GE Multilin Protection Relay Product Families and Applications: Complete Technical Comparison

1. Introduction

GE Multilin is a well-established name in electrical power system protection, control and monitoring. Its protection relay portfolio covers applications ranging from industrial motor protection and distribution feeder protection to complex transmission line, transformer, generator and busbar protection schemes.

Selecting the correct protection relay is an important engineering decision. The selected device must satisfy the protection philosophy, electrical characteristics, system configuration, communication requirements and operational needs of the installation.

GE Multilin offers several protection relay families, each developed for particular applications and engineering requirements.

This article provides an overview of the major GE Multilin relay families, their applications, important models and differences.

2. GE Multilin Relay Families

The GE Multilin portfolio includes several important product groups:

  1. Universal Relay (UR) family
  2. GE Multilin 8 Series
  3. Distribution protection relays
  4. Industrial motor protection relays
  5. Feeder protection and automation relays
  6. Specialized protection and control devices

These platforms differ in hardware architecture, protection capabilities, communication options, configuration methods and application flexibility.

3. GE Multilin Universal Relay (UR) Family

The Universal Relay family is a modular numerical protection platform designed for demanding utility and industrial applications.

UR relays combine multiple protection functions with programmable logic, monitoring, metering, disturbance recording and communication capabilities.

3.1 Important UR Relay Models

ModelMain application
T60Transformer protection
T35Transformer protection
D60Distance protection
D30Distance protection
L90Line differential protection
L60Phase comparison protection
G60Generator protection
G30Generator and transformer protection
F60Feeder protection
F35Multiple feeder protection
B90Busbar protection
B30Busbar protection
M60Motor protection
C60Breaker management
C30I/O and logic control
C70Capacitor bank protection

3.2 Main Characteristics

The UR family is particularly suitable for projects requiring advanced protection and flexible engineering.

Important capabilities include:

  • Comprehensive protection functions
  • Programmable FlexLogic
  • Configurable binary inputs and outputs
  • Disturbance recording
  • Event recording
  • Advanced metering
  • Communication capabilities
  • IEC 61850 integration on supported configurations
  • Protection and control integration

3.3 Engineering Applications

UR relays are frequently considered for:

  • High-voltage substations
  • Power generation plants
  • Industrial substations
  • Transformer protection panels
  • Transmission line protection panels
  • Busbar protection systems
  • Critical industrial motors

4. GE Multilin 8 Series

The GE Multilin 8 Series is a modern protection and control platform designed for electrical distribution, transformers, motors and generators.

Important products include:

4.1 Multilin 845 – Transformer Protection

The 845 provides transformer protection and monitoring functions.

Typical applications include:

  • Transformer differential protection
  • Restricted earth fault protection
  • Overcurrent protection
  • Thermal protection
  • Transformer monitoring
  • Protection logic and control

4.2 Multilin 850 – Feeder Protection

The 850 is designed for feeder protection and control.

Applications include:

  • Distribution feeder protection
  • Industrial feeder protection
  • Overcurrent protection
  • Directional protection
  • Earth fault protection
  • Voltage and frequency protection
  • Circuit breaker control

4.3 Multilin 869 – Motor Protection

The 869 provides comprehensive motor protection and management.

Typical applications include:

  • Large industrial motors
  • Critical process motors
  • Pumps and compressors
  • Fans and blowers
  • Industrial drives

4.4 Multilin 859 – Compact Motor Protection

The 859 is designed for motor protection applications requiring a compact protection solution.

4.5 Multilin 889 – Generator Protection

The 889 is designed for generator protection applications, providing protection, monitoring and control capabilities.

5. GE Multilin Distribution and Industrial Protection Relays

GE Multilin also provides several established protection products for distribution and industrial applications.

5.1 Multilin 350 – Feeder Protection

The 350 is used for distribution feeder protection and control.

Typical functions include:

  • Phase overcurrent
  • Ground overcurrent
  • Voltage protection
  • Frequency protection
  • Breaker failure protection
  • Reclosing, where supported

5.2 Multilin 339 – Motor Protection

The 339 is designed for motor protection in industrial installations.

5.3 Multilin 369 – Motor Protection

The 369 is an established motor protection relay used for monitoring and protecting industrial motors.

5.4 Multilin 469 – Motor Management

The 469 provides advanced motor protection and management capabilities for industrial applications.

5.5 Multilin F650 – Feeder Protection and Automation

The F650 provides feeder protection, control and automation functionality.

It is suitable for applications requiring integration of protection and substation control functions.

