Skip to main content

SIPROTEC 5 & DIGSI 5 Training Course

  • Video-based (pre-recorded)
  • Trainer: Dr. Saeed Roostaee (Profile)
  • Course creation: Nov 2018
  • Last update: 9 September 2023
  • Total Time till July 2023: 9 hrs and 25 min
  • + Auxiliary Files
  • + Certificate of completion
  • + Technical Support

DIGSI 5 Training updateLength
Update 01: SIPROTEC 5 Hardware, Front panel20:47
Update 02: SIPROTEC 5 Hardware- Expansion modules23:47
Update 03: SIPROTEC 5 Applications13:02
Update 04: DIGSI 5 optimal installation, DIGSI 5 Upgrade19:23
Update 05: DIGSI 5 General Settings04:01
Update 06: DIGSI 5 user interface 04:55
Update 07: SIPROTEC 5 Offline Configuration11:12
Update 08: SIPROTEC 5 Online Configuration07:17
Update 09: SIPROTEC 5 and SIPROTEC 5 compact online configuration19:16
Update 10: SIPROTEC 5 Web User Interface 16:45
Update time till July 2023:2.5 hrs

DIGSI 5 Training list:

NAMELength
Part 01: SIPROTEC 5 relay families and applications08:42
Part 2: The online SIPROTEC 5 configurator24:20
Part 3: DIGSI 5 installation04:27
Part 4: DIGSI 5 upgrade and import device drivers07:36
Part 5: DIGSI 5 Vs DIGSI 416:05
Part 6:User interface and general setting14:24
Part 7: Case study relay configuration- part 116:57
Part 8: SIPROTEC 5 Offline Configuration 15:31
Part 9: Import specific communication drivers & inconsistencies05:28
Part 10: case study relay configuration- part 218:05
Part 11: Distance relay configuration I09:45
Part 12: Distance relay configuration II15:50
Part 13: Distance relay configuration III07:13
Part 14: Function in DIGSI 516:07
Part 15: case study relay configuration- part 312:40
Part 16: case study relay configuration- part 405:48
Part 17: case study relay configuration- part 515:57
Part 18: case study relay configuration- part 617:45
Part 19: Display Page configuration15:38
Part 20: case study relay configuration- part 710:06
Part 21: CFC Configuration09:08
Part 22: CFC Analysis06:13
Part 23: CFC in DIGSI 5 and DIGSI 408:33
Part 24: case study relay configuration- part 807:06
Part 25: Case study busbar configuration- part 112:53
Part 26: Case study busbar configuration- part 216:05
Part 27: Case study busbar configuration- part 317:14
Part 28: Case study busbar configuration- part 410:31
Part 29: Case study busbar configuration- part 512:29
Part 30: Case study busbar configuration- part 615:12
Part 31: Case study busbar configuration- part 712:23
Part 32: Case study busbar configuration- part 811:20
Part 33: Case study busbar configuration- part 910:06
Part 34: Case study busbar configuration- part 1009:48
Part 35: Case study busbar configuration- part 1109:30
Total Time7 hrs

Demo

send a request to saeed61850@gmail.com

why DIGSI 5 Training Pack?

  • you have lifetime access to the files.
  • you can start your learning from wherever you are.
  • You can save time and money.
  • you get a certificate of completion. 
  • you can get free updates automatically.

Learning SIPROTEC 5 & DIGSI 5 with ease

Learning DIGSI 5 and SIPROTEC 5 relays becomes easier and more effective when the course is updated continuously and you can learn it anywhere. This course is pre-recorded, and all updates will be added for free.

DIGSI 5 Training Package:

Update 10: SIPROTEC 5 Web User Interface

SIPROTEC 5 and DIGSI 5 training package

Click here to download the Professional package (DIGSI4, DIGSI5, IEC61850)

SIPROTEC 5 relay families and applications; How to install, transfer License and upgrade DIGSI 5; Import DIGSI 5, Device Drivers and Start with DIGSI 5
DIGSI 4 VS DIGSI 5 and DIGSI 5 Overview; Online and Offline SIPROTEC 5 Configurator; Functional Scope and Function Points; Working with Libraries and Elements; Managing Projects and Devices in Projects
Single-Line Configuration; Signals; Information Routing; Routing Measuring Points; Function Charts (CFC); Display Page; Advantages and Disadvantages of SIPROTEC 5 and DIGSI 5; Case study project; Configure SIPROTEC 5 Devices based on diagrams.

