CYMCAP Software Installation, Configuration & Technical Support

Are you looking for CYMCAP software installation and configuration support?

CYMCAP – Power Cable Ampacity Calculation and Thermal Analysis Software

Elec-Engg provides technical assistance for installing and configuring CYMCAP, a specialized engineering software developed by Eaton (CYME International) for power cable ampacity calculations, thermal analysis, and electrical cable system design.

CYMCAP is widely used by power cable manufacturers, electrical utilities, engineering consultants, transmission and distribution companies, and industrial electrical engineers.

The software helps engineers calculate the current-carrying capacity (ampacity) of power cables under different installation and environmental conditions. It also provides detailed thermal analysis to evaluate cable operating temperatures, heat dissipation, and the impact of different loading conditions.

Whether you are designing underground cable installations, evaluating existing cable systems, planning cable routes, or investigating cable overheating problems, CYMCAP provides specialized calculation tools for power cable engineering.

What Is CYMCAP Software?

CYMCAP (Power Cable Ampacity Software) is an advanced engineering application designed for calculating the ampacity and temperature rise of power cable installations.

It allows engineers to model different cable constructions, installation arrangements, soil conditions, and electrical loading scenarios.

The software uses established analytical techniques, including Neher-McGrath and IEC calculation methods, to evaluate the thermal performance of power cables.

CYMCAP is particularly useful for:

  • Underground power cable design
  • Cable ampacity calculations
  • Cable thermal analysis
  • Cable sizing and rating
  • Cable installation optimization
  • Cable temperature calculations
  • Cyclic and emergency loading studies
  • Cable system performance assessment
  • High-voltage and extra-high-voltage cable engineering
  • Submarine cable installation studies

Main Applications and Features of CYMCAP

1. Power Cable Ampacity Calculation

Ampacity is the maximum current a power cable can carry continuously or under specified operating conditions without exceeding its permissible temperature limits.

Accurate cable ampacity calculations are essential for selecting suitable cables and ensuring reliable electrical system operation.

CYMCAP allows engineers to calculate:

  • Continuous current-carrying capacity
  • Cable ampacity under different installation conditions
  • Maximum permissible cable loading
  • Cable conductor temperature
  • Cable thermal resistance
  • Cable thermal losses
  • Cable loading limitations
  • Cable rating under different soil conditions

The software supports different cable configurations and installation arrangements.

2. Cable Thermal Analysis

Cable thermal analysis is essential for understanding the temperature behaviour of electrical cables under different loading conditions.

CYMCAP calculates the temperature distribution and heat dissipation within cable installations.

Typical applications include:

  • Conductor temperature calculations
  • Cable insulation temperature assessment
  • Cable sheath temperature calculations
  • Armour temperature assessment
  • Thermal resistance calculations
  • Heat dissipation analysis
  • Mutual heating between adjacent cables
  • Soil temperature distribution
  • Cable thermal performance assessment

These calculations help engineers identify potential overheating problems and optimize cable installations.

3. Cable Construction and Modelling

CYMCAP provides detailed modelling capabilities for different power cable constructions.

Engineers can define cable dimensions, materials, electrical properties, and thermal characteristics.

Supported cable constructions include:

  • Single-core power cables
  • Three-core power cables
  • Belted cables
  • Pipe-type cables
  • Armoured cables
  • Sheathed cables
  • Submarine cables
  • HVDC cables
  • Cables with different metallic and non-metallic layers

Cable construction parameters can include conductor material, insulation, metallic sheath, armour, outer serving, and additional cable layers.

The software also provides cable libraries to simplify the modelling process.

4. Underground Cable Installation Modelling

Different installation conditions significantly influence the current-carrying capacity of power cables.

CYMCAP supports modelling of various cable installation configurations, including:

  • Direct buried cables
  • Underground ducts
  • Duct banks
  • Thermal backfill installations
  • Cables installed in air
  • Cable groups on trays
  • Cable installations in tunnels
  • Cable installations in troughs
  • Cables in protective casings
  • Submarine cable installations

Engineers can investigate the thermal interaction between multiple cables and surrounding installation materials.

5. Soil Thermal Resistivity Analysis

Soil thermal resistivity is an important parameter in underground cable ampacity calculations.

