Supplementary Files: The important related files/ videos /software and attached to the course as extra files.

Any queries, please feel free to contact me at: saeed61850@gmail.com

Part A: Introduction, general settings, Hardware & connection, Impedance/Vector/report View, the test object, …

  • A 01 (Length: 02 min, Update: Oct 3, 2021): Introduction
  • A 02 (Length: 05 min, Update: Oct 3, 2021): Strat page (Omicron)
  • A 03 (Length: 06 min, Update: Oct 3, 2021): General settings (Omicron)
  • A 04 (Length: 05 min, Update: Oct 3, 2021): Strat page (Vebko)
  • A 05 (Length: 14 min, Update: Oct 3, 2021): Phasor view, Impedance view (Omicron)
  • A 06 (Length: 06 min, Update: Oct 3, 2021): Phasor view, Impedance view, differential view (Vebko)
  • A 07 (Length: 04 min, Update: Oct 3, 2021): Hardware connection
  • A 08 (Length: 10 min, Update: Oct 3, 2021): Practical section with Omicron 256 plus, SEL 421

Part B: Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)

  • B 01 (Length: 19 min, Update: Oct 3, 2021): Test object, Overcurrent RIO block, testing of overcurrent
  • B 02 (Length: 16 min, Update: Oct 3, 2021): Settings of the Overcurrent test module
  • B 03 (Length: 15 min, Update: Oct 3, 2021): Practical section
  • B 04 (Length: 17 min, Update: Oct 3, 2021): Practical section
  • B 05 (Length: 06 min, Update: Oct 3, 2021): Practical section
  • B 06 (Length: 15 min, Update: Oct 3, 2021): Practical section
  • B 07 (Length: 09 min, Update: Oct 3, 2021): Practical section
  • B 08 (Length: 15 min, Update: Oct 3, 2021): Practical section
  • B 09 (Length: 22 min, Update: Oct 3, 2021): Practical section
  • B 10 (Length: 23 min, Update: Oct 3, 2021): Practical section (directional overcurrent concepts, settings, practice)
  • B 11 (Length: 06 min, Update: Oct 3, 2021): Practical section (directional overcurrent testing)

Part C: Differential Protection Functions (87G, 87T, 87L)

  • C 01 (Length: 03 min, Update: Oct 27, 2021): Diff protection principal
  • C 02 (Length: 11 min, Update: Oct 27, 2021): Diff parameters
  • C 03 (Length: 12 min, Update: Oct 27, 2021): Diff RIO block
  • C 04 (Length: 05 min, Update: Oct 27, 2021): Diff configuration
  • C 05 (Length: 07 min, Update: Oct 27, 2021): Diff Operating Characteristic
  • C 06 (Length: 12 min, Update: Oct 27, 2021): Diff Trip Time Characteristic & Diff Harmonic Restraint

Part D: XRIO and PTL

  • D 01 (Length: 13 min, Update: Nov 13, 2021): RIO and XRIO history and why we should use this format for relay testing, RIO structure, XRIO structure, Differences between RIO and XRIO files, XRIO features & benefits, LinkToXRIO
  • D 02 (Length: 05 min, Update: Nov 13, 2021): XRIO template, How to Import Relay Settings, How to find a proper XRIO template and filter based on the relay
  • D 03 (Length: 08 min, Update: Nov 13, 2021): Common problems while loading the relay settings into a template and how to solve the issues, XRIO template based on the relay versions
  • D 04 (Length: 06 min, Update: Nov 13, 2021): Explain a case study XRIO file
  • D 05 (Length: 10 min, Update: Nov 13, 2021): Modify a case study XRIO file
  • D 06 (Length: 09 min, Update: Nov 13, 2021): Modify the XRIO template, RIO blocks

Part E: Impedance Protection Functions

  • E 01 (Length: 09 min, Update: Nov 26, 2021): Distance RIO block
  • E 02 (Length: 07 min, Update: Nov 26, 2021): Advance Distance Test Module settings
  • E 03 (Length: 08 min, Update: Nov 26, 2021): Distance protection function principal, Impedance View
  • E 04 (Length: 18 min, Update: Nov 26, 2021): Analysis of several faults visually in the impedance view
  • E 05 (Length: 19 min, Update: Nov 26, 2021): Analysis of several distance relays (RAZOA, ABB REL670, SEL421, Siemens 7SA8x, MiCOM P442, NR PCS 931S, Protecta)
  • E 06 (Length: 08 min, Update: Nov 26, 2021): Distance Test Module settings
  • E 07 (Length: 12 min, Update: Nov 26, 2021): Preparing XRIO file for testing of impedance protection functions

Part F: Autoreclosure Function (ANSI 79)

  • F 01 (Length: 04 min, Update: Dec 03, 2021): Autoreclosure Description, auto reclose process
  • F 02 (Length: 05 min, Update: Dec 03, 2021): Autoreclosure settings, Autoreclose timing diagram
  • F 03 (Length: 11 min, Update: Dec 03, 2021): Autoreclosure simulation
  • F 04 (Length: 12 min, Update: Dec 03, 2021): Testing of AR in state sequencer
  • F 05 (Length: 09 min, Update: Dec 03, 2021): Testing of AR in the Autorecoser test module

