MiCOM Protection Relays: Complete Guide to Models, Functions & Applications

Introduction to MiCOM Protection Relays

MiCOM is a well-established family of numerical protection and control devices used in electrical power systems, industrial installations, transmission networks and distribution substations.

Originally associated with ALSTOM and AREVA, the MiCOM relay portfolio is now part of Schneider Electric’s protection and control product offering. It includes protection solutions for feeders, motors, generators, transformers, transmission lines and busbars.

MiCOM numerical relays combine protection, measurement, monitoring, control, communication and disturbance recording capabilities in compact Intelligent Electronic Devices (IEDs).

They are widely used by utilities, industrial facilities, power plants, substations and engineering contractors.

1. What Is a MiCOM Protection Relay?

A MiCOM protection relay is a numerical microprocessor-based device designed to continuously monitor electrical quantities such as:

  • Phase currents.
  • Residual and earth-fault currents.
  • Phase-to-phase and phase-to-earth voltages.
  • Frequency.
  • Active and reactive power.
  • Power factor.
  • Impedance and apparent resistance.
  • Negative- and zero-sequence quantities.

The relay processes these measurements and compares them against configured protection settings.

When an abnormal electrical condition is detected, the relay initiates the appropriate protection operation, such as issuing a trip command to the associated circuit breaker.

Depending on the model, MiCOM relays also provide:

  • Circuit breaker control and monitoring.
  • Auto-reclosing.
  • Synchronism checking.
  • Event recording.
  • Disturbance recording.
  • Programmable logic.
  • Communication with SCADA systems.
  • IEC 61850 substation integration.

2. MiCOM Protection Relay Product Families

MiCOM relays are organized into different model families according to their applications.

Relay familyMain application
P11x / P12xBasic overcurrent and earth-fault protection
P13x / P14xFeeder protection and management
P21x / P22x / P24xMotor protection
P34xGenerator protection
P43x / P44xDistance protection
P52x / P53x / P54xLine differential protection
P63x / P64xTransformer differential protection
P72x / P74xBusbar protection
P821 / P84xBreaker failure and related protection/control
P92xVoltage and frequency protection

The exact protection functions depend on the individual relay model, hardware version and software configuration.

3. Main Protection Functions Available in MiCOM Relays

MiCOM relays provide a wide range of protection functions. Some of the most important functions include:

ANSI codeProtection function
21Distance protection
24Overexcitation protection
25Synchronism check
27Undervoltage
32Directional power
37Undercurrent
40Loss of excitation
46Negative-sequence protection
49Thermal overload
50Instantaneous overcurrent
51Time overcurrent
50N/51NEarth-fault overcurrent
50BFCircuit breaker failure
59Overvoltage
67Directional overcurrent
78Out-of-step protection
79Auto-reclosing
81Frequency protection
87BBusbar differential
87LLine differential
87TTransformer differential

Not every MiCOM relay includes all these functions. Selection depends on the protected equipment and required protection philosophy.

4. MiCOM Relays in Electrical Substations

MiCOM relays are commonly installed in medium-voltage, high-voltage and extra-high-voltage substations.

Typical applications include:

Feeder protection

Protection against phase faults, earth faults, overloads and other abnormal operating conditions.

Transformer protection

Differential protection, restricted earth fault protection, overcurrent backup protection and thermal protection.

Transmission line protection

Distance protection, line differential protection, directional overcurrent protection and auto-reclosing.

Busbar protection

High-speed detection of internal busbar faults using differential protection principles.

Motor protection

Protection against overload, short circuit, earth fault, locked rotor, unbalance and abnormal operating conditions.

Generator protection

Protection against stator faults, rotor-related abnormalities, loss of excitation, reverse power and other generator operating conditions.

5. MiCOM Relay Configuration and Engineering Software

Engineering software is an important part of MiCOM protection relay applications.