Sample DIGSI 5 logs

Library Global DIGSI 5 Library was opened
Project SaeedRoostaee_digsi5training opened
Analyzed compatibility information
6MU85 configuration requires 0 function points

Starting import of function chart(s) (CFC) from file C:\User
Importing log messages for function chart (CFC) Group warning,
Importing log messages for function chart (CFC) Process mode inactive,
Successfully finished importing
Analyzed software part.,7/27/2023,10:08:10 AM
Line Mode has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping, and Information routing.,7/27/2023,10:08:16 AM
DIGSI has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping, and Information routing.,7/27/2023,10:08:17 AM
Web UI has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping, and Information routing.
Analyzed compatibility information.,7/27/2023,10:09:11 AM
6MU85 configuration requires 0 function points.,7/27/2023,10:09:11 AM
6MU85 configuration requires 0 function points.,7/27/2023,10:09:11 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\3vawjx0o.yc3.tmp into device 6MU85.,7/27/2023,10:09:24 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:09:24 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:09:24 AM
Successfully finished importing.,7/27/2023,10:09:24 AM
Analyzed software part.,7/27/2023,10:09:25 AM
Due to a change in hardware, 1 routing was deleted.,7/27/2023,10:09:28 AM
Line Mode has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping, and Information routing.,7/27/2023,10:09:32 AM
DIGSI has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:09:32 AM
Web UI has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:09:33 AM
Analyzed compatibility information.,7/27/2023,10:10:07 AM
6MU85 configuration requires 0 function points.
6MU85 configuration requires 0 function points.,7/27/2023,10:10:07 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\u2zboyex.sai.tmp into device 6MU85.,7/27/2023,10:10:21 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:10:21 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:10:21 AM
Successfully finished importing.,7/27/2023,10:10:22 AM
6MU85 configuration requires 20 function points.,7/27/2023,10:10:22 AM
Analyzed software part.,7/27/2023,10:10:22 AM
Due to change in hardware, 1 routings were deleted.,7/27/2023,10:10:25 AM
Line Mode has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:10:29 AM
DIGSI has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:10:30 AM
Web UI has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:10:30 AM
Analyzed compatibility information.,7/27/2023,10:11:01 AM
6MU85 configuration requires 0 function points.,7/27/2023,10:11:01 AM
6MU85 configuration requires 0 function points.,7/27/2023,10:11:01 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\i5dxb3f4.p3z.tmp into device 6MU85.,7/27/2023,10:11:11 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:11:11 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:11:11 AM
Successfully finished importing.,7/27/2023,10:11:11 AM
Analyzed software part.,7/27/2023,10:11:12 AM
Line Mode has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:11:17 AM
DIGSI has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:11:18 AM
Web UI has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:11:18 AM
Analyzed compatibility information.,7/27/2023,10:11:50 AM
6MU85 configuration requires 0 function points.,7/27/2023,10:11:50 AM
6MU85 configuration requires 0 function points.,7/27/2023,10:11:50 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\kd145sd3.5vv.tmp into device 6MU85.
Importing log messages for function chart (CFC) Group warning
Importing log messages for function chart (CFC) Process mode inactive,
Successfully finished importing.,7/27/2023,10:11:57 AM
Analyzed software part.
Line Mode has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:12:01 AM
DIGSI has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:12:02 AM
Web UI has no settings, so it is not listed under Settings. It is displayed in the Single-line configuration, Communication mapping and Information routing.,7/27/2023,10:12:02 AM
Function-chart (CFC) compilation,7/27/2023,10:13:01 AM
The project SaeedRoostaee_digsi5training was saved successfully.,7/27/2023,10:15:57 AM
Analyzed compatibility information.,7/27/2023,10:16:38 AM
7UM85 configuration requires 0 function points.,7/27/2023,10:16:38 AM
7UM85 configuration requires 0 function points.,7/27/2023,10:16:38 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\4fklxd5f.hx1.tmp into device 7UM85.,7/27/2023,10:16:59 AM
Analyzed software part.,7/27/2023,10:17:01 AM
Analyzed compatibility information.,7/27/2023,10:18:41 AM
7UM85 configuration requires 0 function points.,7/27/2023,10:18:41 AM
7UM85 configuration requires 0 function points.,7/27/2023,10:18:41 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\q1grapr5.1rp.tmp into device 7UM85.,7/27/2023,10:19:05 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:19:05 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:19:05 AM
Successfully finished importing.,7/27/2023,10:19:05 AM
7UM85 configuration requires 85 function points.,7/27/2023,10:19:06 AM
Analyzed software part.,7/27/2023,10:19:06 AM


