GE Multilin Feeder Protection: 350 and 850 Relays – Overcurrent Protection, Directional Elements, Autoreclosing, Breaker Failure and Commissioning

Table Of Contents
  1. 1. Introduction
  2. 2. GE Multilin 350 and 850 Feeder Protection Relays
  3. 3. Feeder Protection Philosophy
  4. 4. Feeder Overcurrent Protection (ANSI 50/51)
  5. 5. Earth-Fault Protection (ANSI 50N/51N and 50G/51G)
  6. 6. Directional Overcurrent Protection (ANSI 67)
  7. 7. Feeder Protection Coordination
  8. 8. Autoreclosing Protection (ANSI 79)
  9. 9. Breaker Failure Protection (ANSI 50BF)
  10. 10. Voltage and Frequency Protection
  11. 11. CT and VT Configuration for Feeder Protection
  12. 12. Practical Feeder Protection Example
  13. 13. GE Multilin 350 and 850 Configuration Workflow
  14. 14. Testing GE Multilin Feeder Protection Relays
  15. 15. Common Feeder Protection Problems
  16. 16. Feeder Protection Commissioning Checklist
  17. 17. Engineering Recommendations
  18. 18. Conclusion
  19. 19. Training on GE Multilin Feeder Protection by Elec-Engg

1. Introduction

Feeder protection is one of the most common applications of numerical protection relays in electrical distribution and industrial power systems.

Feeders connect substations, transformers, busbars, motors, industrial loads, and distribution networks. Their protection systems must detect short circuits, earth faults, overloads, abnormal voltage conditions, and other electrical disturbances while maintaining selectivity with upstream and downstream protection devices.

GE Multilin provides feeder protection solutions that include the 350 Feeder Protection System and the 850 Feeder Protection System. These relays are designed for feeder protection applications, with available functions depending on the exact product version, firmware, hardware, and configuration.

This article explains the practical engineering of GE Multilin feeder protection, including phase overcurrent, earth-fault protection, directional overcurrent, voltage protection, autoreclosing, breaker failure, CT and VT configuration, protection coordination, EnerVista engineering, and commissioning.

2. GE Multilin 350 and 850 Feeder Protection Relays

2.1 GE Multilin 350

The GE Multilin 350 is a feeder protection relay intended for distribution and industrial feeder applications.

Depending on its configuration, it may provide functions such as:

  • Phase overcurrent protection.
  • Ground-fault protection.
  • Directional overcurrent protection, where supported.
  • Voltage protection, where supported.
  • Breaker failure protection, where supported.
  • Autoreclosing, where supported.
  • Measurement and monitoring.
  • Programmable logic.
  • Communication functions.

2.2 GE Multilin 850

The GE Multilin 850 is a feeder protection system designed for more advanced feeder protection and control applications.

Depending on the exact configuration, its application may include:

  • Phase overcurrent protection.
  • Earth-fault protection.
  • Directional protection.
  • Voltage and frequency protection.
  • Autoreclosing.
  • Breaker failure protection.
  • Monitoring and disturbance recording.
  • Programmable logic and control.
  • Substation communication and integration.

2.3 Comparing the 350 and 850

Engineering consideration350850
Feeder protectionYes, application-dependentYes, application-dependent
Phase overcurrentVerify exact versionVerify exact version
Earth-fault protectionVerify exact versionVerify exact version
Directional protectionVerify exact versionVerify exact version
AutoreclosingVerify exact versionVerify exact version
Breaker failureVerify exact versionVerify exact version
CommunicationModel-dependentModel-dependent
Advanced control and monitoringConfiguration-dependentConfiguration-dependent

This table is an application overview, not a guaranteed feature matrix. Always check the ordering code, firmware, and product manual before engineering or purchasing a relay.

3. Feeder Protection Philosophy

A feeder protection scheme should detect faults within the protected circuit and isolate the faulty section without unnecessarily disconnecting healthy parts of the network.

Typical feeder protection functions include:

Protection functionANSI number
Instantaneous phase overcurrent50
Time phase overcurrent51
Instantaneous earth-fault overcurrent50N/50G
Time earth-fault overcurrent51N/51G
Directional phase overcurrent67
Directional earth-fault overcurrent67N
Undervoltage27
Overvoltage59
Underfrequency81U
Overfrequency81O
Autoreclosing79
Breaker failure50BF
Synchrocheck25
Thermal overload49
Negative-sequence protection46

The actual protection functions depend on the feeder type, network grounding, relay capabilities, and protection study.

