
  • Serial/Ethernet Converter (7XV5655)
  • GPS Satellite Clock
  • IEC 61850 – The Configuration Language SCL File Types at a glance
  • ICD file – IED Capability Description
  • SSD file – Substation Specification Description
  • CID file – Configured IED Description
  • SCD file – Substation Configuration Description
  • IEC 61850 Services in IEDs and SICAM PAS
  • Updating ICD – Files
  • IEC 61850 – creating PAS configuration data
  • Client/Server Communication
  • Publisher / Subscriber Communication
  • Logical Node
  • Data Objects
  • Standardizing Communication with Logical Nodes
  • Addressing control of a circuit breaker
  • Ethernet switches according to IEC61850 specification
  • Ethernet Master clocks
  • IEC61850 Engineering
  • Process of IEC61850 Engineering
  • Diagnosis Tool Networkview
  • Diagnosis Tool IEC-Browser
  • Config signals in the DIGSI 4 Matrix
  • Config signals in the DIGSI 5 IEC61850 structure
  • System Configurator in DIGSI
  • Assign IEDs to the IEC 61850 Station
  • Mapping GOOSE messages
  • Updating device parameter files
  • IEC 61850 Ethernet Medium: FO Ring
  • IEC 61850 Ethernet Configuration: Electrical Star
  • IEC 61850 Ethernet FO-Ring with RuggedCom
  • IEC 61850 Ethernet FO-Ring with optical EN100
  • IEC 61850 Ethernet – Partial Redundant FO-Ring
  • IEC 61850 Ethernet – Redundant FO-Ring
  • IEC 61850 Ethernet – with redundant PAS
  • Sample Real Projects
  • Export of Station Information
  • Import of SCD-File into the SICAM PAS

Station Level Engineering SICAM PAS

  • Introduction to SICAM PAS Automation System
  • SICAM PAS Tasks
  • Fields of Application
  • SICAM PAS Features
  • Scalability – Software and Hardware Configuration for Small to Large Applications
  • Basic Package “ Full Server”
  • Distributed system with higher performance (Full Server + DIP (Device Interface Processor))
  • High availability by Redundancy
  • High flexibility through further interfaces
  • Optional Packages (IEC 61850, Profibus FMS (SICAM/SIPROTEC specified protocols), IEC 60870-5-103, DNP V3.00, Profibus DP, Modbus, ILSA (Internal LSA protocol, OPC-Client, Automation CFC)
  • Substation Automation Functions (Control Authority, Bay Blocking, Telecontrol Blocking, Time Synchronization, Fault Recording, Redundancy)
  • SICAM PAS in Star Configuration
  • SICAM PAS in (Fiber Optic) Ring
  • SICAM PAS FO Station LAN
  • SICAM PAS Installation
  • Licensing
  • Licensing With Feature Enabler
  • SICAM PAS Basic packet and options
  • SICAM PAS Configuration User Administration Tool
  • IEC 61850 Services in IEDs and SICAM PAS
  • SICAM PAS Configuration (Working with Project Databases, Creating a New Database, Adding and Managing Systems, Adding an Application (IEC 61850 Client), Importing a SCD file, Updating One or Several Device(s), Adding ModbusApplication, Parameterizing ModbusApplication, Added EMA90 ModbusMap, Defining the Device Template (ModbusMap), Adding IEC 60870-5-101 Slave Application, Inserting the Control Center of IEC 60870-5-101 Slave, Inserting the SNMP Application, Monitoring IEC 61850 IEDs Connection Status With SNMP, Inserting a PASCC Application to Full Server System, Inserting Control Center to PASCC Application, Inserting a PASCC to a New System (DIP)
  • Creating a Full Server Computer
  • Creating an IEC101-Master to connect the RTU
  • Importing the RTU file
  • Communication IEC 60870-5-103
  • Communication OPC-Client (based on COM/DCOM)
  • Communication OPC-XML-Server
  • SICAM PAS Configuration (Topology Management, Filtering, Topology Tree Structure, Selection of Signals for Each Sub-Level, Modbus (Measuring) Signals
  • SICAM PAS Configuration (Automation (Soft PLC), Logic Processing with CFC, Info to / Com from SoftPLC (Mapping), Creating New CFC Program, Connection of Source and Destination Variables
  • Routing messages from/to SoftPLC
  • Renaming duplicated message
  • Creating a CFC file
  • CFC block
  • Inserting Variable into interconnection column
  • Grouping with a “PAS_GROUPI”-Function Block
  • Converting a Counter Differential Value to a Counter Final Value
  • Interlocking
  • Run Sequence
  • Online Mode
  • Watchlist
  • CDA (Control Data Analyzer) Necessary settings
  • Mapping an output to CDA
  • Human-Machine Control Center Mapping, Exporting of HMI1 Interface
  • How to select a group of messages
  • Normalization
  • Create a Normalization Template
  • Scaling a measured value
  • Normalization as a multiple-used template
  • Assignment of normalization in Mapping
  • Adaptation of transformer tap position indications
  • Archiving Configured Project, Un-archiving Project

