7SS85 Busbar Protection Training

(Created: April 2024) (Last update: 2024)

Training for the SIPROTEC 5 7SS8 busbar protection system involves understanding the features and capabilities of the SIPROTEC 5 series, specifically focusing on the SIPROTEC 5 7SS8 device used for busbar protection. This training outline ensures a comprehensive understanding of the SIPROTEC 5 7SS8 busbar protection system, combining theoretical knowledge with practical skills to enhance the proficiency of participants in using and maintaining the system.

  • Face-to-face / Online Course based on the request
  • Trainer: Dr. Saeed Roostaee (Profile)
  • Collecting feedback from participants to improve future training sessions

Prerequisite:

Course Details:

  • Introduction to Busbar Protection
  • Overview of busbars in power distribution and the necessity of protection.
  • Short circuits, phase-to-phase faults, earth faults, and their impacts.
  • Fundamentals of Busbar Protection
  • Overcurrent protection, differential protection, and distance protection.
  • How to define and the significance of protection zones in busbar protection.
  • Overview of SIPROTEC 5 Series
  • Introduction to the SIPROTEC 5 series and its application in power system protection.
  • Flexibility, modularity, communication capabilities, and advanced protection functions.
  • Introduction to SIPROTEC 5 7SS8 Busbar Protection
  • Detailed introduction to the 7SS8 device, its components, and functionality.
  • High-speed tripping, selective tripping, fault location, and advanced monitoring.
  • Components of the SIPROTEC 5 7SS8 System
  • Detailed explanation of various relays and modules in the 7SS8 system.
  • Role, types, and correct placement of CTs for busbar protection.
  • Importance and configuration of communication interfaces for relay coordination and data exchange.
  • Configuration and Setting of the 7SS8 System
  • Steps to configure the 7SS8 system for different busbar arrangements.
  • Detailed guide on setting parameters such as sensitivity, time delays, and operating modes.
  • Methods to test and validate the configuration and settings.
  • Operation and Maintenance of the SIPROTEC 5 7SS8 System
  • Understanding the operation of the SIPROTEC 5 7SS8 system under normal conditions.
  • Response of the SIPROTEC 5 7SS8 system to various fault conditions and analysis of fault records.
  • Routine maintenance tasks to ensure system reliability and performance.
  • Troubleshooting and Fault Analysis
  • Identification and resolution of common issues in busbar protection using the 7SS8.
  • Methods to analyze and diagnose faults using SIPROTEC 5 7SS8 logs and data.
  • Practical Training
  • Reference documents for further reading and in-depth understanding.
  • Practical sessions on configuring the SIPROTEC 5 7SS8 system using DIGSI 5 software.
  • Simulating different fault scenarios and observing the system’s response.
  • Analyzing real-world case studies involving the 7SS8 busbar protection system.
  • Providing comprehensive manuals and guides on the SIPROTEC 5 7SS8 system.
  • Introduction to DIGSI 5 and other software tools used for configuring and monitoring the SIPROTEC 5 7SS8 system.
7SS85 hardware (7SS85 centralized Busbar protection relay)
7SS85 hardware (7SS85 distributed busbar)
7SS85 online configurator for ordering the relay
7SS85 centralized busbar protection relay config in digsi 5
how to test a centralized SIPROTEC 5 busbar configuration with SIPROTEC DigitalTwin
7SS85 distributed busbar protection relay config in digsi 5
IEC 61850 configuration in the 7SS85 distributed busbar protection

7SS85 Busbar protection

    Leave a Comment

    Your email address will not be published. Required fields are marked *

    Scroll to Top