4. Feeder Overcurrent Protection (ANSI 50/51)

Overcurrent protection detects current exceeding a configured threshold.

It is widely used for radial distribution feeders and as backup protection in more complex networks.

4.1 Instantaneous Overcurrent (50)

Instantaneous overcurrent protection operates when the measured current exceeds a configured pickup value.

It is commonly used for high-current faults close to the feeder source.

The pickup must be selected to:

  • Detect relevant high-current faults.
  • Avoid operation during maximum load.
  • Remain stable during motor starting and transformer energization where applicable.
  • Coordinate with downstream protection.

4.2 Time Overcurrent (51)

Time overcurrent protection provides delayed fault clearing.

The operating time depends on the measured current and the selected time-current characteristic.

Common curve types include:

  • Definite time.
  • Standard inverse.
  • Very inverse.
  • Extremely inverse.
  • Other manufacturer-specific characteristics.

4.3 IEC Inverse-Time Characteristic

A commonly used IEC standard inverse characteristic is:

[
t=\frac{0.14\times TMS}{(I/I_s)^{0.02}-1}
]

Where:

  • (t) is operating time in seconds.
  • (TMS) is the time multiplier setting.
  • (I) is measured current.
  • (I_s) is the pickup current.

The equation is provided as a standard inverse example. Always select the actual curve equation corresponding to the relay’s configured characteristic.

5. Earth-Fault Protection (ANSI 50N/51N and 50G/51G)

Earth faults can occur when a phase conductor contacts grounded equipment, cable screens, metallic structures, or earth.

The magnitude of earth-fault current depends on the system grounding arrangement.

5.1 Residual Earth-Fault Measurement

Residual current can be calculated from the three phase currents:

[
I_{\text{res}}=I_A+I_B+I_C
]

During balanced operation, the vector sum is approximately zero.

An earth fault can produce a residual current that is detected by the relay.

5.2 Core-Balance CT

A core-balance CT measures the residual current of all phase conductors passing through its window.

It can provide sensitive earth-fault detection, particularly where the expected fault current is relatively low.

The engineer must verify the CT installation, conductor arrangement, cable screen grounding, and relay input compatibility.

5.3 Grounding System Considerations

Earth-fault protection must be coordinated with the system grounding method:

  • Solidly grounded.
  • Resistance grounded.
  • Reactance grounded.
  • Isolated or ungrounded.

The pickup and time delay should be based on the calculated earth-fault current and the required coordination with upstream and downstream devices.

6. Directional Overcurrent Protection (ANSI 67)

Directional overcurrent protection is required when fault current can flow in more than one direction.

Examples include:

  • Ring networks.
  • Parallel feeders.
  • Networks with multiple sources.
  • Embedded generation.
  • Interconnected distribution systems.

A conventional non-directional overcurrent element responds mainly to current magnitude and time.

A directional element also determines whether the fault is in the configured forward or reverse direction.

6.1 Operating Quantities

Directional overcurrent protection uses current and a polarizing voltage or another supported reference quantity.

The relay evaluates the phase relationship between the operating and polarizing quantities.

6.2 Forward and Reverse Direction

The engineer must define the forward direction based on the feeder’s protection reference.

Incorrect CT polarity, VT phase assignment, or directional reference configuration can cause incorrect directional decisions.

6.3 Directional Earth-Fault Protection (67N)

Directional earth-fault protection uses suitable residual current and polarizing quantities.

Depending on the network grounding arrangement, the relay may use residual voltage, neutral voltage, or another supported directional method.

The actual method and settings must be checked against the relay documentation.

7. Feeder Protection Coordination

Coordination ensures that the protection device closest to the fault operates first, while upstream protection provides backup.

For a radial feeder, a typical protection hierarchy may include:

  1. Downstream fuse or protection relay.
  2. Feeder relay.
  3. Transformer incomer relay.
  4. Upstream substation protection.

7.1 Coordination Time Interval

A coordination time interval (CTI) provides a time margin between primary and backup protection.

The required interval depends on:

  • Relay operating times.
  • Circuit-breaker opening times.
  • Overtravel or reset characteristics where relevant.
  • Measurement and setting tolerances.
  • Protection scheme design.

There is no single CTI value that is suitable for every system.

7.2 Time-Current Curves

The engineer should plot the upstream and downstream protection characteristics on a common current basis.

