IEC 61850-9-2 Process bus equipment

IEC 61850-9-2 Process Bus Equipment: Merging Units, Sampled Values & Digital Substations

Process bus technology is a fundamental part of modern digital substations. It enables the transmission of digitized current and voltage measurements from instrument transformers to protection, control, and measurement IEDs using Ethernet communication networks.

One of the key components of an IEC 61850 process bus architecture is the Merging Unit (MU).

AMU – IEC 61850 Merging Unit

The AMU is a Merging Unit designed for digital substations. It publishes measurement data over the substation process bus in accordance with IEC 61850-9-2LE or IEC 61869-9 standards.

The measurement data is transmitted as Sampled Values (SV), allowing protection and control IEDs to receive digitized current and voltage signals through an Ethernet-based process bus network.

Main Features and Capabilities

  • IEC 61850-9-2LE Sampled Values publishing.
  • IEC 61869-9 standard compliance.
  • IEC 61850 GOOSE messaging support.
  • Process bus communication for digital substations.
  • High-accuracy time synchronization.
  • Support for PPS and IRIG-B synchronization.
  • NTP and IEEE 1588 Precision Time Protocol (PTP).
  • Local clock synchronization.
  • Internal GPS receiver for time synchronization.

Time Synchronization in Digital Substations

Accurate time synchronization is essential for Sampled Values applications, particularly when multiple Merging Units and protection IEDs operate within the same process bus architecture.

Depending on the configuration, the AMU supports different synchronization methods, including:

  • PPS (Pulse Per Second)
  • IRIG-B
  • NTP (Network Time Protocol)
  • PTP (IEEE 1588)
  • Internal GPS receiver
  • Local clock

IEC 61850 Process Bus Applications

Merging Units are used to digitize analog current and voltage measurements and transmit them to protection and control devices through the process bus.

Typical applications include:

  • Digital current and voltage measurement.
  • Sampled Values communication.
  • Protection IED integration.
  • Process bus architecture engineering.
  • Digital substation commissioning.
  • IEC 61850 GOOSE and SV communication.
  • Replacement of conventional copper wiring between instrument transformers and protection panels.

Understanding the operation, configuration, and testing of Merging Units is an important skill for engineers working with IEC 61850 digital substations.

IEC 61850 Training by Elec-Engg

Elec-Engg provides practical IEC 61850 training covering digital substation engineering, communication, and integration.

Our IEC 61850 Video Training Package covers important topics such as:

  • IEC 61850 fundamentals and architecture.
  • Logical Nodes and Logical Devices.
  • GOOSE messaging.
  • Sampled Values and process bus.
  • Merging Units.
  • SCL files and system configuration.
  • IED integration and communication testing.
  • Practical engineering using relevant software tools.

Explore our training package:

https://elec-engg.com/iec-61850-training-course

Elec-Engg provides practical training through online courses, structured self-paced programs, face-to-face training, and customized in-house technical training.

IEC 61850-9-2 Process bus equipment

The AMU is a Merging Unit in a digital substation that can publish messages over the substation process bus in compliance with the IEC 61850-9-2LE or IEC61869-9 standard. Data is published in the form of sampled values (SV) that comply with the light edition (LE) of the IEC 61850-9-2.  And it has high accuracy time synchronization via PPS or IRIG-B, NTP, PTP1588, local clock, or via its internal built-in GPS receiver. It Complies with: IEC 61850-9-2LE and IEC 61850 GOOSE messaging. Also complies with the new IEC 61869-9 standard.

IEC61850 Video Training Package

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top