DIGSI 4, DIGSI 5, and IEC 61850 are the versatile engineering tools for parameterization, commissioning, and operating all SIPROTEC 5 devices. These Simple connections to the device via USB make work more enjoyable for you.

Learning is a continuous process and knowing how to work with these innovative user interfaces enables us to work with a device easily and efficiently and make you a professional engineer in this field. Consistent with this belief and built on a strong experience in this field, we offer video training courses for practicing professionals in the area of Substation Automation and Protection Relays. The material of each course is designed to help you and the training items are as follows:

Product Detail:

  • DIGSI 4 video training
  • DIGSI 5 video training
  • IEC 61850 training 
  • Trainer: Dr. Saeed Roostae

                                                                                                                                                                  

SIPROTEC 4 and DIGSI 4 Training package ( 3hrs – 830 MB)
IEC 61850 Configuration (4 hrs- 1.5 GB)
SIPROTEC 4 and DIGSI 5 training package (7 hrs – 1.8 GB)
NAMElength
Part 1: Substation Automation – an overview 05:39   
Part 2: An introduction to IEC 61850 & how to learn it effectively08:52
Part 3: Overview of the main features of IEC 61850 – Part I08:58
Part 4: Overview of the main features of IEC 61850 – Part II05:41
Part 5: IEC 61850 data structure and data format – Part I33:34
Part 6: IEC 61850 data structure and data format – Part II11:37
Part 7: IEC 61850 station in DIGSI 5 and IEC 61850 System Configurator17:33
Part 8: GOOSE configuration and the publisher/subscriber LNs14:34
Part 9: GOOSE simulation via IEDScout06:31
Part 10: GOOSE configuration and simulation between SIP 5 & SEL relays13:05
Part 11: Time synchronization settings and SNTP configuration10:36
Part 12: Case study – Part I14:56
Part 13: Case study – Part II29:09
Part 14: Case study – Part III23:41
Part 15: IEC 61850 configuration in DIGSI 420:03
Part 16: IEC 61850 configuration between SIP 4 & SIP 512:36
Part 17: Sample project08:56

IEC 61850 Configuration (4 hrs- 1.5 GB)
NAMElength
Part 1: How to install DIGSI 401:57
PART 2: Introduction to SIPROTEC Relay families06:50
Part 3: wiring connection03:02
Part 4: start with DIGSI19:12
part 5: Archive, import, export12:36
Part 6 : Masking I/O11:00
Part 7 : Masking I/O04:51
Part 8 : Masking I/O13:08
Part 9 : Default and Control Display16:21
Part 10 : CFC11:57
Part 11 : CFC and Implementation of experimental example07:59
Part 12 : CFC Interlocking Example04:26
Part 13 : CFC Protection Example04:13
Part 14 : CFC Explanation of all blocks11:01
Part 15 : Power system data 108:34
Part 16 : Setting Group19:13
Part 17 : Oscillographic Fault Recorders03:06
Part 18 : General Device Settings04:39
Part 19 : Time Synchroniztion and Interfaces03:40
Part 20 : Device Driver and Firmware Update09:04
Part 21 : Config SIPROTEC relay in a Practical Project14:36

DIGSI 4 Online Training

NAMElength
part 1: SIPROTEC 5 relay families and applications08:42
part 2: The online SIPROTEC 5 configurator24:20
part 3: DIGSI 5 installation04:27
part 4: DIGSI 5 upgradeand import device drivers07:36
part 5: DIGSI 5 Vs DIGSI 416:05
Part 6:User interface and general setting14:24
part 7: Case study relay configuration- part 116:57
part 8: SIPROTEC 5 Offline configuration I15:31
part 9: Import specific communication driver & inconsistencies05:28
part 10: case study relay configuration- part 218:05
part 11: Distance relay configuration I09:45
part 12: Distance relay configuration II15:50
part 13: Distance relay configuration III 07:13
part 14: Function in DIGSI 516:07
part 15: case study relay configuration- part 312:40
part 16: case study relay configuration- part 405:48
part 17: case study relay configuration- part 515:57
part 18: case study relay configuration- part 617:45
part 19: Display Page configuration15:38
part 20: case study relay configuration- part 710:06
part 21: CFC Configuration09:08
part 22: CFC Analysis06:13
part 23: CFC in DIGSI 5 and DIGSI 408:33
part 24: case study relay configuration- part 807:06
part 25: Case study busbar configuration- part 112:53
part 26: Case study busbar configuration- part 216:05
part 27: Case study busbar configuration- part 317:14
part 28: Case study busbar configuration- part 410:31
part 29: Case study busbar configuration- part 512:29
part 30: Case study busbar configuration- part 615:12
part 31: Case study busbar configuration- part 712:23
part 32: Case study busbar configuration- part 811:20
part 33: Case study busbar configuration- part 910:06
part 34: Case study busbar configuration- part 1009:48
part 35: Case study busbar configuration- part 1109:30

SIPROTEC 4 and DIGSI 5 training package