SICAM PAS UI-Operation

  • Updating the System
  • Symbols in the tree view
  • Operation – functions
  • Exporting messages from PAS UI Configuration

SICAM PAS Value Viewer

  • Mapping shows the Information Volume
  • SICAM PAS Value Viewer
  • The properties of a message
  • Control function
  • Testing data
  • Important columns
  • ValueViewer: Communication diagnostics

SICAM PQS

  • Fault recording with SICAM PQS
  • SICAM PQS – Functional Overview
  • Incident Explorer
  • PQ Explorer
  • Grid Code Viewer
  • Report Browser
  • PQ Inspector

SCADA

  • IEC 60870-5-101, the telecontrol profile
  • IEC 60870 – 5 – 101 The most important features
  • IEC 60870 – 5 – 101 telegram structure
  • Type Identification in monitoring direction
  • Type Identification in command direction
  • Type Identification for organization objects
  • Type Identification for parameters
  • Quality Information
  • IEC 60870-5-102, the counter profile
  • IEC 60870-5-103, the IED/protection relay profile
  • Creating an IEC103-Master and Interface
  • Communication Parameters
  • Data Units specified in IEC 60870-5-103
  • Info Identification in PAS for IEC 60870-5-103
  • IEC 60870-5-104, the network profile (based on 60870-5-101)
  • Software IECTEST
  • Settings for IEC 60870-5-104
  • IEC 60870-5-104 Slave – Control Center Simulation

SICAM SCC

  • Export of HMI information from SICAM PAS
  • Check the content of a PXD file
  • Introduction to SICAM PASCC Control Center
  • SICAM PASCC Control Center ‐ Overview
  • SIMATIC WinCC
  • SICAM PASCC Components
  • SICAM PASCC Communication
  • SICAM PAS Wizard
  • WinCC Explorer
  • Graphic Objects Library
  • Switchgear Objects
  • Schwitchgear Objects – Styles and States
  • Alarm Logging – Message List
  • Control & Monitoring
  • WinCC & PASCC Licensing
  • SIMATIC WinCC / SICAM PASCC Installation Steps
  • Transfer The License Keys
  • SIMATIC WinCC / SICAM PASCC Time Synchronization & NTP
  • SICAM PASCC Starting The WinCC/PASCC Software
  • SICAM PASCC Creating/ Opening a New Project
  • SICAM PASCC Defining The Computer Properties General Tab, Startup Tab, Parameters Tab, Graphics Runtime Tab
  • Adding a Communication Driver
  • Connection Properties
  • Entering the IP Address of SICAM PAS Servers
  • SICAM PAS Wizard Opening
  • Error Log File of SICAM PAS Wizard
  • Select a Right SICAM PAS Protocol Suite
  • Set PAS IP Connection
  • Importing of the Sample Pilot Project .pxd File
  • Redefining the failed Sample Project
  • Checking Structure Tags of a New Project
  • Structure Tag Elements
  • Symbol Library
  • SICAM Administrative Internal Tags
  • Schwitchgear Objects – Tag Connection
  • Design of Graphical Objects
  • Switchgear Objects – Sychro-Check
  • Alarm Logging – Events & Alarms
  • Alarm Logging – Message Queue & Mes Ack Tags
  • Tag Logging – Measured Values
  • WinCC Horn Tools– Sound File
  • Tag Logging – Archive Configuration
  • Trends Picture
  • Topological coloring
  • Event List
  • Alarm List
  • Protection Message List
  • Horn, Alarm Acknowledgment
  • Creating an Event List in the Graphics Designer
  • How to scale analog values
  • User Administrator
  • Login-Function via key combination
  • Login via button
  • Defining level of rights
  • Entering the requested right
  • Displaying the current operator
  • Report Designer – Print Job
  • Project Archive, Duplicator
  • Automatic Start of WinCC Project
  • Recpro
  • Setting Up SICAM PAS Recpro
  • SICAM VALPRO
  • SICAM VALPRO – Graphic functions
  • Bay Blocking