The thermal properties of surrounding soil influence how effectively heat generated by cable losses is dissipated.

CYMCAP allows engineers to consider:

  • Soil thermal resistivity
  • Backfill thermal resistivity
  • Different soil layers
  • Soil temperature conditions
  • Soil moisture migration
  • Soil dry-out effects
  • Thermal interaction between cable circuits

Accurate soil thermal modelling is particularly important for underground transmission and distribution cable projects.

6. Cyclic Loading and Emergency Rating

Power cables do not always operate at constant loading conditions.

In many electrical networks, cable loading changes throughout the day depending on electricity demand and generation.

CYMCAP supports cyclic loading and transient thermal analysis to investigate cable behaviour under changing load profiles.

Applications include:

  • Daily cyclic loading
  • Weekly and yearly load profiles
  • Emergency cable loading
  • Short-term overload assessment
  • Cable temperature versus time
  • Ampacity versus time
  • Time required to reach maximum permissible temperature
  • Transient thermal response

These calculations help engineers evaluate the available thermal capacity of existing cable installations.

7. Cable Sheath Bonding and Loss Calculations

Metallic cable sheaths and armour systems can experience induced voltages and circulating currents.

These effects influence cable losses and consequently affect cable ampacity.

CYMCAP supports modelling different sheath bonding arrangements, including:

  • Solid bonding
  • Single-point bonding
  • Cross-bonding
  • Cable sheath circulating current calculations
  • Eddy current losses
  • Metallic sheath losses
  • Armour losses
  • Cable electrical interactions

Correct modelling of sheath bonding is especially important for high-voltage single-core cable installations.

8. Cable Impedance and Electrical Parameters

In addition to thermal calculations, CYMCAP offers optional functionality for calculating electrical parameters of cable installations.

Applications include:

  • Positive-sequence impedance
  • Zero-sequence impedance
  • Cable resistance
  • Cable reactance
  • Cable admittance
  • Cable inductance
  • Cable capacitance
  • Electrical parameter assessment for different installation arrangements

These parameters are useful for power system studies and electrical network modelling.

9. Magnetic Field Analysis

CYMCAP provides an optional Magnetic Fields module for evaluating magnetic fields generated by underground cable installations.

Applications include:

  • Magnetic flux density calculations
  • Magnetic field distribution
  • Magnetic field assessment above buried cables
  • Magnetic field analysis around cable routes
  • Evaluation of different cable arrangements
  • Magnetic field reduction through installation optimization

This functionality is useful when investigating electromagnetic field levels around underground power cable systems.

10. Short Circuit Cable Rating

Cable systems must be capable of withstanding the thermal effects of short circuit currents for the specified protection clearing time.

CYMCAP offers an optional Short Circuit Rating module for investigating cable short circuit withstand capability.

Applications include:

  • Short circuit thermal rating
  • Conductor temperature during faults
  • Cable short circuit withstand assessment
  • Maximum permissible fault duration
  • Cable conductor sizing verification

These calculations help engineers evaluate whether cable conductors are suitable for the expected fault current and clearing time.

11. Cable Crossings and 3D Modelling

Complex underground cable routes may include multiple circuits crossing each other, changing depth, and following different installation geometries.

CYMCAP offers specialized capabilities for modelling complex cable arrangements.

The optional 3D Modeling module supports:

  • Three-dimensional cable route modelling
  • Cable crossings
  • Different cable installation depths
  • Cable route direction changes
  • Complex underground arrangements
  • Thermal interactions between crossing circuits
  • Temperature calculations for complex cable geometries

This is particularly useful for congested underground cable corridors and large infrastructure projects.

CYMCAP Software Modules

CYMCAP includes a base package and additional modules that extend its analytical capabilities.

Some important optional modules include:

ModuleMain application
Base PackageCable ampacity and thermal calculations
Duct Bank OptimizerOptimization of cable placement within duct banks
Magnetic FieldsMagnetic field calculations
Cables CrossingsThermal analysis of crossing circuits
Multiple CasingsCable installations in multiple casings
Cables in TunnelsThermal rating of tunnel installations
Multiple Duct BanksModelling multiple duct banks and backfills
Short Circuit RatingCable short circuit thermal assessment
3D ModelingComplex three-dimensional cable arrangements
Cable Impedance CalculationElectrical cable parameter calculations
Soil Dry-Out AnalysisSoil dry-out and thermal limitations
Submarine Cable InstallationsSubmarine cable thermal rating
Cables in TroughsThermal analysis of cables in trough installations
Parametric StudiesSensitivity and optimization studies

The availability of these functions depends on the CYMCAP package and licensed add-on modules.