Analyzed compatibility information.,7/27/2023,10:20:28 AM
7UM85 configuration requires 0 function points.,7/27/2023,10:20:28 AM
7UM85 configuration requires 0 function points.,7/27/2023,10:20:28 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\1e0gnksz.mfz.tmp into device 7UM85.,7/27/2023,10:20:55 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:20:55 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:20:55 AM
Successfully finished importing.,7/27/2023,10:20:55 AM
7UM85 configuration requires 105 function points.,7/27/2023,10:20:56 AM
Analyzed software part.,7/27/2023,10:20:56 AM
Analyzed compatibility information.,7/27/2023,10:21:48 AM
7UM85 configuration requires 0 function points.,7/27/2023,10:21:48 AM
7UM85 configuration requires 0 function points.,7/27/2023,10:21:48 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\yzrziyf1.5ct.tmp into device 7UM85.,7/27/2023,10:22:26 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:22:26 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:22:26 AM
Successfully finished importing.,7/27/2023,10:22:26 AM
7UM85 configuration requires 330 function points.,7/27/2023,10:22:27 AM
Analyzed software part.,7/27/2023,10:22:29 AM
Analyzed compatibility information.,7/27/2023,10:23:24 AM
7UM85 configuration requires 0 function points.,7/27/2023,10:23:24 AM
7UM85 configuration requires 0 function points.,7/27/2023,10:23:24 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\g5ojtdjt.axj.tmp into device 7UM85.,7/27/2023,10:23:53 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:23:53 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:23:54 AM
Successfully finished importing.,7/27/2023,10:23:54 AM
7UM85 configuration requires 255 function points.,7/27/2023,10:23:55 AM
Analyzed software part.,7/27/2023,10:23:55 AM
The project SaeedRoostaee_digsi5training was saved successfully.,7/27/2023,10:25:01 AM
Analyzed compatibility information.,7/27/2023,10:26:38 AM
7VU85 configuration requires 0 function points.,7/27/2023,10:26:38 AM
7VU85 configuration requires 0 function points.,7/27/2023,10:26:38 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\htzmdc0f.3i1.tmp into device 7VU85.,7/27/2023,10:26:56 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:26:56 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:26:56 AM
Successfully finished importing.,7/27/2023,10:26:57 AM
Analyzed software part.,7/27/2023,10:26:57 AM
Analyzed compatibility information.,7/27/2023,10:27:59 AM
7VU85 configuration requires 0 function points.,7/27/2023,10:27:59 AM
7VU85 configuration requires 0 function points.,7/27/2023,10:27:59 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\djy2bv1q.rly.tmp into device 7VU85.,7/27/2023,10:28:29 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:28:29 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:28:30 AM
Successfully finished importing.,7/27/2023,10:28:30 AM
7VU85 configuration requires 470 function points.,7/27/2023,10:28:31 AM
Analyzed software part.,7/27/2023,10:28:32 AM
Analyzed compatibility information.,7/27/2023,10:29:16 AM
7VU85 configuration requires 0 function points.,7/27/2023,10:29:16 AM
7VU85 configuration requires 0 function points.,7/27/2023,10:29:16 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\drdplp2d.gqq.tmp into device 7VU85.,7/27/2023,10:29:44 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:29:44 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:29:45 AM
Successfully finished importing.,7/27/2023,10:29:45 AM
7VU85 configuration requires 400 function points.,7/27/2023,10:29:45 AM
Analyzed software part.,7/27/2023,10:29:46 AM
The project SaeedRoostaee_digsi5training was saved successfully.,7/27/2023,10:30:09 AM
The project SaeedRoostaee_digsi5training was saved successfully.,7/27/2023,10:30:47 AM