Redundancy

  • Redundancy Definition
  • Dependency Definition
  • Redundant Communication
  • System Switchover
  • Manual Switchover
  • Redundant “Full Server – DIP” Configuration
  • Configuring a Redundant System
  • Transferring a database to a Redundant System
  • Status indication in a redundant system
  • Single Channel IEDs
  • IED Redundancy
  • System Redundancy
  • Communication with Control Center
  • Control Center with one interface
  • Control Center with 2 Interfaces
  • Communication via WAN Network

Example: Switching Authority in SICAM PAS

  • Switching Authority Group
  • Routing to PAS CC
  • Switching Authority Tag
  • SICAM PAS CC symbol library
  • Configuring Button Switching Authority
  • Test the Switching Authority

OPC Communication

  • What is OPC ?
  • OPC Applications
  • Overview of OPC data flow
  • OPC Server & Client
  • Config OPC Server in the SICAM PAS UI-Configuration
  • OPC Client
  • OPC-XML-Server
  • Difference between the OPC-XML-Server with the previous OPC
  • Creating OPC XML Server in SICAM PAS

Additional Information

  • Automation License Manager
  • Tasks to be started with the Runtime
  • Language and Key Disabling
  • Graphics Runtime
  • Data structure (monitoring/control direction)

Hardware Setup for SIEMENS SAS training

  • SIPROTEC 5 Multifunction Relay IED
  • Fiber optic to Ethernet converter
  • Ethernet Switch
  • PLC S7-1200
  • PC (IEDScout, DIGSI4, DIGSI5, SICAM PAS, WinCC, TIA Portal, SICAM SCC, Wireshark, IEC61850 Configurator …)

In this course, you will learn how to use and configure the IEC 61850 station

IEC 61850 Configuration Video Training

  • IEC 61850 Configuration
  • Language: English
  • Course creation: December 2018
  • Last update: September 2023
  • Total Time till September 2023: 5 hrs
  • + Auxiliary Files
  • + Certificate of completion
  • Trainer: Dr. Saeed Roostaee (Profile)

Main Course

  • Part 1 Substation Automation – An overview.
  • Part 2 An introduction to IEC 61850 & how to learn it effectively.
  • Part 3 Overview of the main features of IEC 61850.
  • Part 4 Overview of the main features of IEC 61850 – Part II
  • Part 5 IEC 61850 data structure and data format – Part I
  • Part 6 IEC 61850 data structure and data format – Part II
  • Part 7 IEC 61850 station in DIGSI 5 and IEC 61850 System Configurator.
  • Part 8 GOOSE configuration and the publisher-subscriber LNs.
  • Part 9 GOOSE simulation via IEDScout.
  • Part 10 GOOSE configuration and simulation between SIP 5 & SEL relays.
  • Part 11 Time synchronization settings and SNTP configuration.
  • Part 12 Case Study – Part I
  • Part 13 Case study – Part II
  • Part 14 Case study – Part III
  • Part 15 IEC 61850 configuration in DIGSI 4
  • Part 16 IEC 61850 configuration between SIP 4 & SIP 5.
  • Part 17 Sample project.

Updates and Supplementary Files

  • IEC 61850 configuration in PCM600 (Process bus and Goose configuration).
  • IEC 61850 Engineering with PCM600.
  • How to configure IEC 61850 with Easergy Studio
  • How to configure IEC 61850 for the ACE850 module (CET850).
  • How to configure IEC 61850 for SEL relays.

Helpful Files:

IEC protocols for substation communications

IEC 61850 Technical Overview

Download the IEC 61850 training package

Details Course

Part 1: Substation Automation- Overview

substation protection and control systems development, from conventional to digital substations with some pictures of a real substation. Then, it presents the importance of communication in this system and why it is necessary to use a common communication protocol and molding function system in the substation automation system.    

