Power System Protection Training

  • Curse Code: #PSP1
  • Course Name: Power System Protection
  • Delivery: Online (Google Meet/ MS Meet) or Face-to-face
  • Duration: 5 days
  • Instructor: Dr. Saeed Roostaee

Day 1

Basic overview of Generation and transmission

  • Electrical grid
  • National Grid
  • Power System components
  • Single Line Diagram (SLD)
  • Power Generation Technologies
  • Hydro-Electric Power
  • Fossil fuel power
  • Nuclear power generation
  • Wind energy
  • Diesel Engine
  • Solar power

Components of Substation

  • Overhead lines
  • Potential transformer
  • Disconnect switch
  • Circuit breaker
  • Current transformer
  • Lightning arrester
  • Main transformer
  • Control Panel
  • Mettering Panel
  • Protection Panel
  • TCS Relay
  • Trip Relay
  • Lockout Relay

Type of Busbar Configurations

  • Single Bus-Bar Arrangement
  • Single Bus-Bar Arrangement with Bus Sectionalized
  • Main and Transfer Bus Arrangement
  • Double Bus Double Breaker Arrangement
  • Double Bus Single Breaker Arrangement
  • One and a Half Breaker Arrangement

Protection Classification, Types & ANSI Codes

  • Common Acronyms
  • ANSI Standard Device Numbers
  • 21 Distance Relay
  • 21G Ground Distance
  • 21P Phase Distance
  • 24 Volts-per-Hertz Relay / Overfluxing
  • 25 Synchronizing or Synchronism-Check Device
  • 27 Undervoltage Relay
  • 27P Phase Undervoltage
  • 32R Reverse Power
  • 46 Reverse-Phase or Phase Balance Current Relay or Stator Current Unbalance
  • 49 Machine or Transformer Thermal Relay / Thermal Overload
  • 50 Instantaneous Overcurrent Relay
  • 50BF Breaker Failure
  • 50N Neutral Instantaneous Overcurrent
  • 51 Time Overcurrent Relay
  • 51N Neutral Time Overcurrent
  • 51V Voltage-Relained Time Overcurrent
  • 59 Overvoltage Relay
  • 67 Directional Overcurrent Relay
  • 67N Neutral Directional Overcurrent
  • 79 Ac Reclosing Relay / Auto Reclose
  • 81 Frequency Relay
  • 81O Over Frequency
  • 81U Under Frequency
  • 86 Locking-Out Relay
  • 87 Differential Protective Relay
  • 87B Bus Differential
  • 87G Generator Differential
  • 87GT Generator/Transformer Differential
  • 87L Line Current Differential
  • 87M Motor Differential
  • 87RGF Restricted Ground Fault
  • 87T Transformer Differential

Protection Single Line Diagram

  • PSLD
  • Line Protection
  • Feeder Protection
  • Generator Protection
  • Transformer Bay

Day 2

Numerical Protection Relays

  • Protection Technology from Siemens
  • SIPROTEC RELAY FAMILIES
  • Hardware structure of the SIEMENS numerical multi-functional device
  • SIPROTEC 4 relay block diagram
  • SIPROTEC 5
  • Properties of SIPROTEC 5
  • SIPROTEC 5 expansion modules
  • Modular device concept, freely configurable
  • Devices without Jumpers- no more opening of the device
  • Sampling rate up to 16 kHz
  • Draw out of the terminal blocks
  • On-Site operation panel
  • ABB Relion Protection Relays
  • ABB Relay hardware

START WITH DIGSI 5

  • DIGSI 5 installation
  • SIPROTEC drivers
  • Manage device drivers
  • Upgrade DIGSI 5 Version
  • DIGSI 5 User interface
  • Start with DIGSI 5
  • DIGSI 5 function library
  • Function Point
  • Embedding of Functions in the Device

Working Online with the SIPROTEC 5 (Practical Section)

  • Assign an online device to the project
  • Copy the online device to the project
  • Change Device mode
  • SIPROTEC 5 Web browser
  • Set date and time
  • Monitor binary inputs, outputs, and LEDs
  • Change parameters in the relays
  • Relay binary inputs/outputs test

Relay Measurements (Practical Section)

  • Inject the three-phase values into the relay and monitor the relay measurements
  • Operational Measured Values
  • Fundamental Components
  • Symmetrical Components
  • Monitor relay phasor values