Analyzed compatibility information.,7/27/2023,10:32:33 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:32:33 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:32:33 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\4ynlrvko.squ.tmp into device 7VE85.,7/27/2023,10:32:46 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:32:46 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:32:46 AM
Successfully finished importing.,7/27/2023,10:32:46 AM
Analyzed software part.,7/27/2023,10:32:47 AM
Analyzed compatibility information.,7/27/2023,10:33:33 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:33:33 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:33:33 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\h4jl3ijd.fox.tmp into device 7VE85.,7/27/2023,10:33:53 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:33:53 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:33:54 AM
Successfully finished importing.,7/27/2023,10:33:54 AM
7VE85 configuration requires 75 function points.,7/27/2023,10:33:54 AM
Analyzed software part.,7/27/2023,10:33:55 AM
Analyzed compatibility information.,7/27/2023,10:34:28 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:34:28 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:34:28 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\rlvnzip1.5zo.tmp into device 7VE85.,7/27/2023,10:34:44 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:34:44 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:34:45 AM
Successfully finished importing.,7/27/2023,10:34:45 AM
7VE85 configuration requires 115 function points.,7/27/2023,10:34:46 AM
Analyzed software part.,7/27/2023,10:34:47 AM
Analyzed compatibility information.,7/27/2023,10:35:58 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:35:58 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:35:58 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\d1etzmsn.mav.tmp into device 7VE85.,7/27/2023,10:36:15 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:36:15 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:36:15 AM
Successfully finished importing.,7/27/2023,10:36:15 AM
7VE85 configuration requires 115 function points.,7/27/2023,10:36:16 AM
Analyzed software part.,7/27/2023,10:36:17 AM
Analyzed compatibility information.,7/27/2023,10:37:18 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:37:18 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:37:18 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\hysu15dy.clo.tmp into device 7VE85.,7/27/2023,10:37:41 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:37:41 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:37:41 AM
Importing log messages for function chart (CFC) VoltageSelection,7/27/2023,10:37:41 AM
Successfully finished importing.,7/27/2023,10:37:42 AM
7VE85 configuration requires 115 function points.,7/27/2023,10:37:42 AM
Analyzed software part.,7/27/2023,10:37:42 AM
Analyzed compatibility information.,7/27/2023,10:38:47 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:38:47 AM
7VE85 configuration requires 0 function points.,7/27/2023,10:38:47 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\c0jkcjzm.ff4.tmp into device 7VE85.,7/27/2023,10:39:13 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,10:39:13 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,10:39:14 AM
Successfully finished importing.,7/27/2023,10:39:14 AM
7VE85 configuration requires 230 function points.,7/27/2023,10:39:14 AM
Analyzed software part.,7/27/2023,10:39:15 AM
Due to change in hardware, 15 routings were deleted.,7/27/2023,10:39:21 AM
The project SaeedRoostaee_digsi5training was saved successfully.,7/27/2023,10:40:17 AM
Analyzed compatibility information.,7/27/2023,10:42:05 AM
7SX85 configuration requires 0 function points.,7/27/2023,10:42:05 AM
7SX85 configuration requires 0 function points.,7/27/2023,10:42:05 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\rwtxsokr.dq5.tmp into device 7SX85.,7/27/2023,10:42:24 AM
7SX85 configuration requires 74 function points.,7/27/2023,10:42:25 AM
Analyzed software part.,7/27/2023,10:42:26 AM
Analyzed compatibility information.,7/27/2023,10:43:04 AM
