SIPROTEC 5 Protection Relays: Models, Applications & DIGSI 5 Training

Discover the Siemens SIPROTEC 5 protection relay family, including 7SJ82, 7SJ85, 7SA86, 7SD87, 7SL87, 7UT85, 7UT87, 7SK85, 7SS85, 7UM85, 7VE85, 7SX85 and more. Learn about their applications in power generation, transmission, distribution and industrial power systems, and explore professional SIPROTEC 5 and DIGSI 5 training courses.

Table Of Contents
  1. 1. Introduction to Siemens SIPROTEC 5 Protection Relays
  2. 2. Main Features and Advantages of SIPROTEC 5
  3. 3. SIPROTEC 5 Relay Models and Their Applications
  4. 4. SIPROTEC 5 Relay Selection Guide
  5. 5. SIPROTEC 5 and DIGSI 5 Engineering: What Should Protection Engineers Learn?
  6. 6. SIPROTEC 5 Relay Testing and Commissioning Training
  7. 7. Advanced SIPROTEC 5 and DIGSI 5 Training by Elec-Engg
  8. 8. Why Choose Elec-Engg for SIPROTEC 5 Training?
  9. 9. Contact Us for SIPROTEC 5 and Relay Testing Training
  10. Frequently Asked Questions (FAQ)

1. Introduction to Siemens SIPROTEC 5 Protection Relays

Modern electrical power systems require reliable, selective and intelligent protection solutions to ensure the safety of electrical equipment, personnel and power supply continuity.

The Siemens SIPROTEC 5 protection relay family represents a comprehensive platform for digital protection, control, automation, monitoring and power quality applications.

Designed for modern substations, power plants, transmission networks, distribution systems and industrial installations, SIPROTEC 5 provides advanced protection functions combined with flexible hardware, configurable software and powerful communication capabilities.

Unlike conventional protection relays, SIPROTEC 5 devices offer modular hardware and software configurations. This allows protection engineers to select the required functions, communication interfaces, binary inputs and outputs, and hardware modules according to the specific application.

The SIPROTEC 5 family covers a wide range of applications, including:

  • Overcurrent and feeder protection
  • Distance protection
  • Line differential protection
  • Combined line differential and distance protection
  • Transformer differential protection
  • Motor protection
  • Generator protection
  • Busbar protection
  • Circuit-breaker management
  • Bay control and substation automation
  • High-speed busbar transfer
  • Generator synchronization and paralleling
  • Fault recording and power quality monitoring
  • Merging unit and process bus applications

SIPROTEC 5 is particularly important for engineers involved in protection system design, relay configuration, commissioning, testing, maintenance and substation automation.

2. Main Features and Advantages of SIPROTEC 5

The SIPROTEC 5 platform offers several advantages for electrical utilities, industrial facilities, EPC contractors and power generation companies.

2.1 Modular Hardware and Software

One of the most important features of SIPROTEC 5 is its modular architecture.

Depending on the device type and selected configuration, engineers can configure:

  • Protection functions
  • Binary inputs and outputs
  • Analog current and voltage inputs
  • Communication interfaces
  • Ethernet modules
  • Additional hardware modules
  • Control and automation functions
  • Measurement and monitoring functions

This flexibility allows the protection system to be adapted to different applications without unnecessarily installing functions that are not required.

2.2 Advanced Protection Functions

SIPROTEC 5 devices provide a wide range of protection functions, depending on the relay model and selected configuration.

Examples include:

  • Phase overcurrent protection (50/51)
  • Earth-fault protection (50N/51N)
  • Directional overcurrent protection (67)
  • Distance protection (21)
  • Line differential protection (87L)
  • Transformer differential protection (87T)
  • Motor differential protection, where supported
  • Thermal overload protection (49)
  • Negative-sequence protection (46)
  • Under/overvoltage protection (27/59)
  • Under/overfrequency protection (81)
  • Breaker failure protection (50BF)
  • Automatic reclosing (79)
  • Synchrocheck (25)
  • Power swing detection and out-of-step protection, where supported

The available functions depend on the specific SIPROTEC 5 device, firmware, application and licensed/configured options.

2.3 IEC 61850 Communication and Substation Automation

SIPROTEC 5 is designed for integration into modern digital substations.

