Skip to main content
  • Trainer: Dr. Saeed Roostaee (Profile)
  • Pre-recorded videos
  • The demo is available based on the request
  • Course creation 14 April 2022
  • Last update: 18 June 2023
  • Total hours: 2 hrs and 40 min till 18 June 2023
  • The updates will be added for free and no expiration

Main Training:

  • Part 01 (5 min, April 14, 2022): busbar definition, busbar arrangement (Single Bus-Bar, Single Bus-Bar Arrangement with Bus Sectionalized, single bus station with the transfer bus, double bus-double breaker station, double bus-single breaker, one-and-a-half breaker station, mesh or ring bus station)
  • Part 02 (6 minApril 14, 2022): busbar differential protection function (87BB)
  • Part 03 (8 minApril 14, 2022): Protection Zone, how to analyze busbar differential protection function and simulate different cases.
  • Part 04 (9 minApril 19, 2022): busbar protection for the one-and-a-half breaker arrangement, double busbar system, check zone, ABB Zone operation characteristic, check zone operation, load transfer, Zone Interconnection
  • Part 05 (9 minApril 27, 2022): REB 670 relay, REB670 series hardware structure, function blocks BCZSPDIF and BCZTPDIF configuration and parameters
  • Part 06 (8 minApril 27, 2022): BUSPTRC and BUTPTRC configuration and parameters
  • Part 07 (10 minApril 27, 2022): Zone interconnection BZITGGIO, BZISGGIO; BZNTPDIF, BZNSPDIF or busbar zone Differential protection configuration
  • Part 08 (06 minApril 27, 2022): BZNTPDIF, BZNSPDIF or busbar zone Differential protection parameters, SWSGGIO 87B function block, RADSS schemes, and INX schemes
  • Part 09 (16 minMay 01, 2022): Sample Busbar config in PCM600 Part I
  • Part 10 (19 minMay 01, 2022): Sample Busbar config in PCM600 Part II
  • Part 11: (4 min, 18 June 2023): Review of the previous parts
  • Part 12: (12 min, 18 June 2023): REB670 Application templates and review SLD of a case study project
  • Part 13: (19 min, 18 June 2023): REB 670 Template default configuration A20-X01
  • Part 14: (9 min, 18 June 2023): REB670-B31-X02
  • Part 15: (22 min, 18 June 2023): How to select a proper template based on SLD and how to config and modify based on diagram documents

supplementary Files: To save your time, we’ve gathered critical related files/ videos and attached them to the course as additional files.

  • Busbar protection REB670 2.0 IEC Application Manual
  • Busbar protection REB670 2.0 IEC Commissioning Manual
  • Busbar protection REB670 2.0 IEC Technical Manual
  • SIPROTEC 4 7SS52 Distributed Numerical Busbar and Breaker Failure Protection (catalog)
  • SIPROTEC 4 7SS52 Distributed Numerical Busbar and Breaker Failure Protection (Manual)
  • Busbar Differential Protection, SIPROTEC 7SS60 Centralized Numerical Busbar Protection, SIPROTEC4 7SS52 Distributed Numerical Busbar, and Breaker Failure Protection, SIPROTEC 7SS50 Numerical Busbar, and Breaker Failure Protection, SIPROTEC 7VH60 High-Impedance Differential Protection Relay
  • 01 Busbar Protection Training Introduction
  • 02 Busbar Protection training Bus Configurations
  • 03 Busbar Protection training BB Components
  • 04 Busbar Protection training Low Impedance Schematic1
  • 05 Busbar Protection training Low Impedance Schematic2
  • 06 Busbar Protection training High Impedance Schematic
  • 07 Busbar Protection training Siemens 7SS52
  • 08 Busbar Protection training ABB REB500
  • 09 Busbar Protection training SINGLE Bus Without Coupler
  • 10 Busbar Protection training Double Bus Single Breaker 2 CTs
  • 11 Busbar Protection training Double Bus Single Breaker 1 CT
  • 12 Busbar Protection training CT Location Aux Contacts
  • 13 Busbar Protection training Dead Zone Load Transfer
  • 14 Busbar Protection training Breaker Failure Protection
  • 15 Busbar Protection training EndFault Definition Requirements
  • 16 Busbar Protection training EndFault DoubleBus
  • 17 Busbar Protection training EndFault 1 and Half CB
  • 18 Busbar Protection training High Impedance BBP Setting Calculation
  • 19 Busbar Protection training BBP Stability and Sensitivity Tests
  • Busbar Protection
  • All bus bar schemes in the substation-Busbar system in substation-Power system-Typical bus configuration
  • BusBar Schemes in Electrical Substation Part 1 Bus fault cases operation explained with diagram
  • Bus-Bar Schemes in Electrical Substation Part 2 Bus fault cases operation explained with diagram
  • Differential protection
  • Main and Transfer bus bar Differential Protection – Bus bar protection 7SS85 relay testing
  • Busbar Protection Fundamentals
  • High impedance busbar protection
 IED with two low-impedance differential protection zones and eight three-phase CT inputs

Any queries, please feel free to contact us: saeed61850@gmail.com