C53: Schneider Electric

MiCOM Training

(Created: Dec 2020) (Last update: April 2023) MiCOM Relays Training Package MICOM P123 protection relay has been made to control and protect current and ground faults for overhead and cable lines, and MICOM P441 is one of the distance relays that’s responsible for protection control and monitoring of transmission lines. Through this course, you can […]

MiCOM Training Read More »

MiCOM error codes

Error Code Action to be Taken 0X83810002 Check Software is loaded correctly into the relay. Upgrade the Firmware. 0X83818001 Replaced Analog Opto Card, Ethernet Card, Relay Upgraded,& found Healthy & OK 0x0c0e0000 The relay card is defective. Replace the Relay card. 0x0c250018 Either the Processor Card or Analog Input Card is defective. Replace the Processor

MiCOM error codes Read More »

Easergy Studio video training

Learning is a continuous process and enables us to be competitive in our field. Consistent with this belief and built on a strong experience in this field, we offer video training courses for practicing professionals in the area of Substation Automation and Protection Relays. The material of each course is designed to help you to

Easergy Studio video training Read More »

SEPAM Protection Relays

SEPAM Protection Relays Range       SEPAM 60: For complex power networks SEPAM 60 Datasheet S62 Substation type + Overload & Directional Overcurrent & Earth fault + Active Power T60 Transformer type T62 Transformer type + Directional Overcurrent & Earth fault + Active Power M61 Motor type G60 Generator type G62 Generator type + Directional Overcurrent

SEPAM Protection Relays Read More »

SFT2841

The SFT2841 software is the setting and operating tool for Sepam series 20, Sepam series 40, and Sepam series 80 Relays. It may be used to: Commissioning offline to prepare Sepam protection and parameter settings Load, unload, and modify Sepam protection and parameter settings Obtain all measurements and useful information during commissioning Manage the protection

SFT2841 Read More »

Course on: Sepam Protection Principles

Course definition    TARGETS  Marketing function Protection technician Product Application Engineer (PAE) Application engineer  Objective:   Able to understand and choose the protection functions available in the Sepam range offer in compliance with standards and industrial MV network applications. Theoretical introduction to Sepam series 20, 40, 80 bringing into operation.   Content Introduction of MV dist ibut

Course on: Sepam Protection Principles Read More »