Part 2: An introduction to IEC 61850 & how to learn it effectively

A brief history of the standard IEC 61850 Ed.1 & Ed.2, its purpose, and its benefits are presented in this chapter. One problem with learning the IEC 61850 is the variety of documents, topics, and the gap between academics and industry in this area. This part introduces an effective way to learn practical IEC 61850 standards.

Part 3: Overview of the main features of IEC 61850-Part I

This part overviews the OSI model, MMS protocol, and the used devices in the IEC 61850 network. Then, different packets (GOOSE, Report, and Sample Value) and services (for time synchronization, master-slave, client/server, and publisher/subscriber) are presented in this module.

Part 4: Overview of the main features of IEC 61850-Part II

The concept of object-oriented modeling and the data modeling of IEC 61850 are presented in this part. Then different types of GOOSE messages, report control blocks, and SCL files are introduced. This part also presents the connection terminals, communication, and time synchronization ports of a merging unit installed in the process bus lab setup.

Part 5: IEC 61850 data structure and data format-Part I

Initial IEC 61850 settings in DIGSI 5 and the connection between the information routing matrix and IEC 61850 structure editor are presented in this part. The device is opened via OMICRON IEDScout and the data structure of the IED and the relation between them and the IEC 61850 signals in DIGSI 5 are explained. Then the device is exported with different IEC 61850 data formats and different sections of the exported files are explained in detail. To understand the interoperability of IEC 61850, a device from another manufacturer (SEL) is also exported and different sections of this file are explained.

Part 6: IEC 61850 data structure and data format-Part II

Different tools of the IEC 61850 structure editor in DIGSI 5. Editing of the IEC 61850 data model and adding the user-defined LNs are explained too.

Part 7: IEC 61850 station in DIGSI 5 and IEC 61850 System Configurator

A device is added to the IEC station in DIGSI 5 and the station is opened via IEC 61850 System Configurator to explain different parts of the station and the configurator. The connection between each editor in the configurator and the station file is also presented in this part.

Part 8: GOOSE configuration and the publisher/subscriber LNs

The GOOSE configuration between two SIPROTEC 5 devices is presented in this part. The publisher and the subscriber Logical Nodes before the GOOSE configuration and after the GOOSE configuration are compared in the IEC 61850 station files and the information matrix in DIGSI 5.

Part 9: GOOSE simulation via IEDScout

The publisher and subscriber IEDs before and after GOOSE configuration are simulated in the OMICRON IEDScout. The sniffer tool is used to capture the simulated GOOSE of the publisher IED. To show the GOOSE repetition, the value of the GOOSE signal is changed in the IED simulator, and the captured GOOSE after the change is analyzed too.

Part 10: GOOSE configuration and simulation between SIP 5 & SEL relays

An IED from another manufacturer (SEL) is added to the station and the GOOSE configuration between SEL and SIPROTEC IEDs is presented in the IEC 61850 configurator. Then the simulation of the publisher and subscriber IEDs has been done via IEDScout.

Part 11: Time synchronization settings and SNTP configuration

The configuration of the SNTP (Simple Network time protocol) for time synchronization in DIGSI 5 and IEC 61850 system configurator

Part 12: Case study-Part I

In DIGSI 5 training, relays were added and configured based on the diagram of the case study project. This part presents the IEC 61850 configuration in the same case study project. The IEC 61850 and SNTP settings have been entered based on the case study project documents. The table of the communication cables and the diagram of the substation automation architecture is described in this part.

Part 13: Case study-Part II

The report configurations based on the table of reports configured on servers are presented in this part. The signals of the distance IED are added to the data set and a report control block is added to transmit the event to the clients. The report control block settings are also explained in this part.

Part 14: Case study-Part III

The GOOSE configurations are based on the GOOSEs table and the GOOSE message subscription list.