Relay Logs and Events (Practical Section)

  • Reading Indications from the PC
  • Operational Log
  • Fault Log
  • Ground-Fault Log

Relay Fault Recorder (Practical Section)

  • Fault Recording
  • Fault recorder settings
  • Fault recorder config
  • Download fault records
  • Comtrade File

Overcurrent and Earth fault

  • Overcurrent DT 50
  • Overcurrent IT 51
  • Overcurrent curves
  • How to configure OC protection
  • How to test OC protection
  • IE calculation
  • IE measurements
  • Config earth fault protection
  • How to test EF protection

Directional Overcurrent and Earth fault

  • Why Directional overcurrent protection
  • How to configure Directional overcurrent protection (ANSI67)
  • Simulate a fault in the forward direction
  • Simulate a fault in the backward direction
  • How to Test Direction OC Protection
  • Directional overcurrent fault logs and records
  • How does 67N work?
  • Config Directional Earth Fault overcurrent (ANSI67N)
  • Fault simulation to test 67N
  • Test 67N with simulated signals
  • Fault logs with 67N operation
  • Fault record with 67N operation

Day 3

Transformer Protection

  • Why Transformer Protection
  • Earth Fault on H.V. External Connections
  • Phase-to-Phase Fault on H.V. External Connections, Internal Earth Fault on H.V. Windings
  • Internal Phase-to-Phase Fault on H.V. Windings Short Circuit Between Turns H.V. Windings
  • Earth Fault on L.V. External Connections
  • Phase-to-Phase Fault on L.V. External Connections, Internal Earth Fault on L.V. Windings
  • Internal Phase-to-Phase Fault on L.V. Windings Short Circuit Between Turns L.V. Windings
  • Transformer Protection Scheme
  • SIPROTEC 7UT8 config
  • Application templates
  • Two-winding transformers
  • Three-winding transformer basic (87T)
  • Three-winding transformer 1.5CB
  • Function Group Differential
  • Function Group Side

Day 4

Line Protection

  • Transmission Line Faults
  • Line protection functions
  • Why Use Distance Protection?
  • How Distance protection works
  • Distance Protection
  • Distance measurement (principle)
  • phase- phase -loop
  • phase- ground -loop
  • Load and short-circuit impedances
  • Distance characteristics
  • Stepped Distance protection
  • SIPROTEC 7SA8 Configuration
  • SIPROTEC 7SA8 Application templates
  • BI Config: Under Voltage blocking
  • BI Config: PUTT receive signal
  • BI Config: Channel PUTT faulty
  • BI Config: DEF receive
  • BI Config: DEF channel faulty
  • BI Config: DS position for release STUB (DS Open)
  • BI Config: CVT MCB Fail
  • BI Config: CB Position
  • User-defined: SUB II Faulty
  • BO Config: 1/3 pole Trip
  • BO Config: Close Cmd
  • BO Config: 85-21 PUTT send
  • BO Config: 85-21 DEF send
  • Distance Protection in SIPROTEC 7SA8
  • Pickup method
  • Distance zones (quadrilateral characteristic curve preconfigured)
  • Ground-fault detection
  • Direction Determination

Day 5

Generator Protection

  • Generator Introduction
  • Synchronous Generator
  • Generator construction
  • Stator
  • Rotor
  • Salient pole rotor
  • Cylindrical rotor
  • Synchronous Generator Operation
  • Equivalent circuit of a synchronous generator
  • Generator connection
  • Direct Connected Generators
  • Unit Connected Generator
  • Faults in Generators
  • Stator Earth Faults
  • Rotor Earth Faults
  • Stator Short Circuits
  • Stator Interturn faults
  • External faults
  • Stator Winding Faults
  • Control System and Field Winding/Rotor Circuit Faults
  • Abnormal Operating Conditions
  • 32 Reverse Power
  • 40 Loss of Excitation
  • 46 Negative Sequence
  • 49 Thermal Overload
  • 51V voltage restraint
  • 51G Ground over current
  • 64 Ground Relay
  • 87 Differential
  • Generator Stator Earth Fault Protection
  • 87GD Generator Ground Differential
  • 59N overvoltage protection
  • 95 % of the stator winding protection
Online Relay testing training using Our lab