DIgSILENT Training
Main Training (Pre-recorded sections)
- P 01 (6 min, April 08, 2022): Course Contents and details
- P 02 (11 min, April 08, 2022): Introducing DIgSILENT
- P 03 (6 min, April 08, 2022): Comparision of common power system study software
- P 04 (7 min, April 08, 2022): Brief overview of DIgSILENT environment
- P 05 (11 min, April 08, 2022): DIgSILENT menu
- P 06 (13 min, April 08, 2022): DIgSILENT menu
- P 07 (17 min, April 08, 2022): Study tools in DIgSILENT
- P 08 (08 min, April 08, 2022): Creating a simple 3-bus system in DIgSILENT
- P 09 (17 min, April 08, 2022): Line/cable modeling and parameters
- P 10 (8 min, April 08, 2022): Generator modeling and parameters
- P 11 (7 min, April 08, 2022): Transformer modeling and parameters
- P 12 (9 min, April 08, 2022): Loads and busbar modeling and parameters
- P 13 (11 min, April 12, 2022): DIgSILENT Graphics, tools, and applications
- P 14 (12 min, April 12, 2022): DIgSILENT Graphics, tools, and applications
- P 15 (5 min, April 12, 2022): DIgSILENT Graphics, tools, and applications
- P 16 (10 min, April 12, 2022): Elements in DIgSILENT
- P 17 (8 min, April 12, 2022): Different scenarios, case studies, Variations
- P 18 (7 min, April 12, 2022): Different scenarios, case studies, Variations
- P 19 (10 min, April 16, 2022): Equipment modeling; External Grid
- P 20 (6 min, April 16, 2022): Load
- P 21 (4 min, April 16, 2022): Breaker/switch
- P 22 (12 min, April 12, 2022): Synchronous generator
- P 23 (6 min, April 16, 2022): Transformer
- P 24 (11 min, April 16, 2022): Line
- P 25 (7 min, April 16, 2022): Cable and Shunt/filter C or capacitor bank
- P 26 (16 min, April 21, 2022): Power flow study; Study setting
- P 27 (16 min, April 21, 2022): Power flow study; Different output and reporting
- P 28 (15 min, April 21, 2022): N-1 study; Study setting
- P 29 (14 min, April 21, 2022): N-1 study; Different output and reporting
- P 30 (15 min, April 22, 2022): Short-circuit study; Study setting
- P 31 (12 min, April 22, 2022): Short-circuit study; Different output and reporting
- P 32 (18 min, April 22, 2022): Transient study; Defining different events; Study setting
- P 33 (20 min, April 22, 2022): Transient study; Study setting; Different output and reporting
Protection study Course Details:
- Part 1 and part 2 (26 min): Review the protections capabilities; Graphical properties; Definition of relays and slots; Definition of CT and its details; Describe the protection modeling concept Model an overcurrent relay
- Part 3 (10 min): Definition of PT and its details; Apply protection settings; Introduce DSL of relays Model a distance relay
- Part 4 (4 min): Create a PSLD; Create a time-overcurrent plot; Create an R-X plot
- Part 5 (17 min): Example of applying overcurrent relays on a radical system and their coordination
- Part 6 (15 min): Continue overcurrent coordination; Change the relay setting in plots Time-overcurrent plot setting
- Part 7 (23 min): Continue overcurrent coordination
- Part 8 (7 min): Continue overcurrent coordination
- Part 9 (16 min): Distance relay settings and coordination
- Part 10 (19 min): Continue Distance relay settings and coordination
- Part 11 (18 min): Continue Distance relay settings and coordination
- Part 12 (21 min): Continue Distance relay settings and coordination
- Part 13 (17 min): Study of the Over-voltage and under-voltage Protection Functions in DIgSILENT
- Part 14 (16 min): Study of the over-frequency and under-frequency
- Part 15 (14 min): Continue the over-frequency and under-frequency load shedding (UFLS) scheme
- Part 16 (16 min): Directional overcurrent
- Part 17 (14 min): Fuse
Supplementary files:
- DIgSilent PowerFactory 15 User Manual
- Load Flow Analysis in DIgSILENT PowerFactory
- Load Flow and Dynamic Simulation with the Palau Grid
- Load Flow and Short Circuit Calculation (Training Material)
- Load flow Calculations (Training Course)
- DIgSILENT Programming Language (DPL)
- DPL Tutorial
- Distance Protection Tutorial
- Detailed Modelling of HV Single-Core Cale Systems
- Compatibility Issues in Time Domain Simulations with DIgSILENT PowerFactory and SIEMENS PSSE
- Cable Modelling Tutorial
- Relay Modelling
- DPL Function Reference
- Dynamic Modelling Tutorial
- Advanced Smart Grid Functionalities Based on PowerFactory
- Short-Circuit Calculations (Training Course)
- Dynamic Wind Turbine Models in Power System Simulation tool DIgSILENT
- Grid Connection of WindFarms
- Implementation of the Model of a Solar Inverter
- Improving the Photovoltaic Model in PowerFactory
- Exercises for the Power System Stability
- Grid Compatibility of Wind Generators with Hydro-Dynamically Controlled Gearbox with German Grid Codes
- DIgSILENT PowerFactory Model Documentation IEC 61400-27-1 WTG Models
- Multicore Simulation of Power System Transients
- Over-Current Protection Tutorial
- Power System Stability on Island Networks
- Power Systems Electromagnetic Transients Simulation
- PowerFactory Applications for Power System Analysis (Springer)
- Python Advanced Tutorial
- Synchronous Generator (Training Course)
- Transients in Power Systems by Lou van der Sluis
- DigSilent power factory 15 download
- Training Attachments
- Software (if available)
Course details:
1: https://elec-engg.com/digsilent-training/
2: https://elec-engg.com/digsilent-training-advanced-level/
3: DIgSILENT
Abraham –
Helpful for me. thank u
Er. Fatima –
glad to hear that.our pleasure
Faisal abbass –
It’s very useful and knowledgeable
Carthy Claudius N. –
I am loving the course so far , thanks for the simplicity of the subject.
Cihangir A. –
so far I learn a lot and enjoy. Thanks Saeed.
Ashraful Islam –
Is the training on version 2022?
saeed –
no but some video attached to the training for the version 2022