Two important software platforms are:

MiCOM S1 Studio

MiCOM S1 Studio is used for engineering and managing supported MiCOM protection devices. Depending on the relay and software version, it provides facilities for:

  • Relay setting configuration.
  • Parameterization.
  • Disturbance and event record retrieval.
  • Communication configuration.
  • Relay project management.
  • Device maintenance.

Easergy Studio

Easergy Studio is another engineering environment used for supported Schneider Electric protection and control devices.

Software compatibility must always be checked against the specific relay model, firmware and hardware generation.

6. IEC 61850 and MiCOM Substation Automation

Modern MiCOM protection devices can be integrated into Substation Automation Systems (SAS).

Depending on the model and communication options, integration may include:

  • IEC 61850 communication.
  • GOOSE messaging.
  • MMS client/server communication.
  • Logical nodes and data objects.
  • Substation Configuration Language (SCL).
  • Station bus engineering.
  • SCADA communication.
  • Time synchronization.
  • Event and alarm monitoring.

GOOSE communication can be used for fast peer-to-peer signal exchange between IEDs, for example, interlocking, breaker failure initiation and protection intertripping.

Proper configuration and testing of IEC 61850 communication are essential for reliable substation operation.

7. MiCOM Protection Relay Testing and Commissioning

Testing and commissioning are essential activities before putting a protection relay into service.

Typical activities include:

  1. Checking relay hardware and auxiliary supply.
  2. Verifying CT and VT connections.
  3. Checking CT polarity and ratios.
  4. Reviewing protection settings.
  5. Testing overcurrent and earth-fault elements.
  6. Testing directional protection.
  7. Testing differential protection where applicable.
  8. Checking binary inputs and outputs.
  9. Verifying circuit breaker trip and close circuits.
  10. Testing communication and SCADA signals.
  11. Verifying disturbance and event recording.
  12. Performing complete functional and trip testing.

Omicron CMC test equipment and Test Universe software can be used for secondary injection testing of MiCOM protection relays.

The test procedure must be developed according to the relay model, protection functions and project requirements.

8. Why Engineers Should Learn MiCOM Protection Relays

Understanding MiCOM relays is valuable for engineers involved in:

  • Electrical power system protection.
  • Protection and control engineering.
  • Substation commissioning.
  • Relay testing and maintenance.
  • Industrial power systems.
  • Transmission and distribution networks.
  • Substation automation and IEC 61850.
  • Protection coordination and grading.

Practical knowledge of relay settings, configuration, testing and troubleshooting helps engineers work more effectively with installed protection systems.

9. MiCOM Protection Relay Training by Elec-Engg

Elec-Engg provides specialized technical training in power system protection, numerical protection relays and substation automation.

Our training programs are designed for electrical engineers working in utilities, power plants, industrial facilities, engineering companies and commissioning contractors.

Available training methods include:

  • Online training: Structured technical courses with practical engineering examples.
  • Self-paced training: Learn at your own schedule with organized lessons and technical materials.
  • Face-to-face training: Practical classroom training for engineers and technical teams.
  • Customized in-house training: Training programs developed according to the client’s installed MiCOM relay models, protection schemes and engineering requirements.

Our technical training subjects include MiCOM P14x feeder protection, P24x motor protection, P34x generator protection, P44x distance protection, P54x line differential protection and P64x transformer protection.

We also provide training in relay configuration, protection settings, secondary injection testing, commissioning procedures, fault analysis and IEC 61850 substation automation.

For information about MiCOM relay training, customized courses and technical support, contact Elec-Engg.

Conclusion

MiCOM protection relays provide a comprehensive range of protection, control, monitoring and communication solutions for electrical power systems.

From basic feeder overcurrent protection to advanced distance, line differential, transformer differential and busbar protection, the MiCOM portfolio supports many different substation and industrial applications.

Understanding the individual relay models, their protection functions, configuration software and testing procedures is essential for protection engineers and commissioning professionals.

Follow the Elec-Engg MiCOM article series for detailed technical guides covering individual MiCOM relay models, protection functions, configuration, settings, testing and commissioning.