Its communication capabilities include:

  • IEC 61850 MMS
  • IEC 61850 GOOSE
  • IEC 61850-9-2 process bus applications
  • IEC 60870-5-103
  • IEC 60870-5-104
  • DNP3
  • Modbus TCP

Communication options depend on the device configuration and supported firmware.

IEC 61850 enables protection relays to exchange information with other intelligent electronic devices (IEDs), bay controllers, station controllers and SCADA systems.

For example, GOOSE communication can be used for interlocking, breaker failure initiation, protection signals and other high-speed substation automation applications.

2.4 Engineering with DIGSI 5

DIGSI 5 is the engineering software used to configure, parameterize, test and manage SIPROTEC 5 protection devices.

Using DIGSI 5, protection engineers can:

  • Create and manage SIPROTEC 5 projects
  • Configure device hardware
  • Select protection functions
  • Enter protection settings
  • Configure binary inputs and outputs
  • Create CFC logic diagrams
  • Configure communication parameters
  • Engineer IEC 61850 signals
  • Manage GOOSE communication
  • Configure protection and control logic
  • Perform device diagnostics
  • Read and analyze fault records
  • Test configured functions

Other important engineering tools include IEC 61850 System Configurator, SIGRA and SIPROTEC Web UI.

Understanding DIGSI 5 is essential for engineers working with SIPROTEC 5 protection relays.

3. SIPROTEC 5 Relay Models and Their Applications

The following sections introduce the main SIPROTEC 5 device types and their typical applications.

3.1 Overcurrent and Feeder Protection Relays

SIPROTEC 7SJ82, 7SJ85 and 7SJ86

Overcurrent protection is one of the most common protection applications in electrical power systems.

These devices are used to protect feeders, distribution lines, transformers and other electrical equipment against phase faults and earth faults.

SIPROTEC 7SJ82

The 7SJ82 is a compact overcurrent protection relay designed for medium-voltage and high-voltage feeder and line applications.

Typical applications include:

  • Medium-voltage feeder protection
  • Distribution network protection
  • Transformer backup protection
  • Capacitor bank protection
  • Industrial electrical distribution systems
  • Overcurrent and earth-fault protection

The 7SJ82 is particularly suitable for applications requiring a compact and cost-effective protection solution.

SIPROTEC 7SJ85

The 7SJ85 is a modular overcurrent protection relay designed for more flexible and demanding protection applications.

Typical applications include:

  • Medium-voltage and high-voltage feeder protection
  • Line overcurrent protection
  • Backup protection for transformers
  • Capacitor bank protection
  • Industrial power distribution
  • Protection and control integration

Its modular architecture allows engineers to configure the hardware and functions according to the project requirements.

SIPROTEC 7SJ86

The 7SJ86 is an overcurrent protection device intended particularly for line protection applications where additional measurement and monitoring capabilities, including PMU functionality, may be required.

Typical applications include:

  • Transmission and sub-transmission line protection
  • Overcurrent backup protection
  • Network monitoring
  • Power system measurement and synchrophasor applications

Important keywords: SIPROTEC 7SJ82, SIPROTEC 7SJ85, SIPROTEC 7SJ86, Siemens overcurrent relay, feeder protection relay, directional overcurrent protection, DIGSI 5 overcurrent relay configuration.

3.2 Motor Protection Relays

SIPROTEC 7SK82 and 7SK85

Electric motors are among the most important assets in industrial facilities, power plants, water treatment plants, oil and gas installations and manufacturing industries.

Motor protection relays monitor electrical and thermal operating conditions and detect abnormal operating situations.

SIPROTEC 7SK82

The 7SK82 is a compact motor protection relay designed primarily for small and medium-sized motors.

Typical applications include:

  • Medium-voltage motor protection
  • Industrial motor protection
  • Motor overload protection
  • Short-circuit protection
  • Earth-fault protection
  • Thermal monitoring
  • Starting and operating condition supervision

SIPROTEC 7SK85

The 7SK85 is a modular motor protection relay suitable for a broader range of motor applications, including demanding industrial installations.

Typical applications include:

  • Large industrial motor protection
  • Power plant auxiliary motor protection
  • Pump and compressor protection
  • Motor thermal protection
  • Motor starting supervision
  • Protection against unbalanced loading
  • Advanced motor monitoring

The 7SK85 is particularly relevant for engineers working with complex motor protection schemes.