Part G: Voltage and Frequency Protection Functions (ANSI 27, ANS59, ANSI81O, 81U)

  • G 01 (Length: 06 min, Update: Dec 08, 2021): Ramping test modules and testing the frequency functions
  • G 02 (Length: 05 min, Update: Dec 08, 2021): Paulse ramping test module
  • G 03 (Length: 06 min, Update: Dec 08, 2021): Continous ramp and step ramp
  • G 04 (Length: 11 min, Update: Dec 08, 2021): How to test Over/Under voltage protection functions (59, 27)

Part H: Study functions, testing, and commission of SIPROTEC 7UT6

  • H 01 (Length: 10 min, Update: Dec 20, 2021): SIPROTEC 7UT6 setting description and configuration
  • H 02 (Length: 14 min, Update: Dec 20, 2021): How to test differential function in SIPROTEC 7UT6, No combined characteristic feature, Automate testing by creating SIEMENS 7UT XRIO file
  • H 03 (Length: 18 min, Update: Jan 01, 2022): The procedure of testing transformer protection with Quick CMC

Part K: Study functions, testing, and commission of MiCOM P44x

  • K 01 (Length: 19 min, Update: Oct 31, 2022): Hardware and function description of the MiCOM P441, P442 & P444
  • K 02 (Length: 17 min, Update: Oct 31, 2022): MiCOM Relay connections, communication, and Wire connection test
  • K 03 (Length: 05 min, Update: Nov 1, 2022): Distance protection parameters and testing
  • K 04 (Length: 10 min, Update: Nov 1, 2022): Switch on to fault protection (SOTF) function parameters and testing
Testing and Commissioning of Protective Relays Training

  • Introduction, Software Installation, and general settings
  • Different types of test modules
  • Impedance/Vector/report View, Display settings
  • Test Object, Hardware Configuration
  • RIO, XRIO, and PTL
  • Control Center, How to create and modify XRIO/ PTL files
  • Transient module, Advanced transplay
  • RIO Function Over Current, Define Element Characteristic, Pick-Up/ Drop-Off Test
  • Testing of the Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)
  • Distance Configuration, Settings, Shot Test, Check Test, Search Test, Z\t Diagram, Zone Settings
  • Testing of the Distance function (21)
  • Principle of Differential Protection, Operating Characteristic, Differential Configuration, Differential Operating Characteristic, Differential Trip Time, and Harmonic Restraint
  • Testing of the Differential protection function (87, 87G, 87T)
  • Testing of the Power swing function
  • Autoreclosure, shot and times, unsuccessful / Successful Sequence
  • Testing of the Autorecloser function
  • Testing of the Fault location function
  • Testing of the Over/Under frequency (81O/ 81U)
  • Testing of the Over/Undervoltage (59, 27)
  • Testing of the Pole-Slip function (78)
  • Testing of the Loss of Excitation (40)
  • Testing of the Negative Phase Sequence (46)
  • Testing of the Overload (49)
  • How to test the distance function if the distance module is deactivated in the test universe software
  • How to test differential function if the differential module is deactivated in the test universe
  • Practical sections with testing of the relays (ABB REG670, MiCOM P441, MiCOM P123, …)
Training on Testing and commissioning by Dr. Saeed Roostaee
This image has an empty alt attribute; its file name is IMG_20210517_150836.jpg

The testing & commissioning of the protection relays can be done by different testing software and hardware. In this training, we have used OMICRON Test Universe, Vebko AMpro, and FREJA win.

20 WhatsApp Groups for protection engineers to join:

  • WhatsApp Grp 01: Protection Relay – General
  • WhatsApp Grp 02: Substation Automation – General
  • WhatsApp Grp 03: Transmission line protection
  • WhatsApp Grp 04: Transformer protection
  • WhatsApp Grp 05: Motor protection
  • WhatsApp Grp 06: Generator protection
  • WhatsApp Grp 07: Overcurrent and Earth Fault Protection
  • WhatsApp Grp 08: Busbar protection and Bay controller
  • WhatsApp Grp 09: Breaker protection and control
  • WhatsApp Grp 10: Protection Relay Testing and commissioning
  • WhatsApp Grp 11: DIgSILENT
  • WhatsApp Grp 12: ETAP
  • WhatsApp Grp 13: PSCAD
  • WhatsApp Grp 14: IEC 61850 configuration
  • WhatsApp Grp 15: Switchgear GIS & AIS
  • WhatsApp Grp 16: GE Relay Configuration
  • WhatsApp Grp 17: SIEMENS Relay configuration
  • WhatsApp Grp 18: Schnider Relay configuration
  • WhatsApp Grp 19: SEL Relay Configuration
  • WhatsApp Grp 20: ABB Relion configuration

Click here to join these groups