Skip to main content
  • Trainer: Dr. Saeed Roostaee
  • Comment on this post or contact us for more details
  • Duration: 4 days
  • Type: Face to face

Parts of the course topics:

⦁ Introduction to power system
⦁ The Per-Unit System
⦁ Per Phase Analysis
⦁ Symmetrical Components
⦁ Fourier Transform signal
⦁ Faults in Electrical System
⦁ Consequences of SC Faults
⦁ Types of Electric Faults
⦁ Establishment of SC
⦁ SC Calculation IEC 60909
⦁ Typical Fault criteria
⦁ Intro Power Sys Protection
⦁ Electromechanical Relays
⦁ Numerical Relays
⦁ Current Transformers
⦁ Voltage Transformers
⦁ Overcurrent
⦁ DOC (ANSI 67)
⦁ Coordination
⦁ Earthing
⦁ Line-To-Ground Faults
⦁ Earth Fault 50N 51N
⦁ Sensitive Earth Fault 50Ns 67Ns
⦁ Power Transformer Faults
⦁ Winding & Terminal Failures
⦁ The Effect of Through Faults on Power Transformers
⦁ Tap Changer (OLTC) Failure
⦁ Transform Miscellaneous Failures
⦁ How do we Protect Transformers?
⦁ ABB RET 670
⦁ Differential Protection
⦁ Transformer Differential Protection
⦁ Differences between digital transformer differential relays
⦁ Simulate different cases and test the differential transformer protection function
⦁ Restricted Earth Fault Protection(REF) in Transformer
⦁ High Impedance Restricted Earth Fault Protection working principle
⦁ Stability Resistance and Metrosil Resistance in REF Protection
⦁ Low impedance REF
⦁ Transmission Lines
⦁ Line Constants
⦁ Transmission Line Faults
⦁ How do we Protect Transmission Lines?
⦁ Distance Protection for Transmission Lines
⦁ Earth-Faults and Fault Resistance
⦁ Residual Compensation Factors
⦁ Short Zone
⦁ STUB
⦁ SOTF
⦁ Power Swing
⦁ Tele-Protection and weak infeed
⦁ Fault locator
⦁ Line diff
⦁ ABB REL 670

sdr


⦁ An overview of the PCM 600 functionality as well as how to get the software
⦁ Communication and Project setup, establish communication between the physical IED and PCM 600, Manage project with PCM 600, Hardware configuration
⦁ How to use the Application configuration tool in the PCM 600
⦁ How to use the Graphical Display editor tool in the PCM 600
⦁ How to use the Read and Write tool in the PCM 600
⦁ How to use the user management in the IED and PCM 600
⦁ IED online monitoring, event viewer, signal monitoring, disturbance handling
⦁ signal matrix editor tool in the PCM 600
⦁ The parameter setting tool in the PCM 600
⦁ Writing configuration into IED
⦁ IED compare
⦁ Config a simple distance protection function (SMAI, SMBI, SMBO, ZMMAPDIS, ZMMPDIS, FUFSPVC, …), configure sample signals based on the 7SA diagram
⦁ Config a simple 67N protection function, config disturbance reports (ARDAR, BRDAR, LED)
⦁ Parameter settings, XRIO format
⦁ Product guide for a pre-configured distance relay, and ordering, and modifying pre-configured distance relay based on our projects, Analog inputs (current &s for voltage), Distance Protection functions, and Communication logic
⦁ Current and Voltage protection functions and Earth Fault Protection Communication logic, Circuit Breaker Autorecloser and Tripping logics, Signal Logic and General IED functions, Virtual Binary inputs and outputs, Disturbance report analog and binary inputs
⦁ Function Block ActiveGroup
⦁ Function Block CMMXU
⦁ Function Block DRPRDRE
⦁ Function Block FXDSIGN
⦁ Function Block INTERRSIG
⦁ Function Block LEDGEN
⦁ Function Block LHMICTRL , LocalHMI
⦁ Function Block SINGLECMD
⦁ Function Block SMBI
⦁ Function Block SMBO
⦁ Function Block TESTMODE
⦁ Function Block TIMEERR
⦁ Function Block TIMER
⦁ ABB RET 670 Transformer Protection Application Template
⦁ ABB RET 670 Configuration and T2WPDIF Function block
⦁ ABB RET 670 Parameters and T2WPDIF parameters
⦁ Simulation of the differential protection algorithm in the ABB RET 670 relays