Important keywords: SIPROTEC 7SK82, SIPROTEC 7SK85, Siemens motor protection relay, motor protection DIGSI 5, industrial motor protection, motor relay commissioning and testing.

3.3 Distance Protection Relays

SIPROTEC 7SA82, 7SA86 and 7SA87

Distance protection is widely used in transmission and sub-transmission networks to protect overhead lines and cables.

Distance relays determine the apparent impedance between the relay location and the fault location. By comparing the measured impedance with configured protection zones, the relay can identify faults within its protected line section.

SIPROTEC 7SA82

The 7SA82 is a distance protection relay designed for line protection applications.

Typical applications include:

  • Overhead transmission line protection
  • Sub-transmission line protection
  • Distance protection for electrical networks
  • Backup protection for transmission lines
  • Directional and distance-based fault detection

SIPROTEC 7SA86

The 7SA86 is a modular distance protection relay designed for demanding line protection applications.

Typical applications include:

  • Transmission line protection
  • High-voltage line protection
  • Multi-zone distance protection
  • Power system backup protection
  • Advanced protection and control schemes

SIPROTEC 7SA87

The 7SA87 is another advanced distance protection device in the SIPROTEC 5 family, intended for demanding transmission line applications.

Typical applications include:

  • High-voltage transmission line protection
  • Distance protection schemes
  • Advanced protection and monitoring
  • Network stability and synchrophasor applications, where configured

Engineers working with these relays should understand distance protection characteristics, impedance measurement, zone coordination, fault resistance, power swing blocking, load encroachment and automatic reclosing.

Important keywords: SIPROTEC 7SA82, SIPROTEC 7SA86, SIPROTEC 7SA87, Siemens distance protection relay, DIGSI 5 distance protection, transmission line protection, distance relay settings and commissioning.

3.4 Line Differential Protection Relays

SIPROTEC 7SD82, 7SD86 and 7SD87

Line differential protection is a selective protection method used to detect faults within a defined electrical line or cable protection zone.

The principle is based on comparing the currents measured at the different ends of the protected line.

Under normal operating conditions and for external faults, the differential current should remain within the expected stability limits.

For internal faults, the differential current increases and the protection system can issue a trip command.

SIPROTEC 7SD82

The 7SD82 is a line differential protection relay designed for overhead line and cable protection.

Typical applications include:

  • Transmission line differential protection
  • Distribution line differential protection
  • Cable differential protection
  • Internal phase-to-phase fault detection
  • Earth-fault detection
  • Main protection for electrical lines

SIPROTEC 7SD86

The 7SD86 is a modular line differential protection device for demanding protection applications.

Typical applications include:

  • High-voltage transmission lines
  • Cable protection
  • Multi-terminal line protection applications, where supported
  • Differential protection with additional backup functions
  • Advanced protection and monitoring

SIPROTEC 7SD87

The 7SD87 is an advanced line differential protection device for demanding transmission and sub-transmission applications.

It is particularly relevant for engineers working with complex line protection schemes.

Practical engineering knowledge should include:

  • Differential current calculation
  • Differential protection characteristics
  • CT ratio and polarity verification
  • Differential protection stability
  • Communication channel requirements
  • External and internal fault testing
  • Protection trip logic

Important keywords: SIPROTEC 7SD82, SIPROTEC 7SD86, SIPROTEC 7SD87, Siemens line differential relay, 87L protection, line differential protection settings, DIGSI 5 line differential configuration.

3.5 Combined Line Differential and Distance Protection

SIPROTEC 7SL82, 7SL86 and 7SL87

The SIPROTEC 7SL series combines line differential and distance protection within one protection device.

This provides an integrated solution for applications requiring both differential and distance-based protection principles.

SIPROTEC 7SL82

The 7SL82 is designed for combined line differential and distance protection applications.

Typical applications include:

  • Overhead line protection
  • Cable protection
  • Main and backup line protection
  • Medium-voltage and high-voltage line protection

SIPROTEC 7SL86

The 7SL86 is a modular combined line differential and distance protection device intended for demanding line protection applications.

SIPROTEC 7SL87

The 7SL87 is an advanced combined line differential and distance protection device for complex transmission line protection schemes.