7SX85 configuration requires 0 function points.,7/27/2023,10:43:04 AM
7SX85 configuration requires 0 function points.,7/27/2023,10:43:04 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\bhr4svo1.p0w.tmp into device 7SX85.,7/27/2023,10:43:27 AM
7SX85 configuration requires 126 function points.,7/27/2023,10:43:27 AM
Analyzed software part.,7/27/2023,10:43:28 AM
The project SaeedRoostaee_digsi5training was saved successfully.,7/27/2023,10:44:17 AM
Analyzed compatibility information.,7/27/2023,11:00:39 AM
6MD86 configuration requires 0 function points.,7/27/2023,11:00:39 AM
6MD86 configuration requires 0 function points.,7/27/2023,11:00:40 AM
Analyzed software part.,7/27/2023,11:00:46 AM
Analyzed compatibility information.,7/27/2023,11:01:09 AM
6MD86_1 configuration requires 0 function points.,7/27/2023,11:01:09 AM
6MD86_1 configuration requires 0 function points.,7/27/2023,11:01:09 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\oua4evsi.ttf.tmp into device 6MD86_1.,7/27/2023,11:01:28 AM
Analyzed software part.,7/27/2023,11:01:30 AM
Analyzed compatibility information.,7/27/2023,11:02:29 AM
6MD86 configuration requires 0 function points.,7/27/2023,11:02:29 AM
6MD86 configuration requires 0 function points.,7/27/2023,11:02:29 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\erexcpgi.y4l.tmp into device 6MD86.,7/27/2023,11:03:15 AM
Analyzed software part.,7/27/2023,11:03:20 AM
Due to change in hardware, 29 routings were deleted.,7/27/2023,11:03:32 AM
Analyzed compatibility information.,7/27/2023,11:04:08 AM
6MD86 configuration requires 0 function points.,7/27/2023,11:04:08 AM
6MD86 configuration requires 0 function points.,7/27/2023,11:04:08 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\vowhsuzk.axy.tmp into device 6MD86.,7/27/2023,11:04:48 AM
6MD86 configuration requires 60 function points.,7/27/2023,11:04:50 AM
Analyzed software part.,7/27/2023,11:04:51 AM
Due to change in hardware, 23 routings were deleted.,7/27/2023,11:05:00 AM
Analyzed compatibility information.,7/27/2023,11:06:19 AM
6MD86 configuration requires 0 function points.,7/27/2023,11:06:19 AM
6MD86 configuration requires 0 function points.,7/27/2023,11:06:19 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\wojcjuzy.cux.tmp into device 6MD86.,7/27/2023,11:06:36 AM
Importing log messages for function chart (CFC) GRPWARN_POW,7/27/2023,11:06:36 AM
Importing log messages for function chart (CFC) PROCESS_MODE_INACTIVE,7/27/2023,11:06:36 AM
Successfully finished importing.,7/27/2023,11:06:36 AM
6MD86 configuration requires 200 function points.,7/27/2023,11:06:37 AM
Analyzed software part.,7/27/2023,11:06:37 AM
Analyzed compatibility information.,7/27/2023,11:25:01 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:25:01 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:25:01 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\fk53a1ei.qb0.tmp into device 7UT87.,7/27/2023,11:25:20 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:25:20 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:25:21 AM
Successfully finished importing.,7/27/2023,11:25:21 AM
Analyzed software part.,7/27/2023,11:25:22 AM
Analyzed compatibility information.,7/27/2023,11:26:30 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:26:30 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:26:30 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\4h5nmjbt.upq.tmp into device 7UT87.,7/27/2023,11:26:54 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:26:54 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:26:54 AM
Successfully finished importing.,7/27/2023,11:26:55 AM
7UT87 configuration requires 25 function points.,7/27/2023,11:26:55 AM
Analyzed software part.,7/27/2023,11:26:56 AM
Analyzed compatibility information.,7/27/2023,11:28:30 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:28:30 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:28:30 AM
Starting import of function chart(s) (CFC) from file