⦁ Omicron Test Universe Start page
⦁ Omicron Test Universe General settings
⦁ Omicron Test Universe Phasor view, Impedance view
⦁ Omicron CMC Hardware connection
⦁ Omicron Test Universe Test object, Overcurrent RIO block, testing of overcurrent
⦁ Omicron Test Universe Settings of the Overcurrent test module
⦁ Omicron Test Universe Diff parameters
⦁ Omicron Test Universe Diff RIO block
⦁ Omicron Test Universe Diff configuration
⦁ Omicron Test Universe Diff Operating Characteristic
⦁ Omicron Test Universe Diff Trip Time Characteristic & Diff Harmonic Restraint
⦁ RIO and XRIO history and why we should use this format for relay testing, RIO structure, XRIO structure, Differences between RIO and XRIO files, XRIO features & benefits, LinkToXRIO
⦁ XRIO template, How to Import Relay Settings, How to find a proper XRIO template and filter based on the relay
⦁ Common problems while loading the relay settings into a template and how to solve the issues, XRIO template based on the relay versions
⦁ Explain a case study XRIO file
⦁ Modify a case study XRIO file
⦁ Modify the XRIO template, RIO blocks
⦁ Distance RIO block
⦁ Advance Distance Test Module settings
⦁ Distance protection function principal, Impedance View
⦁ Analysis of several faults visually in the impedance view
⦁ Analysis of several distance relays (RAZOA, ABB REL670, SEL421, Siemens 7SA8x, MiCOM P442, NR PCS 931S, Protecta)
⦁ Distance Test Module settings
⦁ Preparing XRIO file for testing of impedance protection functions

Content:

Supplementary Files: The important related files/ videos /software and attached to the course as extra files.

Any queries, please feel free to contact me at: saeed61850@gmail.com

Part A: Introduction, general settings, Hardware & connection, Impedance/Vector/report View, the test object, …

  • A 01 (Length: 02 min, Update: Oct 3, 2021): Introduction
  • A 02 (Length: 05 min, Update: Oct 3, 2021): Strat page (Omicron)
  • A 03 (Length: 06 min, Update: Oct 3, 2021): General settings (Omicron)
  • A 04 (Length: 05 min, Update: Oct 3, 2021): Strat page (Vebko)
  • A 05 (Length: 14 min, Update: Oct 3, 2021): Phasor view, Impedance view (Omicron)
  • A 06 (Length: 06 min, Update: Oct 3, 2021): Phasor view, Impedance view, differential view (Vebko)
  • A 07 (Length: 04 min, Update: Oct 3, 2021): Hardware connection
  • A 08 (Length: 10 min, Update: Oct 3, 2021): Practical section with Omicron 256 plus, SEL 421

Part B: Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)

  • B 01 (Length: 19 min, Update: Oct 3, 2021): Test object, Overcurrent RIO block, testing of overcurrent
  • B 02 (Length: 16 min, Update: Oct 3, 2021): Settings of the Overcurrent test module
  • B 03 (Length: 15 min, Update: Oct 3, 2021): Practical section
  • B 04 (Length: 17 min, Update: Oct 3, 2021): Practical section
  • B 05 (Length: 06 min, Update: Oct 3, 2021): Practical section
  • B 06 (Length: 15 min, Update: Oct 3, 2021): Practical section
  • B 07 (Length: 09 min, Update: Oct 3, 2021): Practical section
  • B 08 (Length: 15 min, Update: Oct 3, 2021): Practical section
  • B 09 (Length: 22 min, Update: Oct 3, 2021): Practical section
  • B 10 (Length: 23 min, Update: Oct 3, 2021): Practical section (directional overcurrent concepts, settings, practice)
  • B 11 (Length: 06 min, Update: Oct 3, 2021): Practical section (directional overcurrent testing)

Part C: Differential Protection Functions (87G, 87T, 87L)

  • C 01 (Length: 03 min, Update: Oct 27, 2021): Diff protection principal
  • C 02 (Length: 11 min, Update: Oct 27, 2021): Diff parameters
  • C 03 (Length: 12 min, Update: Oct 27, 2021): Diff RIO block
  • C 04 (Length: 05 min, Update: Oct 27, 2021): Diff configuration
  • C 05 (Length: 07 min, Update: Oct 27, 2021): Diff Operating Characteristic
  • C 06 (Length: 12 min, Update: Oct 27, 2021): Diff Trip Time Characteristic & Diff Harmonic Restraint