Part 15: IEC 61850 configuration in DIGSI 4

  • the IEC 61850 configuration in DIGSI 4
  • The data model of a SIPROTEC 4 IED is shown in the OMICRON IEDScout
  • the IEC 61850 signals in the masking IO with this data model

Part 16: IEC 61850 configuration between SIP 4 & SIP 5

  • The IEC 61850 station configuration with SIPROTEC 4 and SIPROTEC 5 devices

Part 17: Sample project

  • The application of GOOSE signals, a sample project
  • The IEDs and IEC 61850 configurations (send a GOOSE signal from SIPROTEC 5 to SIPROTEC 4)
  • Use the GOOSE signal in a function block of the DIGSI 4 CFC editor

IEC 61850 configuration in PCM600 (Process bus and Goose configuration)
IEC 61850 Engineering with PCM600
How to configure IEC 61850 with Easergy Studio
How to configure IEC 61850 for ACE850 module (CET850)
How to configure IEC 61850 for SEL relays

Click here to see the certificates of the participants

IEC 61850 System Configurator Video Training

Auxiliary files:

Related training packages:

Topics:

Substation Automation System:

  • Substation Automation- Overview
  • SAS Introduction
  • SAS history
  • SAS future
  • Substation Automation Functions
  • Process level
  • Bay level
  • Station Level

Network & Ethernet:

  • Ethernet Concepts
  • Fundamentals of Communication Via Ethernet
  • Network Theory
  • Components of the Network
  • Fundamentals of Communication Via Ethernet Various Topologies
  • Important Factors for Choosing a Topology
  • Required Redundancy
  • Distances Between Devices and Physical Dimensions of a Network
  • Price Consideration
  • Simple (Pure) Star
  • Star Topology with Double Take
  • Ring and Star Combination
  • Economical Ring Solution With Only one External Switch
  • Ring Topology With Two External Switches
  • Commonly Used Configurations
  • One Ring and Several Stars (most Frequently Occurring Topology)
  • Two Rings Fitted into Each other
  • Two Rings Connected Via a Double Main Ring
  • Introduction: Provide an overview of SICAM PAS system
  • Install SICAM PAS software and System components
  • The new project, PAS Operation and Configure an IEC 103 interface
  • How to use Device Descriptions (files)
  • How to use the SICAM Value Viewer
  • Configure an IEC 101 interface and T101 slave interfaces
  • Configure an IEC 104 interface, T104 interface
  • Introduction to IEC61850
  • Creating a DIGIS database for a siprotec relay
  • IEC61850 system configurator
  • Data export and import
  • Configure an IEC 61850 interface
  • Normalization, Normalizing measured values
  • Configure a PAS CC interface, Configuring an HMI interface
  • Connect an IEC 61850 IED

IEC 61850:

  • IEC 61850 Concepts
  • An Introduction to IEC 61850
  • IEC 61850 data structure and data format
  • Information Modeling
  • Interoperability
  • Architecture: Station & Process Buses
  • Logical Nodes
  • ACSI – Class Models
  • DataSet
  • Communication models
  • Controls
  • GOOSE / GSSE
  • Client / Server
  • Data Reporting & Logging
  • Sampled Values
  • Time Synch
  • GOOSE & Ethernet Frames
  • 7-OSI Layers & Client / Server
  • MMS Protocol
  • ASN.1 Encoding & Message Parsing
  • SCL Syntax and Semantics
  • .ICD/.CID Files: IED definitions
  • .SCD File: Substation Section
  • Access Points & Communications
  • EC 61850 station in DIGSI 5 and IEC 61850 System Configurator
  • Time synchronization settings and SNTP configuration
  • IEC 61850 configuration in DIGSI 4
  • GOOSE configuration and the publisher/subscriber LNs
  • GOOSE simulation via IEDScout
  • Sample IEC61850 Configuration & Parameterization of a SIPROTEC 4 Device (BCU)

