- Online+ Pre-recorded Training
- 3-5 April 2024
- 22-24 March 2024
- Pre-requisite training: DIGSI 4, DIGSI 5, IEC61850
- Language: English
- Supporting Files
- Trainer: Dr. Saeed Roostaee (Profile)
- Limited seats available
- Registration link: expired
Module I: Substation Automation System
- Substation Automation System-an overview
- Introduction to Communication
- Network Theory
- Fundamentals of Communication Via Ethernet Various Topologies in SIEMENS SAS
Module II: Bay Level Engineering (IEC 61850 and Modbus)
- Add SIPROTEC 4 6MD66 device
- Setting the Network Parameters
- 6MD configuration
- IEC61850 Configuration
- Updating ICD – Files
Module III: Station Level Engineering SICAM PAS
- Introduction to SICAM PAS Automation System
- SICAM PAS Tasks
- Fields of Application
- SICAM PAS Features
- Scalability – Software and Hardware Configuration for Small to Large Applications
- Basic Package “ Full Server”
- SICAM PAS Packages (IEC 61850, Profibus FMS (SICAM/SIPROTEC specified protocols), IEC 60870-5-103, DNP V3.00, Profibus DP, Modbus, ILSA (Internal LSA protocol, OPC-Client, Automation CFC)
- Licensing
- Licensing With Feature Enabler
- IEC 61850 Services in IEDs and SICAM PAS
- SICAM PAS Configuration (Working with Project Databases, Creating a New Database, Adding and Managing Systems, Adding an Application (IEC 61850 Client), Importing a SCD file, Updating One or Several Device(s), Adding ModbusApplication, Parameterizing ModbusApplication, Added EMA90 ModbusMap, Defining the Device Template (ModbusMap), Adding IEC 60870-5-101 Slave Application, Inserting the Control Center of IEC 60870-5-101 Slave, Inserting the SNMP Application, Monitoring IEC 61850 IEDs Connection Status With SNMP, Inserting a PASCC Application to Full Server System, Inserting Control Center to PASCC Application, Inserting a PASCC to a New System (DIP)
- Creating a CFC file
- Human-Machine Control Center Mapping, Exporting of HMI1 Interface
- Normalization
- Create a Normalization Template
- Scaling a measured value
- Assignment of normalization in Mapping
- Archiving Configured Project, Un-archiving Project
- SICAM PAS Value Viewer
- Control function
- Testing data
- ValueViewer: Communication diagnostics
Module IV: SICAM SCC
- Export of HMI information from SICAM PAS
- Check the content of a PXD file
- Introduction to SICAM PASCC Control Center
- SICAM PASCC Control Center ‐ Overview
- SIMATIC WinCC
- SICAM PASCC Components
- SICAM PASCC Communication
- SICAM PAS Wizard
- WinCC Explorer
- Graphic Objects Library
- Switchgear Objects
- Schwitchgear Objects – Styles and States
- Alarm Logging – Message List
- Control & Monitoring
- WinCC & PASCC Licensing
- SIMATIC WinCC / SICAM PASCC Installation Steps
- Transfer The License Keys
- SIMATIC WinCC / SICAM PASCC Time Synchronization & NTP
- SICAM PASCC Starting The WinCC/PASCC Software
- SICAM PASCC Creating/ Opening a New Project
- SICAM PASCC Defining The Computer Properties General Tab, Startup Tab, Parameters Tab, Graphics Runtime Tab
- Adding a Communication Driver
- Connection Properties
- Entering the IP Address of SICAM PAS Servers
- Error Log File of SICAM PAS Wizard
- Select the Right SICAM PAS Protocol Suite
- Set PAS IP Connection
- Importing of the Sample Pilot Project .pxd File
- Checking Structure Tags of a New Project
- Structure Tag Elements
- Symbol Library
- SICAM Administrative Internal Tags
- Schwitchgear Objects – Tag Connection
- Design of Graphical Objects
- Switchgear Objects – Sychro-Check
- Alarm Logging – Events & Alarms
- Alarm Logging – Message Queue & Mes Ack Tags
- Tag Logging – Measured Values
- WinCC Horn Tools– Sound File
- Tag Logging – Archive Configuration
- Trends Picture
- Topological coloring
- Event List
- Alarm List
- Protection Message List
- Horn, Alarm Acknowledgment
- Creating an Event List in the Graphics Designer
- User Administrator
- Login via button
- Report Designer – Print Job
- Project Archive, Duplicator
- Bay Blocking