Part D: XRIO and PTL

  • D 01 (Length: 13 min, Update: Nov 13, 2021): RIO and XRIO history and why we should use this format for relay testing, RIO structure, XRIO structure, Differences between RIO and XRIO files, XRIO features & benefits, LinkToXRIO
  • D 02 (Length: 05 min, Update: Nov 13, 2021): XRIO template, How to Import Relay Settings, How to find a proper XRIO template and filter based on the relay
  • D 03 (Length: 08 min, Update: Nov 13, 2021): Common problems while loading the relay settings into a template and how to solve the issues, XRIO template based on the relay versions
  • D 04 (Length: 06 min, Update: Nov 13, 2021): Explain a case study XRIO file
  • D 05 (Length: 10 min, Update: Nov 13, 2021): Modify a case study XRIO file
  • D 06 (Length: 09 min, Update: Nov 13, 2021): Modify the XRIO template, RIO blocks

Part E: Impedance Protection Functions

  • E 01 (Length: 09 min, Update: Nov 26, 2021): Distance RIO block
  • E 02 (Length: 07 min, Update: Nov 26, 2021): Advance Distance Test Module settings
  • E 03 (Length: 08 min, Update: Nov 26, 2021): Distance protection function principal, Impedance View
  • E 04 (Length: 18 min, Update: Nov 26, 2021): Analysis of several faults visually in the impedance view
  • E 05 (Length: 19 min, Update: Nov 26, 2021): Analysis of several distance relays (RAZOA, ABB REL670, SEL421, Siemens 7SA8x, MiCOM P442, NR PCS 931S, Protecta)
  • E 06 (Length: 08 min, Update: Nov 26, 2021): Distance Test Module settings
  • E 07 (Length: 12 min, Update: Nov 26, 2021): Preparing XRIO file for testing of impedance protection functions

Part F: Autoreclosure Function (ANSI 79)

  • F 01 (Length: 04 min, Update: Dec 03, 2021): Autoreclosure Description, auto reclose process
  • F 02 (Length: 05 min, Update: Dec 03, 2021): Autoreclosure settings, Autoreclose timing diagram
  • F 03 (Length: 11 min, Update: Dec 03, 2021): Autoreclosure simulation
  • F 04 (Length: 12 min, Update: Dec 03, 2021): Testing of AR in state sequencer
  • F 05 (Length: 09 min, Update: Dec 03, 2021): Testing of AR in the Autorecoser test module

Part G: Voltage and Frequency Protection Functions (ANSI 27, ANS59, ANSI81O, 81U)

  • G 01 (Length: 06 min, Update: Dec 08, 2021): Ramping test modules and testing the frequency functions
  • G 02 (Length: 05 min, Update: Dec 08, 2021): Paulse ramping test module
  • G 03 (Length: 06 min, Update: Dec 08, 2021): Continous ramp and step ramp
  • G 04 (Length: 11 min, Update: Dec 08, 2021): How to test Over/Under voltage protection functions (59, 27)

Part H: Study functions, testing, and commission of SIPROTEC 7UT6

  • H 01 (Length: 10 min, Update: Dec 20, 2021): SIPROTEC 7UT6 setting description and configuration
  • H 02 (Length: 14 min, Update: Dec 20, 2021): How to test differential function in SIPROTEC 7UT6, No combined characteristic feature, Automate testing by creating SIEMENS 7UT XRIO file
  • H 03 (Length: 18 min, Update: Jan 01, 2022): The procedure of testing transformer protection with Quick CMC

Part K: Study functions, testing, and commission of MiCOM P44x

  • K 01 (Length: 19 min, Update: Oct 31, 2022): Hardware and function description of the MiCOM P441, P442 & P444
  • K 02 (Length: 17 min, Update: Oct 31, 2022): MiCOM Relay connections, communication, and Wire connection test
  • K 03 (Length: 05 min, Update: Nov 1, 2022): Distance protection parameters and testing
  • K 04 (Length: 10 min, Update: Nov 1, 2022): Switch on to fault protection (SOTF) function parameters and testing
Testing and Commissioning of Protective Relays Training