SIEMENS SAS

  • Introduction to SICAM PAS Automation System
  • Fields of Application
  • Hardware Configuration
  • Setting the Interface Parameters
  • Setting for Time Synchronization
  • Configuration of IEC 61850 Network
  • Inter Bay Communication GOOSE
  • Modbus Connection of Measuring Centers (EMA90)
  • RS484 Bus Connection
  • EMA90 Connection Setting
  • Setting the Network Parameters for Ethernet Switches
  • Configuration of General Parameters of Ethernet Switches
  • Configuration of RSTP Bridge & RSTP Port Parameters
  • Configuration of SNMP Users, Group, and Access
  • 7XV6555 Serial/Ethernet Converter
  • 7XV5655 Configuration Tool
  • 7XV5655 Parameterization
  • GPS Satellite Clock
  • Server Type of Satellite Clock
  • PCI Card type of Satellite Clock
  • Station Level Engineering
  • SICAM PAS Installation System Types
  • Demo Version
  • Licensed Version
  • Installation Requirements
  • SICAM PAS Configuration Working with Project Databases
  • SICAM PAS UI-Operation
  • SICAM PAS Value Viewer
  • SICAM PASCC
  • Introduction to SICAM PASCC Control Center
  • Overview of SICAM PAS CC
  • SICAM PASCC
  • Starting The WinCC/PASCC Software

Practical Section

working with SIPROTEC 5 multifunction relay IED 7SX800

Substation Automation System Training
Substation automation System Training digsi 4 config
Substation Automation System Training 6md bay controller
Substation Automation System Training sicam pass

IP communication is being extensively introduced into the operation of the Electrical Power Utility. The substation IP network environment has evolved from acting as an extension of the office LAN to a state, where it is carrying multiple services, including the transport of critical and sensitive data.
IP communication, being a one-platform solution that relieves you from designing and maintaining more than one
network, is not a one-technology solution. Therefore, the implementation of an IP network needs to be carefully planned to achieve the expected scalability and performance.
This Technical Brochure includes the following:

  • A compilation of user requirements and expectations concerning existing and envisaged services in the new
  • networked environment of the substation.
  • A description of possible network migration processes
  • Guidelines on how to choose an optimum network architecture
  • A description of important parameters to be considered for each relevant technology.
  • Six case studies describing project and process experiences

Communication Architecture for IP-Based Substation Applications Download

  • Trainer: Dr. Saeed Roostaee (Profile)

This course is an overview of the application, properties, and functional scope of the 6MD bay controller. Also, the configuration and parameters of the 6MD IED are presented in this training.

6MD bay controller
SIPROTEC 6MD bay controller

20 WhatsApp Groups for protection engineers to join:

  • WhatsApp Grp 01: Protection Relay – General
  • WhatsApp Grp 02: Substation Automation – General
  • WhatsApp Grp 03: Transmission line protection
  • WhatsApp Grp 04: Transformer protection
  • WhatsApp Grp 05: Motor protection
  • WhatsApp Grp 06: Generator protection
  • WhatsApp Grp 07: Overcurrent and Earth Fault Protection
  • WhatsApp Grp 08: Busbar protection and Bay controller
  • WhatsApp Grp 09: Breaker protection and control
  • WhatsApp Grp 10: Protection Relay Testing and commissioning
  • WhatsApp Grp 11: DIgSILENT
  • WhatsApp Grp 12: ETAP
  • WhatsApp Grp 13: PSCAD
  • WhatsApp Grp 14: IEC 61850 configuration
  • WhatsApp Grp 15: Switchgear GIS & AIS
  • WhatsApp Grp 16: GE Relay Configuration
  • WhatsApp Grp 17: SIEMENS Relay configuration
  • WhatsApp Grp 18: Schnider Relay configuration
  • WhatsApp Grp 19: SEL Relay Configuration
  • WhatsApp Grp 20: ABB Relion configuration

Click here to join these groups

Please send the group’s numbers which you are interested in on WhatsApp. number : +989129613659