Typical engineering topics include:

  • Distance protection zones
  • Line differential characteristics
  • Communication channel supervision
  • Differential protection stability
  • Backup protection coordination
  • Automatic reclosing
  • Protection and control logic

Important keywords: SIPROTEC 7SL82, SIPROTEC 7SL86, SIPROTEC 7SL87, combined line differential and distance protection, Siemens 7SL87 relay, DIGSI 5 7SL87 configuration.

3.6 Transformer Differential Protection Relays

SIPROTEC 7UT82, 7UT85, 7UT86 and 7UT87

Power transformers are critical components in transmission networks, distribution substations and power plants.

Transformer differential protection is one of the most important protection schemes used to detect internal transformer faults.

The SIPROTEC 7UT series provides transformer protection solutions for different applications and configurations.

SIPROTEC 7UT82

The 7UT82 is a compact transformer differential protection relay designed for transformer protection applications.

Typical applications include:

  • Two-winding transformer protection
  • Transformer differential protection
  • Transformer overcurrent backup protection
  • Industrial transformer protection
  • Distribution transformer protection

SIPROTEC 7UT85

The 7UT85 is a modular transformer differential protection relay.

It is suitable for more demanding transformer protection applications.

Typical applications include:

  • Power transformer protection
  • Transformer differential protection
  • Transformer backup protection
  • Transformer monitoring
  • Protection of multi-winding transformers, according to the configured application

SIPROTEC 7UT86

The 7UT86 is a modular transformer differential protection device designed for advanced applications.

It supports complex transformer protection schemes and additional protection and monitoring functions according to the selected configuration.

SIPROTEC 7UT87

The 7UT87 is an advanced transformer differential protection device for demanding power transformer protection applications.

Typical applications include:

  • Large power transformer protection
  • Multi-winding transformer protection
  • Transformer differential protection
  • Advanced protection and monitoring
  • Protection and control integration

Important topics for engineers working with the 7UT series include:

  • Transformer vector group compensation
  • CT ratio matching
  • Transformer differential current calculation
  • Inrush current detection
  • Overexcitation protection
  • Restricted earth-fault protection (REF)
  • Transformer thermal protection
  • Differential protection stabilization
  • Transformer backup protection

Important keywords: SIPROTEC 7UT82, SIPROTEC 7UT85, SIPROTEC 7UT86, SIPROTEC 7UT87, Siemens transformer differential relay, 87T protection, transformer REF protection, DIGSI 5 transformer protection settings.

3.7 Generator Protection Relay

SIPROTEC 7UM85

Generators require comprehensive protection against electrical faults and abnormal operating conditions.

The SIPROTEC 7UM85 is a modular generator protection relay designed for generator and power unit protection applications.

Typical applications include:

  • Synchronous generator protection
  • Power plant generator protection
  • Generator differential protection
  • Stator earth-fault protection
  • Rotor earth-fault protection, where configured
  • Loss of excitation protection
  • Reverse power protection
  • Negative-sequence protection
  • Overload and thermal protection
  • Overvoltage and undervoltage protection
  • Overfrequency and underfrequency protection

Generator protection engineering requires an understanding of the generator operating characteristics, stator and rotor protection principles, neutral grounding arrangements, CT and VT connections, and coordination between generator and transformer protection.

Important keywords: SIPROTEC 7UM85, Siemens generator protection relay, generator differential protection, stator earth fault protection, loss of excitation protection, generator protection DIGSI 5.

3.8 Generator Synchronization and Paralleling

SIPROTEC 7VE85

The SIPROTEC 7VE85 is a paralleling device designed to synchronize generators or power units with an electrical network, or to synchronize two power supply systems.

Typical applications include:

  • Generator synchronization
  • Power plant generator paralleling
  • Synchronization of electrical networks
  • Voltage matching
  • Frequency matching
  • Phase-angle supervision
  • Circuit-breaker closing supervision

Synchronization is essential to prevent electrical and mechanical disturbances when connecting generators to an energized power system.

Important keywords: SIPROTEC 7VE85, Siemens synchronizing relay, generator synchronization, generator paralleling, synchrocheck protection.

3.9 Busbar Protection Relay

SIPROTEC 7SS85

Busbars are critical components in electrical substations and power plants.

A fault on a busbar can result in the loss of several feeders, transformers or generating units. Therefore, fast and selective busbar protection is essential.