  • Introduction, Software Installation, and general settings
  • Different types of test modules
  • Impedance/Vector/report View, Display settings
  • Test Object, Hardware Configuration
  • RIO, XRIO, and PTL
  • Control Center, How to create and modify XRIO/ PTL files
  • Transient module, Advanced transplay
  • RIO Function Over Current, Define Element Characteristic, Pick-Up/ Drop-Off Test
  • Testing of the Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)
  • Distance Configuration, Settings, Shot Test, Check Test, Search Test, Z\t Diagram, Zone Settings
  • Testing of the Distance function (21)
  • Principle of Differential Protection, Operating Characteristic, Differential Configuration, Differential Operating Characteristic, Differential Trip Time, and Harmonic Restraint
  • Testing of the Differential protection function (87, 87G, 87T)
  • Testing of the Power swing function
  • Autoreclosure, shot and times, unsuccessful / Successful Sequence
  • Testing of the Autorecloser function
  • Testing of the Fault location function
  • Testing of the Over/Under frequency (81O/ 81U)
  • Testing of the Over/Undervoltage (59, 27)
  • Testing of the Pole-Slip function (78)
  • Testing of the Loss of Excitation (40)
  • Testing of the Negative Phase Sequence (46)
  • Testing of the Overload (49)
  • How to test the distance function if the distance module is deactivated in the test universe software
  • How to test differential function if the differential module is deactivated in the test universe
  • Practical sections with testing of the relays (ABB REG670, MiCOM P441, MiCOM P123, …)
Training on Testing and commissioning by Dr. Saeed Roostaee
This image has an empty alt attribute; its file name is IMG_20210517_150836.jpg

The testing & commissioning of the protection relays can be done by different testing software and hardware. In this training, we have used OMICRON Test Universe, Vebko AMpro, and FREJA win.

MICOM P123 protection relay has been made to control and protect current and ground faults for overhead and cable lines, and MICOM P441 is one of the distance relays that’s responsible for protection control and monitoring of transmission lines.

Through this course, you can learn how to configure and work with these relays.

  • Online video training
  • Trainer: Dr. Saeed Roostaee (Profile)
  • 4 hrs pre-recorded videos + 4 hrs attached supplementary videos on google drive + data models + PDF files

Part 01: MiCOM relays range, naming, and application

Parts 2-7: exercises with MiCOM P123 and AMT105 setup. Three-phase signals are injected into the relay to test hardware connection and protection functions.

Parts 8-17: exercises with MiCOM P441 and AMT105 (configuration and PSL, event and disturbance recorder, overcurrent protection, voltage protection, negative sequence protection, and distance protection parameters)

Supplementary files attached

  • 01- start working with Easergy Studio in online mode
  • 02- MiCOM Relay Measurements, Event Logs & Disturbance Records
  • 03- Input naming in the Micom relays
  • 04- Communicate with MiCom P139
  • 05- Communicating with MICOM P139 checking the parameters from the front panel
  • 06- Binary input test from MICOM P139 front panel
  • 07- Binary input test from MICOM P139 front Easergy studio
  • 08 Function Parameters in the MICOM P139
  • 09- Overcurrent Function test in the Micom P139
  • 10- Inverse time overcurrent function IDMT test in the MiCOM P139
  • 11- CBF function config and parameters in the Micom P139
  • 12- Autorecoser function config in the MiCOMp139
  • 13- Autorecoser function test in the MiCOMp139
  • 14- Autorecoser function test in the MiCOMp139 By FREJA
  • 15- Under and Over Voltage protection function parameters and testing in the MiCOM P443
  • 16- Overcurrent and Earth Fault protection function parameters and testing in the MiCOM P443
  • 17- DEF protection function parameters and testing in the MiCOM P443
  • 18- Auto recloser function test in the MiCOM P546
  • 19- Trip Scheme in the Micom P546
  • 20- SOTF in the Micom P546
  • 21- MICOM P546 Differential protection test
  • 22- MICOM P546 Syncro Check
MiCOM P123 front panel
Easergy Studio

Certificate of Completion

After activating the MiCOM training pack on your system, we will issue your certificate for the course.

Test Universe is one of the software tools for settings-based testing of protection relays. By knowing new things in the field of Substation Automation and Protection Relays, you can be sure that you’re professional and up to date.

OMICRON Test Universe Video Training

Language: English
Trainer: Dr. Saeed Roostaee (Profile on Linkedin)
More details and download: https://elec-engg.com/testing-and-commissioning-of-protective-relays/