7

contact us to get this impressive IEC61850 collection

  • IEC 61850 Precision Time Protocol IEEE 1588
  • IEC 61850 PRP Redundancy
  • IEC 61850 Quality of Service
  • IEC 61850 Redundancy Protocols
  • IEC 61850 Substation Architecture
  • IEC 61850 Substation Design Considerations
  • IEC 61850 Time Synchronization
  • IEEE 1588 – Master, Slave, and Transparent Clocks
  • IEEE 1588 Synchronization Basics
  • Important Properties of PTP
  • Integrating Serial and IP Ethernet
  • Introduction to IEEE 1588 Precision Time Protocol
  • Network Management System Deployment Scenarios
  • Network Management System Security
  • Network Security- The Defense in Depth Model
  • NMS User Guide- Device Discovery
  • NMS User Guide- Permissions and Users
  • NMS User Guide- Statistics
  • NMS User Guide- Views and Alarms
  • Product Overview – RAPTOREye
  • PTP Profiles
  • PTP Timing Requirements in Power Systems
  • Securing a Switch and Functional Architecture
  • Security Standards and the NERC CIP Framework
  • Serial IP Conversion Use Case
  • Switch Hardening_ Local Password and Access Authentication
  • Switch Hardening- Finalizing the Security Configuration
  • Switch Hardening- Secure Management and Configuration
  • The Best Master Clock Algorithm
  • The Gap Between Legacy Serial and Ethernet
  • The Network Management System FCAPS Model
  • Time Transfer Technology Comparison
  • Virtual Serial Port Redirection
  • What is a Network Management System (NMS)
  • Name Size Date Modified
  • Best Practice – Securing SNMP
  • Best Practice_ Securing Management Protocols
  • Best Practice- Enabling Remote Logging
  • Best Practice- Time Sync, Disable Services, and Port Security
  • Converting Serial to IP
  • Core Redundancy and OSPF
  • Defense in Depth Model
  • Device Hardening- Best Practice Basics
  • Device Level Security and Switch Functional Architecture
  • Digital Substations- An Introduction to IEC 61850
  • Ethernet Network Overview
  • Gateway Redundancy – VRRP
  • How does a VLAN work
  • How PTP IEEE 1588 v2 Works
  • HSR-PRP Redundancy
  • IEC 61850 Communication Protocols
  • IEC 61850 HSR Redundancy
  • Interior Routing Protocol
  • Layer 2 and Redundancy
  • Layer 3 Concepts – Routing
  • MAC and IP Addressing Format
  • Managed vs Unmanaged Switch and Router
  • Migration from Serial to Ethernet
  • Redundancy Architecture from Substation to Control Center
  • Redundant Network Timing Requirements
  • Routing Functions and The Routing Table
  • Static Routing vs. Dynamic Routing
  • STP and RSTP Redundancy
  • The Physical Layer
  • VLAN Basics
  • VLANs (IEEE 802.1Q)
  • VLANs and Redundancy
  • VLANs, Routing, and Cybersecurity
  • What Is a Switch
  • What is a VLAN
  • What is Ethernet
  • Bridging the Gap Ethernet, Serial, and Legacy Equipment in Substations
  • Digital Substation Communications – What you Need to Know About IEC61850 Network Design
  • Educational Training Introduction_ Networking 101 For OT Professionals
  • IEC61850 Overview Video
  • It’s about Time – Intro to IEEE 1588 and Precision Time Protocol
  • Keeping an Eye Out_ Understanding Network Management Utilization
  • Network Hardening, NERC CIP and the Smart Grid
  • Network Redundancy- What Are Your Options- Why Choose One Technology over Another
  • Networking 101 for OT Professionals_ Ethernet and its Application in Critical Utility Networks
  • Networking 101 For OT Professionals- Making Sense of the Layers. Benefits of Layer 2 and Layer 3
  • Switch Hardening Best Practices- How to Secure Your Industrial Network
  • VLAN Fundamentals and Its Benefit in Network Design for Mission Critical Applications
  • Name Size Date Modified
  • Alex Apostolov about the past, present and the future of relay protection
  • Christoph Brunner about origins of IEC 61850 and its future developments — Big Energy.
  • IoT for Utility and Industrial Power Grids- Where Is the value-
  • Route to IEC 61850 (2016)- The Concept of IEC 61850
  • Route to IEC 61850- Engineering IEC 61850 systems
  • Route to IEC 61850- HMI and Station Control
  • Route to IEC 61850- Testing IEC 61850 Systems
  • Route to IEC 61850- The Concept of IEC 61850
  • Route to IEC 61850- Time Synchronization for IEC 61850
  • The Future of Industrial Automation Video – GE Intelligent Platforms
