(Created: April 2024) (Last update: 2024)
Training for the SIPROTEC 5 7SS8 busbar protection system involves understanding the features and capabilities of the SIPROTEC 5 series, specifically focusing on the SIPROTEC 5 7SS8 device used for busbar protection. This training outline ensures a comprehensive understanding of the SIPROTEC 5 7SS8 busbar protection system, combining theoretical knowledge with practical skills to enhance the proficiency of participants in using and maintaining the system.
- Face-to-face / Online Course based on the request
- Trainer: Dr. Saeed Roostaee (Profile)
- Collecting feedback from participants to improve future training sessions
Prerequisite:
Course Details:
- Introduction to Busbar Protection
- Overview of busbars in power distribution and the necessity of protection.
- Short circuits, phase-to-phase faults, earth faults, and their impacts.
- Fundamentals of Busbar Protection
- Overcurrent protection, differential protection, and distance protection.
- How to define and the significance of protection zones in busbar protection.
- Overview of SIPROTEC 5 Series
- Introduction to the SIPROTEC 5 series and its application in power system protection.
- Flexibility, modularity, communication capabilities, and advanced protection functions.
- Introduction to SIPROTEC 5 7SS8 Busbar Protection
- Detailed introduction to the 7SS8 device, its components, and functionality.
- High-speed tripping, selective tripping, fault location, and advanced monitoring.
- Components of the SIPROTEC 5 7SS8 System
- Detailed explanation of various relays and modules in the 7SS8 system.
- Role, types, and correct placement of CTs for busbar protection.
- Importance and configuration of communication interfaces for relay coordination and data exchange.
- Configuration and Setting of the 7SS8 System
- Steps to configure the 7SS8 system for different busbar arrangements.
- Detailed guide on setting parameters such as sensitivity, time delays, and operating modes.
- Methods to test and validate the configuration and settings.
- Operation and Maintenance of the SIPROTEC 5 7SS8 System
- Understanding the operation of the SIPROTEC 5 7SS8 system under normal conditions.
- Response of the SIPROTEC 5 7SS8 system to various fault conditions and analysis of fault records.
- Routine maintenance tasks to ensure system reliability and performance.
- Troubleshooting and Fault Analysis
- Identification and resolution of common issues in busbar protection using the 7SS8.
- Methods to analyze and diagnose faults using SIPROTEC 5 7SS8 logs and data.
- Practical Training
- Reference documents for further reading and in-depth understanding.
- Practical sessions on configuring the SIPROTEC 5 7SS8 system using DIGSI 5 software.
- Simulating different fault scenarios and observing the system’s response.
- Analyzing real-world case studies involving the 7SS8 busbar protection system.
- Providing comprehensive manuals and guides on the SIPROTEC 5 7SS8 system.
- Introduction to DIGSI 5 and other software tools used for configuring and monitoring the SIPROTEC 5 7SS8 system.
7SS85 Busbar protection