The comparison should include:

  • Minimum and maximum fault current.
  • Maximum load current.
  • Cable damage curves.
  • Transformer damage curves.
  • Motor starting current, where applicable.
  • Fuse characteristics.
  • Circuit-breaker clearing time.

8. Autoreclosing Protection (ANSI 79)

Autoreclosing is widely used on overhead distribution and transmission feeders where a significant proportion of faults may be temporary.

Examples include:

  • Lightning-related flashover.
  • Temporary conductor contact.
  • Wind-blown vegetation.
  • Transient insulation flashover.
  • Temporary contamination-related faults.

After the protection relay trips the circuit breaker, the autoreclosing function may issue a reclosing command after a configured dead time.

8.1 Reclosing Sequence

A simplified autoreclosing sequence is:

  1. Feeder fault occurs.
  2. Protection relay detects the fault.
  3. Circuit breaker trips.
  4. Dead time starts.
  5. Autoreclosing function issues a close command.
  6. The relay monitors whether the fault has cleared.
  7. If the fault persists, protection trips again according to the configured sequence.

8.2 Single-Shot and Multi-Shot Reclosing

A scheme may use one or more reclosing attempts.

The number of shots and the dead times depend on the network design and utility operating philosophy.

8.3 Reclosing Blocking

Autoreclosing should be blocked for fault conditions where reclosing is not permitted.

Examples may include:

  • Transformer internal faults.
  • Busbar faults.
  • Cable faults.
  • Certain breaker failure conditions.
  • Manual trip conditions.
  • Other non-reclose conditions defined by the protection philosophy.

The exact blocking logic must be documented and tested.

9. Breaker Failure Protection (ANSI 50BF)

Breaker failure protection operates when a circuit breaker fails to interrupt current after receiving a trip command.

A breaker failure condition can cause severe damage and may require upstream isolation.

9.1 Operating Principle

A typical breaker failure scheme includes:

  • Trip initiation.
  • Breaker current supervision.
  • Breaker auxiliary contact supervision.
  • Timer.
  • Retrip logic.
  • Backup trip output.

If current continues to flow after the expected breaker opening time, the breaker failure logic may operate.

9.2 Breaker Failure Setting Considerations

The timer should consider:

  • Breaker operating time.
  • Relay output time.
  • Current supervision.
  • Circuit-breaker auxiliary contact response.
  • Required safety margin.
  • Upstream breaker clearing time.

9.3 Breaker Failure Tripping

The backup trip action may involve:

  • Upstream circuit breaker.
  • Bus coupler breaker.
  • Adjacent feeder breakers.
  • Remote-end tripping, where applicable.

The final trip arrangement must follow the approved protection design.

10. Voltage and Frequency Protection

Feeder protection may include voltage and frequency elements depending on the application.

10.1 Undervoltage Protection (27)

Undervoltage protection detects voltage below a configured threshold.

Applications may include:

  • Motor feeder protection.
  • Load shedding.
  • Supply abnormality detection.
  • Network restoration schemes.

10.2 Overvoltage Protection (59)

Overvoltage protection detects excessive voltage.

It may be used where the feeder protection design requires voltage supervision or protection against abnormal supply conditions.

10.3 Frequency Protection (81)

Underfrequency and overfrequency protection may be used for load shedding, distributed generation disconnection, or other system protection functions.

Settings must be coordinated with utility grid-code requirements and plant operating philosophy.

11. CT and VT Configuration for Feeder Protection

Correct CT and VT configuration is essential for dependable feeder protection.

11.1 CT Configuration

The engineer must verify:

  • CT ratio.
  • CT secondary rating.
  • CT polarity.
  • Phase assignment.
  • Accuracy class.
  • Secondary burden.
  • Protection input compatibility.

11.2 VT Configuration

Where voltage-dependent protection is used, verify:

  • VT ratio.
  • Phase-to-phase or phase-to-neutral connection.
  • Phase sequence.
  • Polarity.
  • Fuse or MCB arrangement.
  • Voltage input scaling.

11.3 Residual Voltage

Residual voltage may be required for directional earth-fault protection or other supervision functions.

The measurement arrangement may use three-phase VT connections or a broken-delta arrangement, depending on the scheme.

The actual relay input requirements must be confirmed before wiring.

12. Practical Feeder Protection Example

Consider an 11 kV radial feeder with:

  • Maximum normal load current: 180 A.
  • CT ratio: 300/1 A.
  • Calculated maximum three-phase fault current: 5 kA.
  • Downstream protection: another numerical relay.