SIPROTEC 5 and DIGSI 5 training by Dr. Saeed Roostaee

C:\Users\LENOVO\AppData\Local\Temp\zf1oyw44.fey.tmp into device 7UT87.,7/27/2023,11:28:58 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:28:58 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:28:58 AM
Successfully finished importing.,7/27/2023,11:28:59 AM
7UT87 configuration requires 30 function points.,7/27/2023,11:28:59 AM
Analyzed software part.,7/27/2023,11:29:00 AM
Analyzed compatibility information.,7/27/2023,11:29:41 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:29:42 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:29:42 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\kocertsc.mb2.tmp into device 7UT87.,7/27/2023,11:30:10 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:30:10 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:30:11 AM
Successfully finished importing.,7/27/2023,11:30:11 AM
7UT87 configuration requires 170 function points.,7/27/2023,11:30:11 AM
Analyzed software part.,7/27/2023,11:30:12 AM
Analyzed compatibility information.,7/27/2023,11:30:46 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:30:46 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:30:46 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\g1vz3iv4.n3x.tmp into device 7UT87.,7/27/2023,11:31:13 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:31:13 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:31:13 AM
Successfully finished importing.,7/27/2023,11:31:13 AM
7UT87 configuration requires 50 function points.,7/27/2023,11:31:14 AM
Analyzed software part.,7/27/2023,11:31:14 AM
Analyzed compatibility information.,7/27/2023,11:31:47 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:31:47 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:31:47 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\mueys0vx.wkm.tmp into device 7UT87.,7/27/2023,11:32:14 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:32:14 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:32:15 AM
Successfully finished importing.,7/27/2023,11:32:16 AM
Analyzed software part.,7/27/2023,11:32:17 AM
Analyzed compatibility information.,7/27/2023,11:33:01 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:33:01 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:33:01 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\o2l40wo1.1qd.tmp into device 7UT87.,7/27/2023,11:33:39 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:33:39 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:33:40 AM
Successfully finished importing.,7/27/2023,11:33:40 AM
7UT87 configuration requires 45 function points.,7/27/2023,11:33:40 AM
Analyzed software part.,7/27/2023,11:33:41 AM
Analyzed compatibility information.,7/27/2023,11:34:32 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:34:32 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:34:32 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\bx5kvvoj.idx.tmp into device 7UT87.,7/27/2023,11:35:16 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:35:16 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:35:16 AM
Importing log messages for function chart (CFC) DIS_Z4_trip_all_CB,7/27/2023,11:35:16 AM
Successfully finished importing.,7/27/2023,11:35:16 AM
7UT87 configuration requires 150 function points.,7/27/2023,11:35:17 AM
Analyzed software part.,7/27/2023,11:35:19 AM
Analyzed compatibility information.,7/27/2023,11:39:39 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:39:39 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:39:39 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\nwlj1jve.e4e.tmp into device 7UT87.,7/27/2023,11:40:12 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:40:12 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:40:13 AM
Successfully finished importing.,7/27/2023,11:40:13 AM
7UT87 configuration requires 30 function points.,7/27/2023,11:40:13 AM
Analyzed software part.,7/27/2023,11:40:14 AM
Analyzed compatibility information.,7/27/2023,11:41:13 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:41:13 AM
7UT87 configuration requires 0 function points.,7/27/2023,11:41:13 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\s20dfpoq.2kd.tmp into device 7UT87.,7/27/2023,11:41:59 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:41:59 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:42:00 AM
Successfully finished importing.,7/27/2023,11:42:00 AM
7UT87 configuration requires 30 function points.,7/27/2023,11:42:01 AM
Analyzed software part.,7/27/2023,11:42:02 AM
Assignment of offline configuration 7UT87_3_2W 1.5 to another offline configuration 7UT87_1_2W basic is not possible. Assign always online devices to offline configurations.,7/27/2023,11:43:08 AM
The project SaeedRoostaee_digsi5training was saved successfully.,7/27/2023,11:43:56 AM
Analyzed compatibility information.,7/27/2023,11:45:51 AM
7SS85 configuration requires 0 function points.,7/27/2023,11:45:51 AM
7SS85 configuration requires 0 function points.,7/27/2023,11:45:51 AM
Starting import of function chart(s) (CFC) from file