  • Welcome to the Digital Substation World I Episode 01
  • ABB Goose config
  • Cara Create ICD_SCD File (IEC61850 Protocol) dari Relay Reyrolle Argus 7SR
  • Fiber Optic and Data Transferring between Substations and OTDR
  • GE course
  • GE DCS
  • GE Geese confgi procedure
  • Hands on Protection Testing using IEC 61850
  • How to configure IEC 61850 with Easergy Studio
  • How to enable Virtual Machine on Latest Windows Host Operating System
  • How to generate the IEC 61850 MMS GOOSE Protocol traffic using SCL files with IEDScout
  • How to perform the compare and find difference between the SCL files
  • How to save the SCL file from IEDScout
  • How to setup OpenSCD to be used in offline
  • How to subscribe the GOOSE messages from third-party relays to ABB make relays in PCM600
  • How to use IEDScout in offline and the benefits behind
  • How to use IEDScout in offline to practic
  • IEC 61850 implementation-related documentation for IEDs and Tools
  • IEC 61850 Overview Part 9 SCL Files
  • IEC 61850 programming training
  • iec61850.
  • ied scout
  • Introduction and contents overview
  • Introduction to packet sniffing and basics of communication protocols
  • Making right connections to start sniffing in switched environment
  • Start capturing with Wireshark and manage its basic settings
  • Using Filters
  • Working with packets
  • Working with capture files
  • Digital substation traffic capture analysis
  • Practical demonstration
  • IEDScout on MBX1 IEC 61850 IED Simulation with Positive use cases
  • ieee1588
  • OMICRON Customer Portal Overview
  • Route to IEC 61850 (2016)- The Concept of IEC 61850
  • SEL Goose config
  • SETR850 schnider
  • Simulating an IED from IEDScout PC with 102 port-occupied services
  • StationScout offline benefits-Part-1
  • STRATON IEC61850
  • Trick Rahasia Edit CID File IEC61850 untuk Integrasi SIPROTEC5 PACIS Alstom
  • Using IEC 61850 to Solve Protective Relaying Challenges (2011).mp4 292 M
  • ABB webinar
  • Awareness of IEC 61850 communication standard – Preface and tutors introduction
  • digsi 4 iec61850 config
  • digsi4 report
  • easergy pro
  • ethernet
  • How does Modbus Communication Protocol Work
  • IEC 61850 Data Modeling Part 2 – Triangle MicroWorks Inc
  • IEC 61850 in the Modern Substation
  • IEC 61850 Standard for T&D Grids
  • iec 61850 webinar omicron
  • IEC 61850
  • IEC_61850_Simply_usable_mit_closing.
  • iot – 38 – Lecture 3.3 Packet Capture Demo
  • Mensajes GOOSE en IEC61850 de Siemens
  • omicron goose
  • omicron products
  • omicron SV
  • Relational Database Concepts
  • sip5 iec61850
  • triangle
  • Practical IEC 61850 for Substation Automation for Engineers and Technicians
  • Video Session 2- Practical IEC 61850 for Substation Automation for Engineers and Technicians
  • Video Session 3- Practical IEC 61850 for Substation Automation for Engine
  • What is OSI Model
  • What is the IEC 61850 protocol- How does it work- What’s the difference with other protocols
  • SIPROTEC 5 certificate automation – using Enrollment over Secure Transport protocol
  • Webinar SIPROTEC 5 certificate Secure Transport EST protocol
  • Expert Talk – Overview of SICAM A8000, SIAPP & Web HMI
  • Global Summit 2022 Digital switchgears for intelligent secondary distribution grid automation
  • Global Summit 2022 Behind the scenes– Self optimized grid to the largest onshore fish farm in Norway
  • Global Summit 2022 Conference Digital switchgear solutions for primary distribution
  • Global Summit 2022 Conference Precisely tailored substation automation with SICAM A8000
  • Global Summit 2022 Keynote Innovative technologies in electrification & automation for our future
  • Global Summit 2022 Mastering distribution grid diversification by IoT SIPROTEC5
  • Global Summit 2022 SICAM A8000 beyond the typical substation automation–New apps for the Etransition
  • Global Summit 2022 Training How to write your own application for SICAM A8000 with SIAPP
  • Migration of SICAM TOOLBOX II configuration
  • SICAM Earth Fault Indicator – SICAM EFI Introduction Animation (FR)
  • SICAM Earth Fault Indicator – SICAM EFI Introduction Animation
  • Automation and remote terminal units SICAM A8000 RTU SIPROTEC-5 SIEMENS
  • Sicam Application CP8050 Automation and remote terminal units A8000 RTU SIPROTE