Relay Testing & Commissioning Masterclass

The course covers 12 comprehensive modules:

  1. Introduction to Protection Relay Testing – Testing principles, primary and secondary injection, FAT, SAT, and commissioning workflow.
  2. Understanding the Protection System – CT/VT circuits, polarity, wiring diagrams, trip circuits, binary I/O, and DC systems.
  3. Secondary Injection Test Equipment – Omicron CMC hardware, current and voltage generation, connections, and configuration.
  4. Omicron Test Universe Practical Training – Test Object configuration, test modules, ramping, state sequencing, automation, and test reports.
  5. Overcurrent & Earth Fault Protection Testing – ANSI 50/51, 50N/51N, directional protection, pickup, timing, and inverse-time characteristics.
  6. Distance Protection Testing – Mho and quadrilateral characteristics, protection zones, fault testing, and practical Omicron applications.
  7. Transformer Differential & REF Testing – Differential characteristics, CT compensation, bias, inrush restraint, and REF testing.
  8. Generator & Motor Protection Testing – Differential, loss of excitation, reverse power, stator earth fault, negative sequence, and thermal protection.
  9. Busbar & Advanced Protection Testing – Busbar differential, zone selection, check zone, CT supervision, and breaker failure protection.
  10. Complete Protection System Commissioning – Relay-to-breaker trip chain, interlocking, end-to-end testing, and functional testing.
  11. Troubleshooting & Fault Analysis – Common testing mistakes, relay operation analysis, event records, and SIGRA waveform analysis.
  12. Real Commissioning Case Studies – Feeder, transformer, and line protection commissioning, test reports, and acceptance criteria.

Module 1 – Introduction to Protection Relay Testing

  • Purpose of relay testing and commissioning
  • Types of relay tests
  • Primary vs secondary injection
  • Factory acceptance test (FAT) and site acceptance test (SAT)
  • Commissioning workflow

Module 2 – Understanding the Protection System

  • CT and VT circuits
  • CT polarity and ratio verification
  • Protection wiring diagrams
  • Trip and close circuits
  • Binary inputs and outputs
  • DC supply and auxiliary circuits

Module 3 – Secondary Injection Test Equipment

  • Introduction to Omicron CMC
  • Current and voltage generation
  • Binary inputs and outputs
  • Test leads and connection diagrams
  • Safety considerations
  • Test equipment configuration

Module 4 – Omicron Test Universe Practical Training

  • Test Object configuration
  • Hardware configuration
  • Test plans and test modules
  • Ramping and state sequencing
  • Binary signal assignment
  • Automatic test reports
  • Test templates and reusable test plans

Module 5 – Overcurrent and Earth Fault Testing

  • ANSI 50/51 and 50N/51N
  • Pickup and dropout tests
  • Definite-time testing
  • Inverse-time characteristics
  • Directional overcurrent testing
  • Multiple-stage protection testing

Module 6 – Distance Protection Testing

  • Impedance characteristics
  • Mho and quadrilateral zones
  • Zone reach and operating time
  • Phase and earth fault testing
  • Load encroachment
  • Power swing considerations
  • Practical Omicron distance testing

Module 7 – Transformer Differential and REF Testing

  • Transformer differential protection
  • CT ratio and vector group compensation
  • Differential and restraint current
  • Bias characteristic testing
  • Inrush restraint
  • REF stability and sensitivity
  • Practical differential testing

Module 8 – Generator and Motor Protection Testing

  • Generator differential protection
  • Loss of excitation
  • Reverse power
  • Stator earth fault
  • Negative sequence
  • Motor overload and thermal protection
  • Motor differential protection

Module 9 – Busbar and Advanced Protection Testing

  • Busbar differential protection
  • Zone selection
  • Check zone
  • CT supervision
  • Breaker failure protection
  • Interlocking and trip logic

Module 10 – Complete Protection System Commissioning

  • Relay-to-breaker trip chain
  • Trip circuit supervision
  • Circuit breaker operation
  • Intertrip and interlocking
  • End-to-end testing
  • Functional testing
  • Commissioning checklists

Module 11 – Troubleshooting and Fault Analysis

  • Common testing mistakes
  • Unexpected relay operation
  • Incorrect CT polarity
  • Wrong relay settings
  • Trip circuit failures
  • Event and disturbance record analysis
  • SIGRA and fault waveform analysis

Module 12 – Real Commissioning Case Studies

  • Complete feeder commissioning
  • Transformer protection commissioning
  • Line protection commissioning
  • Test report preparation
  • Practical acceptance criteria
  • Final commissioning documentation
OMICRON relay testing

Why Join This Masterclass?

  • Practical, application-oriented training.
  • Hands-on understanding of Omicron CMC and Test Universe.
  • Coverage of different protection functions and relay applications.
  • Real-world commissioning scenarios and case studies.
  • From basic testing principles to advanced protection testing.

Training Delivery

Online training is available based on request.