International Standards Used in CYMCAP Calculations

CYMCAP supports cable thermal calculations based on recognized international engineering methods and standards.

Important references include:

  • IEC 60287 – Electric cables: Calculation of the current rating
  • IEC 60853 – Calculation of the cyclic and emergency current rating of cables
  • IEC 60228 – Conductors of insulated cables
  • Neher-McGrath method – Cable ampacity and thermal calculations
  • Applicable CIGRE technical recommendations

The selected calculation method and applicable standard depend on the cable type, installation configuration, and engineering requirements.

CYMCAP, CYMCAP Software, CYMCAP Installation, CYMCAP Software Installation, CYMCAP Configuration, CYMCAP Training, Power Cable Ampacity, Cable Ampacity Calculation, Cable Thermal Analysis, Underground Cable Design, Power Cable Engineering, Cable Sizing, Cable Rating, IEC 60287, IEC 60853, Neher McGrath, Cable Sheath Losses, Cable Impedance Calculation, Cable Short Circuit Rating, Cable Installation Design, High Voltage Cables, Underground Power Cables, Electrical Engineering Software, Power System Engineering

CYMCAP Software Installation and Configuration Support

Elec-Engg provides technical assistance for CYMCAP software installation and initial configuration.

Our objective is to help electrical engineers prepare their computer environment for performing power cable ampacity calculations and thermal analysis.

Who Should Use CYMCAP?

CYMCAP is particularly useful for professionals working in:

  • Underground power cable engineering
  • High-voltage cable design
  • Extra-high-voltage transmission projects
  • Electrical distribution networks
  • Substation cable engineering
  • Industrial electrical installations
  • Power cable manufacturing
  • Cable installation and commissioning
  • Electrical engineering consultancy
  • Renewable energy and offshore projects

It is also a valuable engineering tool for electrical engineering students, researchers, and postgraduate engineers working on power cable design and thermal analysis.

Learn Electrical Engineering with Elec-Engg

Elec-Engg provides practical technical training in power system protection, substation automation, and electrical engineering software.

Our training approach focuses on practical engineering applications, software demonstrations, and real-world electrical engineering problems.

Need CYMCAP Software Installation Support?

Contact Elec-Engg to discuss your software version, computer requirements, and installation assistance.

Frequently Asked Questions (FAQ)

1. What is CYMCAP software used for?

CYMCAP is used for power cable ampacity calculations, cable thermal analysis, cable temperature assessment, and underground cable installation design.

2. What does ampacity mean?

Ampacity is the maximum current a cable can carry under specified operating and environmental conditions without exceeding its permissible temperature limits.

3. Can CYMCAP calculate underground cable ampacity?

Yes. CYMCAP supports different underground cable installation arrangements, including direct burial, underground ducts, duct banks, and thermal backfill.

4. Can CYMCAP perform cable thermal analysis?

Yes. It calculates cable temperature, thermal resistance, heat losses, and thermal interactions between cables and their surrounding environment.

5. Does CYMCAP support IEC 60287 calculations?

Yes. CYMCAP supports cable rating calculations based on IEC 60287 and other recognized methods.

6. Can CYMCAP analyse cyclic cable loading?

Yes. CYMCAP supports cyclic loading and transient thermal calculations using defined load profiles.

7. Can CYMCAP calculate cable sheath losses?

Yes. It supports detailed loss calculations, including sheath circulating current losses, eddy current losses, and other relevant cable losses.

8. Can CYMCAP calculate cable impedance?

Yes. The optional Cable Impedance Calculation module supports the calculation of electrical cable parameters.

9. Can CYMCAP perform short circuit cable rating calculations?

Yes. The optional Short Circuit Rating module supports the thermal assessment of cable conductors under short circuit conditions.

For further information, contact Elec-Engg.