This course will start with installing software and start learning with practice!
Laptop with Windows platform
Daily Time Schedule:
- 9:00 – 10:30: Section A
- 10:30 – 10:45 Break
- 10:45 – 12:00: Section B
- 12:00 – 14:00 Lunch Break
- 14:00 – 15:30: Section C
- 15:30 – 15:45: Break
- 15:45 – 17: Section D
Day 1:
Section A: Introduction and SIPROTEC 5
- Substation Automation & Protection Structure
- Protection system elements
- Numerical Relays
- ANSI Codes
Section B: Practical section (Logs, and records)
- Install DIGSI 5 and SIGRA software
- Connect to relay with DIGSI 5 and without DIGSI 5
- Read logs and record from the relay
- Relay offline and online mode, assign relay
- Save / Export logs and records
- Fault Recording Parameters
- Config Logs and records
- Binary inputs and outputs configuration
- Binary inputs and output parameters
- Binary inputs, binary outputs, and LED test
Section C: Measurement and Analog Input
- CT and PT connections
- Measuring point configuration
- Measuring point parameters
- Test Suits and Test Sequence
- Execute test sequences
- Monitor Operational values in the relay
- Monitor Fundamental Component in the relay
- Monitor breaker information
Section D: Overcurrent config and test
- Overcurrent phase
- Overcurrent ground
- OC config
- OC parameters
- OC testing
- OC fault log
- OC fault record
- Overcurrent RIO block
Day 2
Section A: SIGRA and Fault Analysis
- Power system faults
- Simulate faults
- SIGRA
- Harmonics
Section B: Current protection
- Single-phase OC
- Negative sequence protection
- Overload protection
Section C: Voltage & Directional Protection
- Over/under Voltage protection
- Over/under Fequency protection
- Directional OC
- Directional Earth Fault
- Directional OC Testing
Section D: Application Templates and PSLD
- 7UT Application Templates
- 7SA Application Templates
- 7UM Application Templates
- Protection Single Line Diagram
Day 3
Section A and B: 7UT8 config, parameters, and Testing
- Transformer Protection
- Diff principal
- Diff config
- Diff parameters
- Differential RIO block
- Diff testing
- Case study relay config
Section C and D: 7SA8 config, parameters, and Testing
- Line protection
- Distance protection
- Tele-protection
- STUB protection
- Distance RIO block
Day 4:
Section A and B: 7SS8 config and parameters
- Busbar protection
- Centralized BB protection
- Sample Centralized BB Config
- Distributed BB protection
- Case Study 7SS85 Config
Section C and D: 7VK8 config and parameters
- Circuit breaker failure
- Auto Recloser
Day 5:
Section A: 7SD and 7SL config and parameters
- Line Differential
Section B, C, and D: 7UM Config and Parameters
- Generator Protection
- Motor protection
Leave a comment on this post or contact us if you want to join this training