6. Comparison of Major GE Multilin Relay Families

Relay familyMain applicationsEngineering focus
URTransmission, generation and industrialAdvanced protection and programmable logic
8 SeriesTransformers, feeders, motors, generatorsModern protection and control
350Distribution feedersFeeder protection
339Industrial motorsMotor protection
369Industrial motorsMotor protection and monitoring
469Critical motorsAdvanced motor management
F650Distribution substationsFeeder protection and automation

This comparison is intended as a product-family overview. Exact functions, communication protocols and hardware options must be checked against the relevant model documentation and firmware.

7. How to Select the Correct GE Multilin Relay

Relay selection should be based on the electrical application and protection requirements rather than simply choosing the newest or most advanced device.

The following factors should be considered.

7.1 Protected Equipment

Identify whether the relay will protect:

  • Transformer
  • Generator
  • Motor
  • Feeder
  • Transmission line
  • Busbar
  • Capacitor bank

7.2 Required Protection Functions

Prepare a protection function list based on the protection philosophy and applicable standards.

For example, a transformer protection scheme may require:

  • 87T – Transformer differential
  • 64REF – Restricted earth fault
  • 50/51 – Phase overcurrent
  • 50N/51N – Earth fault
  • 49 – Thermal overload
  • 24 – Overexcitation

7.3 CT and VT Requirements

Verify:

  • CT primary and secondary ratings
  • CT core allocation
  • CT accuracy class
  • CT polarity
  • VT ratio
  • Voltage input configuration
  • Required measurement channels

7.4 Communication Requirements

Consider the required communication protocols:

  • IEC 61850
  • Modbus
  • DNP3
  • IEC 60870-5-103
  • Ethernet
  • Serial communication

Check the specific relay’s supported protocols and optional hardware.

7.5 Binary Inputs and Outputs

Verify the number and type of required binary inputs and outputs.

Typical applications include circuit breaker status, trip commands, closing commands, interlocking, alarms and external protection signals.

7.6 Engineering and Maintenance

Consider:

  • Available engineering software
  • Firmware compatibility
  • Settings management
  • Testing requirements
  • Spare parts availability
  • Technical support
  • Long-term maintenance strategy

8. GE Multilin Relay Engineering Workflow

A typical engineering workflow includes the following stages:

  1. Review the single-line diagram.
  2. Identify the protected equipment.
  3. Define the protection philosophy.
  4. Select the appropriate relay model.
  5. Review hardware and I/O requirements.
  6. Calculate protection settings.
  7. Configure the relay using the applicable EnerVista software.
  8. Configure protection logic and control functions.
  9. Configure communication and IEC 61850, where required.
  10. Perform secondary injection tests.
  11. Verify trip and interlocking circuits.
  12. Complete commissioning documentation.

9. Training on GE Multilin Protection Relays by Elec-Engg

Understanding GE Multilin protection relays requires more than familiarity with product catalogues. Protection engineers need practical knowledge of relay configuration, protection settings, logic engineering, communication, testing and troubleshooting.

Elec-Engg provides practical power system protection and substation automation training by Dr Saeed Roostaee (Electrical Engineering).

Our training approach focuses on real engineering applications and practical understanding of numerical protection relays.

Relevant training areas include:

GE Multilin Protection Relay Training

  • Introduction to GE Multilin protection relay families
  • Understanding relay hardware and architecture
  • Protection functions and ANSI device numbers
  • CT and VT configuration
  • Protection settings and calculations
  • Relay configuration using EnerVista software
  • FlexLogic programming
  • Event and disturbance record analysis
  • Communication configuration
  • IEC 61850 engineering
  • GOOSE communication
  • Relay testing and commissioning
  • Troubleshooting practical protection problems

Training can be tailored to specific GE Multilin models and project requirements, subject to the availability of the relevant relay documentation, software and hardware.

Our Training Formats

  • Online video training
  • Structured self-paced technical training
  • Live online training
  • Face-to-face technical training
  • Customized in-house training for companies and utilities

Our objective is to help engineers understand not only how a relay operates, but also how to configure, test, commission and troubleshoot it in real electrical power systems.

Explore our training programs: https://elec-engg.com/

Contact Elec-Engg: https://elec-engg.com/contact/

10. Conclusion

GE Multilin provides a broad portfolio of protection and control relays for transmission, distribution, generation and industrial applications.

The UR family provides advanced protection and flexible engineering capabilities, while the 8 Series offers modern protection solutions for transformers, feeders, motors and generators. Other Multilin products address specialized distribution and industrial requirements.

A proper understanding of relay families, protection functions, engineering software, communication and commissioning procedures is essential for successful protection system implementation.

In the next article, we will examine the internal architecture of GE Multilin numerical protection relays, including analog inputs, processors, binary inputs and outputs, communication modules and protection processing.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top