29 – 31 January 2026
Prerequisites:
- Power System Protection for Beginners
- SIPROTEC 5 7UT Training
- Line protection with SIPROTEC 7SA8
- DIGSI 5 Training
- IEC 61850 Training
- 7SS85 Busbar Protection Training
- T&C Training
When everyone starts around the same level, the class can learn together more smoothly. So, please complete all prerequisite training packages to be eligible for enrollment in this online training.
COURSE CONTENT
INTRODUCTION TO POWER SYSTEM PROTECTION
Importance of this training
References
HV equipment
Power System components
Protection Single Line Diagram (PSLD)
Protection Panel
TCS Relay
Trip Relay
Lockout Relay
What do we want to protect?
Protection system elements
How does the protection system work?
-
INTRODUCTION TO NUMERICAL RELAY IEDS
Structure of Numerical Relay
Architecture of the Numerical Relay Multifunction Protection Relays
Example: Feeder Protection
Block diagram for typical numerical relays
Digital Phasor Measurement
Numerical Relay Calculations - Properties of SIPROTEC 5
SIPROTEC 5 expansion modules
Modular device concept, freely configurable
Devices without Jumpers- no more opening of the device
Sampling rate up to 16 kHz
Draw out of the terminal blocks
On-Site operation panel
IEC61850 Certification
START WITH DIGSI 5
- HARDWARE CONNECTIONS
Power supply connections - Current Transformer Terminals
4 protection-class current transformers
3 protection-class current transformers + 1 sensitive protection- class transformer
4 instrument transformers.
Connection Diagrams
3 Phase + IN
3 Phase
3 Phase + IN separate
Set test sequence & Monitor Current signals
Phase sequence
Neutral point in dir. Of object
Inverted phases
Connection Examples of Voltage Transformers
3-phase to ground voltages
3-phase to ground volt. + VN
2 ph-ph volt.
2 ph-ph volt. +VN
- RELAY MEASUREMENTS
Operational Measured Values
Fundamental Components
Symmetrical Components
Inject the three-phase values into the relay and monitor the relay measurements
Monitor relay phasor values
Relay binary inputs/outputs test
Operational value in the relay
Check phasor values in the relay
WORKING ONLINE WITH THE RELAY - Assign an online device to the project
Copy the online device to the project
Change Device mode
SIPROTEC 5 Web browser
Set date and time
Monitor binary inputs, outputs, and LEDs
Change parameters in the relays
Reading Indications from the PC
Operational Log
Fault Log
Ground-Fault Log
Fault Recording
Fault recorder settings
Fault recorder config
Download fault records
Commissioning mode
Binary Input and Output Test
- FAULTS
- Normal Operation of Power System
Abnormal Condition of power system
Types of faults
The cause of the fault in the power system equipment
Short circuit type fault
Short circuit with impedance
Broken conductor fault
Inter-circuit fault
Cross-country fault
Faults in overhead transmission lines
Generator Stator Winding Faults
Generator Rotor Circuit Faults
Transformer faults
Motor Thermal Failure
Failure rate of power system equipment - FAULT SIMULATIONS
- Single-phase fault simulation
Earth fault simulation
Phase-to-phase fault simulation
RMS and Instantaneous signals
Ph-Ph-E fault simulation
3-phase fault simulation
3-phase-E fault simulation
Fault Zero sequence values
Fault Negative sequence values
Fault impedance values
Primary and secondary values
-
OVERCURRENT DEFINITE TIME ANSI 50
Overcurrent DT 50
How to configure OC protection
How to test OC protection
OVERCURRENT INVERSE TIME ANSI 51
How OC relay works
Overcurrent IT 51
Overcurrent curves
How to configure OC protection
How to test OC protection - EARTH FAULT PROTECTION
IE calculation
IE measurements
Config earth fault protection
Earth log config in DIGSI 5 - TEST EARTH FAULT PROTECTION FUNCTION
Earth fault protection (ANSI 50N/51N)
Set test sequence
Inject earth fault values into the relay
Monitor the IE in the relay
CT Connection Types
Monitor earth fault current in the SIPROTEC 5 relays with different CT Connection types
Simulate several earth faults and test the function in the relay - NEGATIVE SEQUENCE CONFIG
Negative sequence protection function (ANSI 46)
Config Neg Seq protection in SIPROEC 5
Fault simulation and set test sequences
Inject the values and monitor the Negative sequence signals
Analyze relay logs and recorders
VOLTAGE PROTECTION
Over/ under voltage protection function (ANSI 27/59)
Config Overvoltage and under voltage
Set test sequences
Voltage protection testing
Analyze fault logs and recorders - DIRECTIONAL OVERCURRENT PROTECTION
Why Directional overcurrent protection
How to configure Directional overcurrent protection ANSI 67 in SIPROTEC 5
Simulate a fault in the forward direction
Simulate a fault in the backward direction
Create test sequences to test Direction OC Protection
Playback the signals and monitor the 67 function signals
Check relay fault logs and records - 67N DIR. OVERCURRENT PROTECTION GROUND
Why 67N?