The secondary current at maximum load is:

[
I_{\text{load,sec}}=\frac{180}{300}=0.6\text{ A}
]

The secondary current at the calculated fault current is:

[
I_{\text{fault,sec}}=\frac{5000}{300}=16.67\text{ A}
]

These values help the engineer assess measurement scaling and the available current range.

They do not, by themselves, determine the final overcurrent pickup or time settings.

The final settings must consider:

  • Maximum emergency load.
  • Minimum fault current.
  • Downstream coordination.
  • CT performance.
  • Cable and equipment limits.
  • Breaker interrupting capability.

13. GE Multilin 350 and 850 Configuration Workflow

The exact configuration procedure depends on the relay model, firmware, and supported engineering software.

A general workflow is:

Step 1 – Review the Feeder Design

Collect:

  • Single-line diagram.
  • CT and VT drawings.
  • Feeder cable data.
  • Maximum load current.
  • Minimum and maximum fault levels.
  • System grounding arrangement.
  • Circuit-breaker data.
  • Coordination study.

Step 2 – Identify the Relay

Confirm:

  • Relay model.
  • Ordering code.
  • Firmware version.
  • Current input rating.
  • Voltage input configuration.
  • Binary input and output modules.
  • Communication options.

Step 3 – Configure CT and VT Ratios

Enter the installed CT and VT ratios.

Verify the current and voltage measurements using known values.

Step 4 – Configure Overcurrent Protection

Configure the required phase and earth-fault elements.

Review pickup, curve type, time multiplier, and instantaneous settings.

Step 5 – Configure Directional Elements

Where supported and required, configure:

  • Forward direction.
  • Reverse direction.
  • Polarizing quantities.
  • Characteristic angle.
  • Directional supervision.
  • Operating logic.

Step 6 – Configure Autoreclosing

Where available, configure:

  • Number of shots.
  • Dead times.
  • Reclaim time.
  • Reclose conditions.
  • Blocking signals.
  • Manual close supervision.

Step 7 – Configure Breaker Failure

Where supported, configure current supervision, timer, retrip, and backup trip logic.

Step 8 – Configure Inputs and Outputs

Map protection elements to the correct alarm, trip, and control outputs.

Verify the breaker trip and close circuits.

Step 9 – Save and Review

Save the settings and compare them against the approved coordination study and protection drawings.

14. Testing GE Multilin Feeder Protection Relays

Testing should verify individual protection elements and the complete feeder control and trip arrangement.

14.1 CT Measurement Test

Inject known current values and verify:

  • Phase current magnitude.
  • CT scaling.
  • Phase assignment.
  • Current polarity.
  • Residual current.

14.2 Overcurrent Test

Test instantaneous and time overcurrent elements.

Verify:

  • Pickup current.
  • Operating time.
  • Curve characteristic.
  • Reset behavior.
  • Trip output.

14.3 Earth-Fault Test

Inject the appropriate residual or core-balance current.

Verify pickup, timing, and trip logic.

14.4 Directional Test

Apply suitable voltage and current signals representing forward and reverse fault conditions.

Verify directional decisions and the associated overcurrent operation.

14.5 Autoreclosing Test

Simulate a trip and verify the dead time, close command, reclaim time, shot counter, and blocking conditions.

Do not perform live breaker reclosing tests unless the approved commissioning procedure and operational permissions allow them.

14.6 Breaker Failure Test

Simulate a trip command while maintaining the breaker failure supervision conditions.

Verify the timer, retrip, and backup trip outputs.

14.7 Voltage and Frequency Test

Where applicable, inject the required voltage and frequency conditions and verify pickup and operating time.

14.8 Trip Circuit Test

Verify the complete circuit:

Protection element → Relay logic → Output contact → Lockout or trip relay → Circuit breaker trip coil

For autoreclosing, also verify the breaker close circuit and associated interlocks.

15. Common Feeder Protection Problems

Problem 1 – Feeder Trips During Normal Load

Possible causes:

  • Incorrect CT ratio.
  • Incorrect pickup setting.
  • Incorrect phase assignment.
  • Excessive actual load.
  • Incorrect thermal or overload configuration.

Recommended action: Verify measured current and compare it with the approved load and protection study.

