The course covers 12 comprehensive modules:
- Introduction to Protection Relay Testing – Testing principles, primary and secondary injection, FAT, SAT, and commissioning workflow.
- Understanding the Protection System – CT/VT circuits, polarity, wiring diagrams, trip circuits, binary I/O, and DC systems.
- Secondary Injection Test Equipment – Omicron CMC hardware, current and voltage generation, connections, and configuration.
- Omicron Test Universe Practical Training – Test Object configuration, test modules, ramping, state sequencing, automation, and test reports.
- Overcurrent & Earth Fault Protection Testing – ANSI 50/51, 50N/51N, directional protection, pickup, timing, and inverse-time characteristics.
- Distance Protection Testing – Mho and quadrilateral characteristics, protection zones, fault testing, and practical Omicron applications.
- Transformer Differential & REF Testing – Differential characteristics, CT compensation, bias, inrush restraint, and REF testing.
- Generator & Motor Protection Testing – Differential, loss of excitation, reverse power, stator earth fault, negative sequence, and thermal protection.
- Busbar & Advanced Protection Testing – Busbar differential, zone selection, check zone, CT supervision, and breaker failure protection.
- Complete Protection System Commissioning – Relay-to-breaker trip chain, interlocking, end-to-end testing, and functional testing.
- Troubleshooting & Fault Analysis – Common testing mistakes, relay operation analysis, event records, and SIGRA waveform analysis.
- Real Commissioning Case Studies – Feeder, transformer, and line protection commissioning, test reports, and acceptance criteria.
Module 1 – Introduction to Protection Relay Testing
- Purpose of relay testing and commissioning
- Types of relay tests
- Primary vs secondary injection
- Factory acceptance test (FAT) and site acceptance test (SAT)
- Commissioning workflow
Module 2 – Understanding the Protection System
- CT and VT circuits
- CT polarity and ratio verification
- Protection wiring diagrams
- Trip and close circuits
- Binary inputs and outputs
- DC supply and auxiliary circuits
Module 3 – Secondary Injection Test Equipment
- Introduction to Omicron CMC
- Current and voltage generation
- Binary inputs and outputs
- Test leads and connection diagrams
- Safety considerations
- Test equipment configuration
Module 4 – Omicron Test Universe Practical Training
- Test Object configuration
- Hardware configuration
- Test plans and test modules
- Ramping and state sequencing
- Binary signal assignment
- Automatic test reports
- Test templates and reusable test plans
Module 5 – Overcurrent and Earth Fault Testing
- ANSI 50/51 and 50N/51N
- Pickup and dropout tests
- Definite-time testing
- Inverse-time characteristics
- Directional overcurrent testing
- Multiple-stage protection testing
Module 6 – Distance Protection Testing
- Impedance characteristics
- Mho and quadrilateral zones
- Zone reach and operating time
- Phase and earth fault testing
- Load encroachment
- Power swing considerations
- Practical Omicron distance testing
Module 7 – Transformer Differential and REF Testing
- Transformer differential protection
- CT ratio and vector group compensation
- Differential and restraint current
- Bias characteristic testing
- Inrush restraint
- REF stability and sensitivity
- Practical differential testing
Module 8 – Generator and Motor Protection Testing
- Generator differential protection
- Loss of excitation
- Reverse power
- Stator earth fault
- Negative sequence
- Motor overload and thermal protection
- Motor differential protection
Module 9 – Busbar and Advanced Protection Testing
- Busbar differential protection
- Zone selection
- Check zone
- CT supervision
- Breaker failure protection
- Interlocking and trip logic
Module 10 – Complete Protection System Commissioning
- Relay-to-breaker trip chain
- Trip circuit supervision
- Circuit breaker operation
- Intertrip and interlocking
- End-to-end testing
- Functional testing
- Commissioning checklists
Module 11 – Troubleshooting and Fault Analysis
- Common testing mistakes
- Unexpected relay operation
- Incorrect CT polarity
- Wrong relay settings
- Trip circuit failures
- Event and disturbance record analysis
- SIGRA and fault waveform analysis
Module 12 – Real Commissioning Case Studies
- Complete feeder commissioning
- Transformer protection commissioning
- Line protection commissioning
- Test report preparation
- Practical acceptance criteria
- Final commissioning documentation

Why Join This Masterclass?
- Practical, application-oriented training.
- Hands-on understanding of Omicron CMC and Test Universe.
- Coverage of different protection functions and relay applications.
- Real-world commissioning scenarios and case studies.
- From basic testing principles to advanced protection testing.
Training Delivery
Online training is available based on request.
