- Trainer: Dr. Saeed Roostaee (Profile)
- Pre-recorded videos with online access+Free updates +Free certification +Free technical support
Content:
Supplementary Files: The important related files/ videos /software and attached to the course as extra files.
Any queries, please feel free to contact me at: saeed61850@gmail.com
Part A: Introduction, general settings, Hardware & connection, Impedance/Vector/report View, the test object, …
- A 01 (Length: 02 min, Update: Oct 3, 2021): Introduction
- A 02 (Length: 05 min, Update: Oct 3, 2021): Strat page (Omicron)
- A 03 (Length: 06 min, Update: Oct 3, 2021): General settings (Omicron)
- A 04 (Length: 05 min, Update: Oct 3, 2021): Strat page (Vebko)
- A 05 (Length: 14 min, Update: Oct 3, 2021): Phasor view, Impedance view (Omicron)
- A 06 (Length: 06 min, Update: Oct 3, 2021): Phasor view, Impedance view, differential view (Vebko)
- A 07 (Length: 04 min, Update: Oct 3, 2021): Hardware connection
- A 08 (Length: 10 min, Update: Oct 3, 2021): Practical section with Omicron 256 plus, SEL 421
Part B: Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)
- B 01 (Length: 19 min, Update: Oct 3, 2021): Test object, Overcurrent RIO block, testing of overcurrent
- B 02 (Length: 16 min, Update: Oct 3, 2021): Settings of the Overcurrent test module
- B 03 (Length: 15 min, Update: Oct 3, 2021): Practical section
- B 04 (Length: 17 min, Update: Oct 3, 2021): Practical section
- B 05 (Length: 06 min, Update: Oct 3, 2021): Practical section
- B 06 (Length: 15 min, Update: Oct 3, 2021): Practical section
- B 07 (Length: 09 min, Update: Oct 3, 2021): Practical section
- B 08 (Length: 15 min, Update: Oct 3, 2021): Practical section
- B 09 (Length: 22 min, Update: Oct 3, 2021): Practical section
- B 10 (Length: 23 min, Update: Oct 3, 2021): Practical section (directional overcurrent concepts, settings, practice)
- B 11 (Length: 06 min, Update: Oct 3, 2021): Practical section (directional overcurrent testing)
Part C: Differential Protection Functions (87G, 87T, 87L)
- C 01 (Length: 03 min, Update: Oct 27, 2021): Diff protection principal
- C 02 (Length: 11 min, Update: Oct 27, 2021): Diff parameters
- C 03 (Length: 12 min, Update: Oct 27, 2021): Diff RIO block
- C 04 (Length: 05 min, Update: Oct 27, 2021): Diff configuration
- C 05 (Length: 07 min, Update: Oct 27, 2021): Diff Operating Characteristic
- C 06 (Length: 12 min, Update: Oct 27, 2021): Diff Trip Time Characteristic & Diff Harmonic Restraint
Part D: XRIO and PTL
- D 01 (Length: 13 min, Update: Nov 13, 2021): RIO and XRIO history and why we should use this format for relay testing, RIO structure, XRIO structure, Differences between RIO and XRIO files, XRIO features & benefits, LinkToXRIO
- D 02 (Length: 05 min, Update: Nov 13, 2021): XRIO template, How to Import Relay Settings, How to find a proper XRIO template and filter based on the relay
- D 03 (Length: 08 min, Update: Nov 13, 2021): Common problems while loading the relay settings into a template and how to solve the issues, XRIO template based on the relay versions
- D 04 (Length: 06 min, Update: Nov 13, 2021): Explain a case study XRIO file
- D 05 (Length: 10 min, Update: Nov 13, 2021): Modify a case study XRIO file
- D 06 (Length: 09 min, Update: Nov 13, 2021): Modify the XRIO template, RIO blocks
Part E: Impedance Protection Functions
- E 01 (Length: 09 min, Update: Nov 26, 2021): Distance RIO block
- E 02 (Length: 07 min, Update: Nov 26, 2021): Advance Distance Test Module settings
- E 03 (Length: 08 min, Update: Nov 26, 2021): Distance protection function principal, Impedance View
- E 04 (Length: 18 min, Update: Nov 26, 2021): Analysis of several faults visually in the impedance view
- E 05 (Length: 19 min, Update: Nov 26, 2021): Analysis of several distance relays (RAZOA, ABB REL670, SEL421, Siemens 7SA8x, MiCOM P442, NR PCS 931S, Protecta)