The SIPROTEC 7SS85 is a centralized busbar protection system designed for the detection and clearance of busbar faults.

Typical applications include:

  • Medium-voltage busbar protection
  • High-voltage busbar protection
  • Power plant busbar protection
  • Industrial substation busbar protection
  • Single-busbar arrangements
  • Double-busbar arrangements
  • Complex busbar configurations, according to the system design

Important engineering topics include:

  • Busbar zone configuration
  • CT connection and polarity
  • Differential protection principle
  • Check zone and zone selection
  • Disconnector position monitoring
  • CT saturation and stability
  • Circuit-breaker trip logic
  • Busbar protection testing

Important keywords: SIPROTEC 7SS85, Siemens busbar protection relay, busbar differential protection, 87B protection, DIGSI 5 7SS85 configuration, busbar protection commissioning.

3.10 Circuit-Breaker Management Device

SIPROTEC 7VK87

The SIPROTEC 7VK87 is a circuit-breaker management device designed for managing and supervising circuit-breaker applications.

It supports breaker-related control, monitoring and protection functions according to the selected application.

Typical applications include:

  • Circuit-breaker management
  • Breaker supervision
  • Breaker failure protection schemes
  • Breaker operating time monitoring
  • Trip and close circuit supervision
  • Circuit-breaker control and monitoring

Important keywords: SIPROTEC 7VK87, Siemens circuit breaker management, breaker failure protection, circuit breaker supervision relay.

3.11 Bay Controllers

SIPROTEC 6MD85 and 6MD86

Bay controllers are essential components of modern substation automation systems.

The SIPROTEC 6MD85 and 6MD86 are designed for bay-level control, monitoring, interlocking and automation applications.

Typical applications include:

  • Feeder bay control
  • Transformer bay control
  • Bus coupler bay control
  • Circuit-breaker control
  • Disconnector and earthing switch control
  • Electrical and mechanical interlocking
  • Measurement and monitoring
  • IEC 61850 substation automation

Bay controllers communicate with protection relays and other IEDs to provide coordinated control and monitoring of substation equipment.

Important keywords: SIPROTEC 6MD85, SIPROTEC 6MD86, Siemens bay controller, bay control unit, substation automation, IEC 61850 bay control.

3.12 Universal Protection Relays

SIPROTEC 7SX82, 7SX85 and 7SY82

The SIPROTEC universal protection family provides flexible protection solutions for medium-voltage applications.

SIPROTEC 7SX82

The 7SX82 is a compact universal protection device designed for a wide range of medium-voltage and distribution network applications.

Typical applications include:

  • Feeder protection
  • Line protection
  • Motor protection
  • Medium-voltage distribution
  • Protection and control integration

Its configurable functionality allows users to select the protection functions required for the specific application.

SIPROTEC 7SX85

The 7SX85 is a modular universal protection device designed for flexible and demanding applications.

It can be tailored to different protection requirements in medium-voltage networks.

SIPROTEC 7SY82

The 7SY82 is a universal protection device featuring a patented LPIT input concept.

It combines protection, automation and control functions for medium-voltage applications.

Typical applications include:

  • Medium-voltage feeder protection
  • Distribution network protection
  • Industrial switchgear
  • Integrated protection and automation

Important keywords: SIPROTEC 7SX82, SIPROTEC 7SX85, SIPROTEC 7SY82, Siemens universal protection relay, LPIT protection relay, medium-voltage protection.

3.13 High-Speed Busbar Transfer Device

SIPROTEC 7VU85

The SIPROTEC 7VU85 is associated with high-speed busbar transfer (HSBT) applications.

Busbar transfer systems are particularly important in power plants and industrial installations where uninterrupted supply to critical auxiliary loads is required.

For example, in a thermal power plant, critical auxiliary motors may normally be supplied from a unit transformer. If the unit supply becomes unavailable, the auxiliary bus can be transferred to an alternative healthy source.

A high-speed busbar transfer scheme aims to minimize the interruption time and reduce the risk of motor disconnection or process interruption.

Typical applications include:

  • Thermal power plant auxiliary systems
  • Industrial auxiliary power systems
  • Busbar source transfer
  • Transfer between unit and station transformers
  • Transfer between two independent power sources
  • Critical motor supply continuity

Important engineering topics include:

  • Fast transfer
  • In-phase transfer
  • Residual-voltage transfer
  • Dead-bus transfer
  • Breaker status monitoring
  • Voltage and frequency supervision
  • Transfer permissive logic
  • Interlocking and trip logic

The exact operating modes and capabilities must be verified against the selected device version and project configuration.