Problem 2 – Feeder Does Not Trip for an Expected Fault

Possible causes:

  • Pickup too high.
  • Incorrect CT scaling.
  • Incorrect trip output mapping.
  • Directional element blocking.
  • Defective trip circuit.
  • Incorrect protection logic.

Recommended action: Check relay measurements, element status, event records, and trip circuit continuity.

Problem 3 – Directional Protection Operates in the Wrong Direction

Possible causes:

  • Incorrect CT polarity.
  • Incorrect VT phase sequence.
  • Incorrect polarizing voltage.
  • Incorrect directional reference.
  • Incorrect characteristic angle.

Recommended action: Verify CT and VT wiring and perform controlled forward/reverse directional testing.

Problem 4 – Autoreclosing Does Not Operate

Possible causes:

  • Reclosing disabled.
  • Blocking input active.
  • Incorrect shot counter state.
  • Breaker not ready.
  • Missing close circuit permissive.
  • Incorrect trip initiation logic.

Recommended action: Review autoreclosing status, blocking conditions, and breaker control inputs.

Problem 5 – Breaker Failure Protection Operates Unnecessarily

Possible causes:

  • Incorrect timer.
  • Incorrect current supervision.
  • Incorrect breaker auxiliary contact.
  • Incorrect retrip logic.
  • Incorrect trip initiation.

Recommended action: Verify breaker opening time and the complete breaker failure logic.

16. Feeder Protection Commissioning Checklist

  • Approved single-line diagram reviewed.
  • Relay model and firmware confirmed.
  • CT ratios and polarity verified.
  • VT ratios and phase sequence verified.
  • Current and voltage measurements checked.
  • Phase overcurrent tested.
  • Earth-fault protection tested.
  • Directional protection tested, where applicable.
  • Voltage and frequency protection tested, where applicable.
  • Autoreclosing sequence tested, where applicable.
  • Reclosing blocking conditions verified.
  • Breaker failure logic tested, where applicable.
  • Trip and close outputs verified.
  • Circuit-breaker auxiliary contacts checked.
  • Communication and monitoring checked.
  • Event records and disturbance records reviewed.
  • Final settings and test reports archived.

17. Engineering Recommendations

For dependable GE Multilin feeder protection:

  1. Use an accurate feeder single-line diagram.
  2. Calculate maximum and minimum fault currents.
  3. Verify CT and VT ratios and polarities.
  4. Coordinate phase and earth-fault protection with downstream devices.
  5. Consider motor starting and transformer energization where applicable.
  6. Use directional protection when the network permits reverse fault-current flow.
  7. Define autoreclosing conditions and blocking signals carefully.
  8. Coordinate breaker failure protection with upstream isolation.
  9. Test forward and reverse directional operation.
  10. Verify the complete breaker trip and close circuits.
  11. Review relay event records after commissioning.
  12. Maintain controlled settings files and revision records.

18. Conclusion

GE Multilin 350 and 850 feeder protection relays are used in feeder protection applications with capabilities that depend on the exact product version and configuration.

A reliable feeder protection scheme requires correct application of phase overcurrent, earth-fault protection, directional elements, voltage and frequency protection, autoreclosing, and breaker failure functions where required.

The most important engineering tasks are correct CT and VT configuration, accurate fault calculations, protection coordination, suitable logic configuration, and comprehensive commissioning tests.

The protection engineer should always verify the selected relay’s actual capabilities and settings against the manufacturer’s documentation and the approved protection design.

19. Training on GE Multilin Feeder Protection by Elec-Engg

Elec-Engg provides practical technical training by Dr Saeed Roostaee (Electrical Engineering) for engineers involved in feeder protection, distribution networks, substation protection, relay engineering, testing, and commissioning.

Relevant training topics include:

  • GE Multilin 350 and 850 feeder protection.
  • Phase overcurrent protection (ANSI 50/51).
  • Earth-fault protection (50N/51N and 50G/51G).
  • Directional overcurrent protection (67/67N).
  • CT and VT configuration.
  • Protection coordination and time-current curves.
  • Autoreclosing protection (79).
  • Breaker failure protection (50BF).
  • Voltage and frequency protection.
  • EnerVista settings management.
  • Secondary injection testing.
  • Practical commissioning and troubleshooting.

Training is available through pre-recorded video courses, structured self-paced programs, live online sessions, face-to-face courses, and customized in-house training.

Visit https://elec-engg.com/ to explore available technical training programs or contact Elec-Engg through https://elec-engg.com/contact/ for customized training requirements.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top