- E 06 (Length: 08 min, Update: Nov 26, 2021): Distance Test Module settings
- E 07 (Length: 12 min, Update: Nov 26, 2021): Preparing XRIO file for testing of impedance protection functions
Part F: Autoreclosure Function (ANSI 79)
- F 01 (Length: 04 min, Update: Dec 03, 2021): Autoreclosure Description, auto reclose process
- F 02 (Length: 05 min, Update: Dec 03, 2021): Autoreclosure settings, Autoreclose timing diagram
- F 03 (Length: 11 min, Update: Dec 03, 2021): Autoreclosure simulation
- F 04 (Length: 12 min, Update: Dec 03, 2021): Testing of AR in state sequencer
- F 05 (Length: 09 min, Update: Dec 03, 2021): Testing of AR in the Autorecoser test module
Part G: Voltage and Frequency Protection Functions (ANSI 27, ANS59, ANSI81O, 81U)
- G 01 (Length: 06 min, Update: Dec 08, 2021): Ramping test modules and testing the frequency functions
- G 02 (Length: 05 min, Update: Dec 08, 2021): Paulse ramping test module
- G 03 (Length: 06 min, Update: Dec 08, 2021): Continous ramp and step ramp
- G 04 (Length: 11 min, Update: Dec 08, 2021): How to test Over/Under voltage protection functions (59, 27)
Part H: Study functions, testing, and commission of SIPROTEC 7UT6
- H 01 (Length: 10 min, Update: Dec 20, 2021): SIPROTEC 7UT6 setting description and configuration
- H 02 (Length: 14 min, Update: Dec 20, 2021): How to test differential function in SIPROTEC 7UT6, No combined characteristic feature, Automate testing by creating SIEMENS 7UT XRIO file
- H 03 (Length: 18 min, Update: Jan 01, 2022): The procedure of testing transformer protection with Quick CMC
Part K: Study functions, testing, and commission of MiCOM P44x
- K 01 (Length: 19 min, Update: Oct 31, 2022): Hardware and function description of the MiCOM P441, P442 & P444
- K 02 (Length: 17 min, Update: Oct 31, 2022): MiCOM Relay connections, communication, and Wire connection test
- K 03 (Length: 05 min, Update: Nov 1, 2022): Distance protection parameters and testing
- K 04 (Length: 10 min, Update: Nov 1, 2022): Switch on to fault protection (SOTF) function parameters and testing
- …
- Introduction, Software Installation, and general settings
- Different types of test modules
- Impedance/Vector/report View, Display settings
- Test Object, Hardware Configuration
- RIO, XRIO, and PTL
- Control Center, How to create and modify XRIO/ PTL files
- Transient module, Advanced transplay
- RIO Function Over Current, Define Element Characteristic, Pick-Up/ Drop-Off Test
- Testing of the Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)
- Distance Configuration, Settings, Shot Test, Check Test, Search Test, Z\t Diagram, Zone Settings
- Testing of the Distance function (21)
- Principle of Differential Protection, Operating Characteristic, Differential Configuration, Differential Operating Characteristic, Differential Trip Time, and Harmonic Restraint
- Testing of the Differential protection function (87, 87G, 87T)
- Testing of the Power swing function
- Autoreclosure, shot and times, unsuccessful / Successful Sequence
- Testing of the Autorecloser function
- Testing of the Fault location function
- Testing of the Over/Under frequency (81O/ 81U)
- Testing of the Over/Undervoltage (59, 27)
- Testing of the Pole-Slip function (78)
- Testing of the Loss of Excitation (40)
- Testing of the Negative Phase Sequence (46)
- Testing of the Overload (49)
- How to test the distance function if the distance module is deactivated in the test universe software
- How to test differential function if the differential module is deactivated in the test universe
- Practical sections with testing of the relays (ABB REG670, MiCOM P441, MiCOM P123, …)
The testing & commissioning of the protection relays can be done by different testing software and hardware. In this training, we have used OMICRON Test Universe, Vebko AMpro, and FREJA win.