Important keywords: SIPROTEC 7VU85, Siemens high-speed busbar transfer, HSBT, busbar transfer scheme, power plant auxiliary bus transfer, automatic bus transfer.

3.14 Fault Recorder

SIPROTEC 7KE85

Fault recording is essential for understanding power system disturbances and analyzing protection system operation.

The SIPROTEC 7KE85 is a fault recording device used for recording electrical quantities and analyzing disturbances.

Typical applications include:

  • Substation disturbance recording
  • Power plant fault recording
  • Voltage and current waveform recording
  • Power quality analysis
  • Synchrophasor measurement applications, where configured
  • Post-fault analysis

Fault recordings help protection engineers investigate fault conditions, identify protection operation problems and improve system performance.

Important keywords: SIPROTEC 7KE85, Siemens fault recorder, disturbance recorder, power system fault analysis, SIGRA fault record analysis.

3.15 Merging Unit

SIPROTEC 6MU85

Merging units are important components of digital substations using process bus technology.

The SIPROTEC 6MU85 is a merging unit designed to interface primary instrument transformer measurements with digital substation systems.

Typical applications include:

  • Digital substation process bus
  • Current and voltage measurement acquisition
  • IEC 61850-9-2 applications
  • Sampled Values communication
  • Integration of primary equipment into digital protection systems

Merging units are particularly relevant for engineers working with IEC 61850 process bus architecture and digital substation design.

Important keywords: SIPROTEC 6MU85, Siemens merging unit, IEC 61850 process bus, Sampled Values, digital substation, IEC 61869.

3.16 Other SIPROTEC 5 Devices

The SIPROTEC 5 family includes additional device types for specialized protection and power system applications.

Examples include:

  • 7KE85: Fault recording and disturbance analysis.
  • 7VK87: Circuit-breaker management.
  • 7VE85: Generator synchronization and paralleling.
  • 7SS85: Centralized busbar protection.
  • 6MD85 / 6MD86: Bay control and substation automation.
  • 6MU85: Merging unit and process bus applications.

The device range is continually subject to product updates and configuration-specific changes. Always consult the applicable Siemens device documentation when selecting a relay for a project.

4. SIPROTEC 5 Relay Selection Guide

The following table provides a quick reference for selecting a SIPROTEC 5 device according to its main application.

SIPROTEC 5 modelMain application
7SJ82Compact overcurrent and feeder protection
7SJ85Modular overcurrent protection
7SJ86Overcurrent protection for lines
7SK82Compact motor protection
7SK85Modular motor protection
7SA82Distance protection
7SA86Modular distance protection
7SA87Advanced distance protection
7SD82Line differential protection
7SD86Modular line differential protection
7SD87Advanced line differential protection
7SL82Combined line differential and distance protection
7SL86Combined line differential and distance protection
7SL87Advanced combined line protection
7UT82Transformer differential protection
7UT85Modular transformer differential protection
7UT86Advanced transformer protection
7UT87Advanced transformer differential protection
7UM85Generator protection
7VE85Generator synchronization and paralleling
7SS85Busbar protection
7VK87Circuit-breaker management
6MD85Bay controller
6MD86Bay controller
6MU85Merging unit
7KE85Fault recorder
7SX82Universal protection
7SX85Modular universal protection
7SY82Universal protection with LPIT input
7VU85High-speed busbar transfer

This table summarizes the main application of each device; it is not a substitute for checking the detailed technical specifications and available protection functions.

5. SIPROTEC 5 and DIGSI 5 Engineering: What Should Protection Engineers Learn?

Knowing the model number of a protection relay is not enough to work confidently with SIPROTEC 5 devices.

Protection engineers need practical knowledge of protection principles, relay configuration, engineering software, communication, logic development and testing.

A professional SIPROTEC 5 training program should cover the complete engineering workflow.