How does 67N work?
How to configure 67N?
Fault simulation to test 67N
Create test sequences to test 67N
Test 67N with simulated signals
Analyze relay fault logs with 67N operation
Analyze the fault record with the 67N operation
- OVER EXCITATION PROTECTION
- Why overexcitation protection
- How to config over excitation protection in DIGSI5
- Set test sequences to test the overexcitation protection
- Check the relay fault logs for the overexcitation protection
- FREQUENCY PROTECTION
- Why frequency protection
- How to configure frequency protection functions
- Set test sequences to test frequency protection functions
- Test the frequency protection function
- Check the relay logs and records for the frequency protection signals
- COMTRADE VIEWER (SIGRA OR OTHER TOOLS)
- Comtrade format
- Import and configure the fault record in SIGRA
- Time signals
- Harmonic signals
- Binary signals
- RMS and Instantaneous values
- RELAY CONFIGURATION
- SIPROTEC 5 config procedure
- Application templates
- 7SJ8 Application Template
- 7UM8 Application Template
- 7UT8 Application Template
- 7SA8 Application Template
- Export template
- TRANSFORMER PROTECTION
- Why Transformer Protection
- Earth Fault on H.V. External Connections
- Phase-to-Phase Fault on H.V. External Connections, Internal Earth Fault on H.V. Windings
- Internal Phase-to-Phase Fault on H.V. Windings Short Circuit Between Turns H.V. Windings
- Earth Fault on L.V. External Connections
- Phase-to-Phase Fault on L.V. External Connection,s Internal Earth Fault on L.V. Windings
- Internal Phase-to-Phase Fault on L.V. Windings Short Circuit Between Turns L.V. Windings
- Transformer Protection Scheme
- TRANSFORMER DIFFERENTIAL PROTECTION
- Transformer Differential Protection
- Config Transformer Differential Protection in DIGSI 5
- Differential protection basics
- Restraint Differential protection
- Internal fault
- Internal fault (high-set element)
- Magnetizing current and blocking by the 2nd harmonic
- External faults
- External faults with CT saturation
- Differential protection config in SIPROTEC 5 7UT
- TRANSFORMER-RESTRICTED EARTH FAULT
- Why Restricted Earth Fault (ANSI 87N)?
- How does REF work?
- How to configure Transformer-REF
- In-zone and out-of-zone faults
- LINE PROTECTION
- Transmission Line Faults
Line protection functions
Why Use Distance Protection?
How Distance protection works
Distance Protection
Distance measurement (principle)
phase- phase -loop
phase- ground -loop
Load and short-circuit impedances
Distance characteristics
Stepped Distance protection - DISTANCE PROTECTION IN SIPROTEC 7SA8
General
Pickup method
Distance zones (quadrilateral characteristic curve preconfigured)
1-pole/3-pole output logic
Ground-fault detection
Direction Determination
BUSBAR PROTECTION
Busbar Protection Introduction
Busbar Differential Protection
Install the 7SS85 device driver
Config single Busbar arrangement in DIGSI 5
Config 1.5 busbar arrangement in DIGSI 5
Disconnector image
Config double busbar arrangement in DIGSI 5
29 – 31 January 2026