Information
- Course Name: SIPROTEC 5 and DIGSI 5 (advanced)
- Trainer: Dr. Saeed Roostaee
- Format: Pre-recorded videos (demo is available)
- Course creation: June 2023
- Last update: July 2023
Note: This course can also be held either Online or Face to face based on the request
Course Structure:
- Module 1: SIPROTEC 5 Hardware and ordering
- Module 2: Starting with DIGSI 5
- Module 3: Working with SIPROTEC 5 in online mode
- Module 4: System Functions
- Module 5: Function Groups
- Module 6: SIPROTEC 7SJ8
- Module 7: SIPROTEC 7SA8
- Module 8: SIPROTEC 7UT8
- Module 9: SIPROTEC 7SS8
- Module 10: SIPROTEC 7SK8
- Module 11: SIPROTEC 7VK8
- Module 12: SIPROTEC 7SD8
- Module 13: SIPROTEC 7SL8
- Module 14: SIPROTEC 7SX8
- Module 15: SIPROTEC 7UM8
- Module 16: SIPROTEC 7MD8
- Module 17: Functions and Settings
- Module 18: Signals and Masking IO
- Module 19: CFC
- Module 20: Control Functions
- Module 21: Display Page configuration
- Module 22: Functional Tests
- Module 23: Measured Values
- Module 24: Power Quality
- Module 25: Supervision
- Module 26: Communication
- Module 27: IEC 61850
- Module 28: Digital Twin
- Module 29: Case Study 7UT8
- Module 30: Case Study 7VK8
- Module 31: Case Study 7SA8
- Module 32: Case Study 7SS8
Course Details (Note: This part is continuously updating)
Module: SIPROTEC 5 Hardware and order
- SIPROTEC5 Hardware
- DIGSI 5 installation and DDD
- General Settings
- DIGSI 5 User interface
- New project + Add device (Offline)
- Modify the order code in the SIPROTEC online configurator
- SIPROTEC 5 Online Configurator
- Function Point
- SIP 5 Configuration Procedure
Module: Online & Working with SIPROTEC 5
- Connect to SIPROTEC 5
- Indications
- Fault Recording
- Log
- Reading Indications on the On-Site Operation Panel
- Reading Indications from the PC with DIGSI 5
- Displaying Indications
- Operational Log
- Fault Log
- Switching-Device Log
- Ground-Fault Log
- Setting-History Log
- User Log
- Security Log
- Device-Diagnosis Log
- Communication Log
- Communication-Supervision Log
- Motor-Starting Log
- Saving and Deleting the Logs
- Spontaneous Indication Display in DIGSI 5
- Spontaneous Fault Display on the On-Site Operation Panel
- Stored Indications in the SIPROTEC 5 Device
- Resetting Stored Indications of the Function Group
- Test Mode and Influence of Indications on Substation Automation Technology
- Changing the Transformation Ratios of the Transformer on the Device
Module: System Functions
- Sampling-Frequency Tracking and Frequency Tracking Groups
- Text Structure and Reference Number for Settings and Indications
- Processing Quality Attributes
- Protection Communication
- Date and Time Synchronization
- User-Defined Objects
- Device Settings
- Data Types
- Function Control
- Connection Examples
- Chatter blocking
- Settings-Group Switching
Module: Function Groups
- Voltage current 3-Phase
- Circuit-breaker
- Process Monitor
- Voltage-current 1-phase
- Motor
- Line
- Voltage 3-Phase
- Analog Units
- User-Defined Function Group
- Recording
- Motor Monitor
- Current-Flow Criterion
- Circuit-Breaker Condition for the Motor
- Closure Detection
- Motor-State Detection
- Cold-Load Pickup Detection
- Thermal Replica Rotor
- Capacitor Bank
Module: Functions and Settings
- Power-System Data
- Overcurrent Protection, Phases
- Overcurrent Protection, Ground
- Line Differential Protection
- Stub Differential Protection
- Restricted Ground-Fault Protection
- Distance Protection with Reactance Method (RMD)
- Distance Protection with Classic Method
- Impedance Protection
- Power-Swing Blocking
- Teleprotection with Distance Protection
- Universal Teleprotection with Distance Protection
- Ground-Fault Protection for High-Resistance Ground Faults in Grounded Systems
- Teleprotection with Ground-Fault Protection
- Universal Teleprotection with Ground-Fault Protection
- Echo and Tripping in the Event of Weak Infeed 874
- Tripping with Missing or Weak Infeed According to French Specification
- External Trip Initiation
- Automatic Reclosing Function
- Directional Overcurrent Protection, Phases
- Positive-Sequence Overcurrent Protection