5.1 DIGSI 5 Project Engineering

  • Creating a new DIGSI 5 project
  • Adding SIPROTEC 5 devices
  • Device selection and hardware configuration
  • Managing device variants
  • Parameterizing protection functions
  • Creating and managing device settings
  • Downloading configurations to IEDs
  • Online and offline engineering

5.2 Protection Function Configuration

  • Overcurrent protection configuration
  • Directional overcurrent protection
  • Distance protection configuration
  • Line differential protection
  • Transformer differential protection
  • Motor protection
  • Generator protection
  • Busbar protection
  • Breaker failure protection
  • Automatic reclosing
  • Voltage and frequency protection

5.3 CFC Logic Engineering

CFC (Continuous Function Chart) is an important part of SIPROTEC 5 engineering.

Engineers should understand how to:

  • Create CFC charts
  • Use logic blocks
  • Configure binary signals
  • Develop protection and control logic
  • Implement interlocking
  • Create trip and alarm logic
  • Configure timers and logic conditions
  • Test the implemented logic

5.4 IEC 61850 Engineering

Practical IEC 61850 knowledge is essential for modern SIPROTEC 5 projects.

Training should include:

  • IEC 61850 data models
  • Logical nodes and data objects
  • IEC 61850 System Configurator
  • GOOSE publisher and subscriber configuration
  • GOOSE signal mapping
  • SCL files
  • ICD, IID, CID and SCD files
  • MMS communication
  • SNTP time synchronization
  • Communication testing and diagnostics

5.5 Testing and Commissioning

The final stage is verifying that the relay operates correctly under actual and simulated fault conditions.

Engineers should learn:

  • Protection function testing
  • Binary input and output testing
  • Trip circuit verification
  • Circuit-breaker operation testing
  • CT and VT circuit verification
  • Protection logic testing
  • Communication testing
  • End-to-end protection testing, where applicable
  • Fault record analysis
  • Commissioning documentation

6. SIPROTEC 5 Relay Testing and Commissioning Training

Protection relay testing is a critical activity during factory acceptance testing (FAT), site acceptance testing (SAT), commissioning, maintenance and periodic protection system inspections.

Understanding how to configure a SIPROTEC 5 relay is only one part of the job. Engineers must also know how to verify the correct operation of the protection functions.

Our Relay Testing and Commissioning Training Course is designed to help electrical engineers develop practical knowledge of protection relay testing.

The course covers topics such as:

  • Introduction to protection relay testing
  • Primary injection and secondary injection testing
  • FAT and SAT procedures
  • CT and VT testing
  • CT ratio, polarity and wiring verification
  • Binary input and output testing
  • Circuit-breaker trip and close circuits
  • Protection function testing
  • Overcurrent relay testing
  • Distance relay testing
  • Differential protection testing
  • Transformer protection testing
  • Motor and generator protection testing
  • Protection logic and interlocking verification
  • Omicron CMC test equipment
  • OMICRON Test Universe
  • Test report preparation
  • Commissioning procedures and practical troubleshooting

The training is suitable for protection engineers, commissioning engineers, electrical maintenance engineers and technicians involved in protection system testing.

7. Advanced SIPROTEC 5 and DIGSI 5 Training by Elec-Engg

At Elec-Engg, we provide specialized training in power system protection, Siemens SIPROTEC protection relays and substation automation.

Our training is designed for engineers working in electrical utilities, power plants, industrial facilities, EPC companies and commissioning organizations.

We focus on practical engineering rather than simply explaining software menus or theoretical protection concepts.

Available Training Formats

1. Online SIPROTEC 5 Training

Live online training sessions based on the participant’s requirements.

Topics can include specific SIPROTEC 5 models, protection functions, DIGSI 5 engineering, CFC logic, IEC 61850 and practical troubleshooting.

2. Face-to-Face SIPROTEC 5 Training

Classroom and in-house training for companies, utilities and engineering teams.

Training content can be customized according to the company’s protection equipment, projects and engineering requirements.

3. Pre-Recorded SIPROTEC 5 Courses

Structured video training courses that engineers can access and study at their own pace.

These courses are suitable for engineers who prefer flexible learning and want to revisit technical lessons whenever necessary.

4. Customized Advanced SIPROTEC 5 Training

We also provide customized advanced training based on specific project requirements.

Possible topics include:

  • SIPROTEC 5 7SJ85 and 7SJ86 engineering
  • SIPROTEC 5 7SA86 and 7SA87 distance protection
  • SIPROTEC 5 7SD86 and 7SD87 line differential protection
  • SIPROTEC 5 7SL86 and 7SL87 combined line protection
  • SIPROTEC 5 7UT85, 7UT86 and 7UT87 transformer protection
  • SIPROTEC 5 7SS85 busbar protection
  • SIPROTEC 5 7UM85 generator protection
  • SIPROTEC 5 7SK85 motor protection
  • SIPROTEC 5 7VU85 high-speed busbar transfer
  • DIGSI 5 advanced engineering
  • CFC logic development
  • IEC 61850 and GOOSE engineering
  • Advanced protection testing and troubleshooting

The training program can be adapted to the experience level of the participants and the actual protection applications used in their projects.

8. Why Choose Elec-Engg for SIPROTEC 5 Training?

Our objective is to help protection engineers understand not only how to configure a relay but also why a protection function is required, how it operates and how it should be tested.

Our training approach emphasizes:

  • Practical protection engineering
  • Real-world electrical power system applications
  • Detailed explanations of protection principles
  • DIGSI 5 configuration and engineering
  • IEC 61850 communication and substation automation
  • Protection logic and CFC applications
  • Relay testing and commissioning
  • Advanced troubleshooting and fault analysis

Whether you are a beginner starting with SIPROTEC 5 or an experienced protection engineer looking to improve your advanced DIGSI 5 engineering skills, we can develop a suitable training program.

9. Contact Us for SIPROTEC 5 and Relay Testing Training

Are you looking for professional Siemens SIPROTEC 5 training, DIGSI 5 engineering courses, advanced protection relay training or relay testing and commissioning courses?

Contact Elec-Engg to discuss your requirements.

We provide:

  • Online SIPROTEC 5 training
  • Face-to-face SIPROTEC 5 training
  • Pre-recorded SIPROTEC 5 courses
  • Customized advanced DIGSI 5 training
  • Protection relay testing and commissioning training
  • Customized corporate and in-house training

Training can be arranged according to your preferred relay models, engineering requirements and experience level.

Contact us to discuss your training requirements and receive further information.

Website: https://elec-engg.com/

Elec-Engg – Practical Training in Power System Protection and Substation Automation.


Frequently Asked Questions (FAQ)

1. What is Siemens SIPROTEC 5?

SIPROTEC 5 is a family of digital protection, control, automation and monitoring devices developed by Siemens for electrical power systems. It is used in substations, power plants, transmission networks, distribution systems and industrial installations.

2. What is the difference between SIPROTEC 4 and SIPROTEC 5?

SIPROTEC 5 is a newer and more modular protection platform. It provides flexible hardware and software configurations, advanced engineering capabilities through DIGSI 5, and extensive communication and automation functions. SIPROTEC 4 devices are engineered using DIGSI 4.

3. Which SIPROTEC 5 relay is used for overcurrent protection?

The main overcurrent protection devices include 7SJ82, 7SJ85 and 7SJ86.

4. Which SIPROTEC 5 relay is used for distance protection?

The main distance protection devices are 7SA82, 7SA86 and 7SA87.

5. Which SIPROTEC 5 relay is used for line differential protection?

The 7SD82, 7SD86 and 7SD87 are designed for line differential protection.

6. Which SIPROTEC 5 relay provides combined distance and differential protection?

The 7SL82, 7SL86 and 7SL87 combine distance and line differential protection functions.

7. Which SIPROTEC 5 relay is used for transformer differential protection?

The 7UT82, 7UT85, 7UT86 and 7UT87 are transformer protection devices.

8. Which SIPROTEC 5 relay is used for motor protection?

The 7SK82 and 7SK85 are the main dedicated motor protection devices.

9. Which SIPROTEC 5 relay is used for generator protection?

The 7UM85 is designed for generator protection applications.

10. Which SIPROTEC 5 relay is used for busbar protection?

The 7SS85 is designed for centralized busbar protection.

11. Which software is used to configure SIPROTEC 5 relays?

DIGSI 5 is the main engineering software for configuring, parameterizing and managing SIPROTEC 5 protection devices.

12. Does Elec-Engg provide advanced SIPROTEC 5 training?

Yes. Elec-Engg provides online, face-to-face, pre-recorded and customized advanced SIPROTEC 5 and DIGSI 5 training, as well as protection relay testing and commissioning courses. Contact us to discuss your requirements.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top