- Instantaneous High-Current Tripping
- Group Indications of Overcurrent Protection Functions
- Overcurrent Protection, 1-Phase
- Voltage-Dependent Overcurrent Protection, Phases
- Sensitive Ground-Fault Detection
- Non-Directional Intermittent Ground-Fault Protection
- Directional Intermittent Ground-Fault Protection
- Negative-Sequence Protection
- Directional Negative-Sequence Protection with Current-Independent Time Delay
- Undercurrent Protection
- Overvoltage Protection with 3-Phase Voltage
- Overvoltage Protection with Positive-Sequence Voltage
- Overvoltage Protection with Negative-Sequence Voltage
- Overvoltage Protection with Positive-Sequence Voltage and Compounding
- Overvoltage Protection with Zero-Sequence Voltage/Residual Voltage
- Overvoltage Protection with Any Voltage
- Undervoltage Protection with 3-Phase Voltage
- Undervoltage Protection with Positive-Sequence Voltage
- Undervoltage Protection with Any Voltage
- Rate-of-Voltage-Change Protection
- Undervoltage-Controlled Reactive-Power Protection
- Voltage-Comparison Supervision
- Fault Locator
- Fault Locator Plus
- Over frequency Protection
- Under frequency Protection
- Rate of Frequency Change Protection
- Under frequency Load Shedding
- Phase-Sequence Switchover
- Instantaneous Tripping at Switch onto Fault
- Thermal Overload Protection, 3-Phase – Advanced
- Thermal Overload Protection, 1-Phase
- Temperature Supervision
- Circuit-Breaker Failure Protection
- Circuit-Breaker Restrike Protection
- Out-of-Step Protection
- Inrush-Current and 2nd Harmonic Detection
- Power Protection (P, Q), 3-Phase
- Current-Jump Detection
- Voltage-Jump Detection
- Vector-Jump Protection
- Arc Protection
- Voltage Measuring-Point Selection
Module: Specific Functions
- Current-Unbalance Protection for Capacitors, 1-Phase
- Peak Overvoltage Protection for Capacitors
- Motor-Starting Time Supervision
- Motor Restart Inhibit
- Load-Jam Protection Motor
- Thermal Overload Protection, Rotor
Module: Control Functions
- Introduction
- Switching Devices
- Switching Sequences
- Control Functionality
- Synchronization Function
- User-Defined Function Block [Control]
- CFC-Chart Settings
- Tap Changers
- Voltage Controller
- Point-on-Wave Switch
Module: Functional Tests
- Direction Test of the Phase Quantities
- Functional Test Protection Communication
- Functional Test of the Line Differential Protection
- Functional Test for Overvoltage Protection with Zero-Sequence Voltage/Displacement Voltage
- Primary and Secondary Tests of the Circuit-Breaker Failure Protection
- Circuit-Breaker Test
- Out-of-Step Protection Function Test
- Functional Test of the Inrush-Current Detection
- Functional Test of the Trip-Circuit Supervision
- Power-Swing Blocking Functional Test
- Functional Test for the Phase-Rotation Reversal
- Functional Test for Overvoltage Protection with Zero-Sequence Voltage/Residual Voltage
- Directional Testing for Isolated or Resonant-Grounded Systems
- Primary and Secondary Testing of the Synchronization Function
- Commissioning Hints for Voltage Control
Module: Measured Values
- Operational Measured Values
- Fundamental and Symmetrical Components
- THD and Harmonics
- Minimum/Maximum Values
- Average Values
- Energy Values
- Circuit-Breaker Monitoring
- Statistical Values of the Primary System
Module: Power Quality
- Voltage Variation
- Voltage Unbalance
- THD and Harmonics
- Total Demand Distortion
Module: Supervision
- Resource-Consumption Supervision
- Supervision of the Secondary System
- Supervision of the Device Hardware
- Supervision of Device Firmware
- Supervision of Hardware Configuration
- Supervision of Communication Connections
- Error Responses and Corrective Measures
- Group Indications
Module: IEC 61850
- External Signals
- Quality Processing/Affected by the User for Received GOOSE Values
- Quality Processing/Affected by the User in CFC Charts
- Quality Processing/Affected by the User in Internal Device Functions
More info and update about this course: Contac us
what is the fee for this course sir
This course is online and F2f
please text us on whatsapp: +989129613659 to get more info