C:\Users\LENOVO\AppData\Local\Temp\1lwlt0co.g3s.tmp into device 7SS85.,7/27/2023,11:46:01 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:46:01 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:46:01 AM
Successfully finished importing.,7/27/2023,11:46:01 AM
Analyzed software part.,7/27/2023,11:46:01 AM
Analyzed compatibility information.,7/27/2023,11:46:52 AM
7VK87 configuration requires 0 function points.,7/27/2023,11:46:52 AM
7VK87 configuration requires 0 function points.,7/27/2023,11:46:52 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\gpn2w0ns.wbw.tmp into device 7VK87.,7/27/2023,11:47:13 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:47:13 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:47:14 AM
Successfully finished importing.,7/27/2023,11:47:14 AM
Analyzed software part.,7/27/2023,11:47:15 AM
Analyzed compatibility information.,7/27/2023,11:48:11 AM
7SL87 configuration requires 0 function points.,7/27/2023,11:48:11 AM
7SL87 configuration requires 0 function points.,7/27/2023,11:48:11 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\by51qi0y.yx1.tmp into device 7SL87.,7/27/2023,11:48:32 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:48:32 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:48:33 AM
Successfully finished importing.,7/27/2023,11:48:33 AM
Analyzed software part.,7/27/2023,11:48:34 AM
Analyzed compatibility information.,7/27/2023,11:49:10 AM
7SL87 configuration requires 0 function points.,7/27/2023,11:49:10 AM
7SL87 configuration requires 0 function points.,7/27/2023,11:49:10 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\ojyjebnh.0lh.tmp into device 7SL87.,7/27/2023,11:49:41 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:49:41 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:49:42 AM
Successfully finished importing.,7/27/2023,11:49:42 AM
7SL87 configuration requires 225 function points.,7/27/2023,11:49:43 AM
Analyzed software part.,7/27/2023,11:49:44 AM
Analyzed compatibility information.,7/27/2023,11:50:19 AM
7SL87 configuration requires 0 function points.,7/27/2023,11:50:19 AM
7SL87 configuration requires 0 function points.,7/27/2023,11:50:20 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\znrrm0rx.ugj.tmp into device 7SL87.,7/27/2023,11:50:59 AM
Importing log messages for function chart (CFC) DISCON_7SL87_7SD87,7/27/2023,11:50:59 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:50:59 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:51:00 AM
Importing log messages for function chart (CFC) RECL_7SX87_1,7/27/2023,11:51:00 AM
Importing log messages for function chart (CFC) RECL_7SX87_2,7/27/2023,11:51:00 AM
Successfully finished importing.,7/27/2023,11:51:01 AM
7SL87 configuration requires 400 function points.,7/27/2023,11:51:01 AM
Analyzed software part.,7/27/2023,11:51:03 AM
The project SaeedRoostaee_digsi5training was saved successfully.,7/27/2023,11:51:57 AM
Analyzed compatibility information.,7/27/2023,11:52:29 AM
7SD87 configuration requires 0 function points.,7/27/2023,11:52:29 AM
7SD87 configuration requires 0 function points.,7/27/2023,11:52:29 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\u2lbfpnj.14x.tmp into device 7SD87.,7/27/2023,11:52:49 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:52:49 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:52:50 AM
Successfully finished importing.,7/27/2023,11:52:50 AM
Analyzed software part.,7/27/2023,11:52:51 AM
Analyzed compatibility information.,7/27/2023,11:53:34 AM
7SD87 configuration requires 0 function points.,7/27/2023,11:53:34 AM
7SD87 configuration requires 0 function points.,7/27/2023,11:53:34 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\ti4eq0z4.04y.tmp into device 7SD87.,7/27/2023,11:53:58 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:53:58 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:53:59 AM
Successfully finished importing.,7/27/2023,11:53:59 AM
7SD87 configuration requires 170 function points.,7/27/2023,11:53:59 AM
Analyzed software part.,7/27/2023,11:54:00 AM
Analyzed compatibility information.,7/27/2023,11:54:43 AM
7SD87 configuration requires 0 function points.,7/27/2023,11:54:43 AM
7SD87 configuration requires 0 function points.,7/27/2023,11:54:43 AM
Starting import of function chart(s) (CFC) from file C:\Users\LENOVO\AppData\Local\Temp\qytlw5aa.tuf.tmp into device 7SD87.,7/27/2023,11:55:18 AM
Importing log messages for function chart (CFC) DISCON_7SL87_7SD87,7/27/2023,11:55:18 AM
Importing log messages for function chart (CFC) Group warning,7/27/2023,11:55:19 AM
Importing log messages for function chart (CFC) Process mode inactive,7/27/2023,11:55:20 AM
Importing log messages for function chart (CFC) RECL_7SX87_1,7/27/2023,11:55:20 AM
Importing log messages for function chart (CFC) RECL_7SX87_2,7/27/2023,11:55:20 AM
Successfully finished importing.,7/27/2023,11:55:21 AM
7SD87 configuration requires 345 function points.
Analyzed software part.,
The project SaeedRoostaee_digsi5training was saved successfully.

Information

  • Course Name: SIPROTEC 5 and DIGSI 5 (advanced)
  • Trainer: Dr. Saeed Roostaee
  • Format: Pre-recorded videos (demo is available)
  • Course creation: June 2023
  • Last update: July 2023

Note: This course can also be held either Online or Face to face based on the request

Course Structure:

  • Module 1: SIPROTEC 5 Hardware and ordering
  • Module 2: Starting with DIGSI 5
  • Module 3: Working with SIPROTEC 5 in online mode
  • Module 4: System Functions
  • Module 5: Function Groups
  • Module 6: SIPROTEC 7SJ8
  • Module 7: SIPROTEC 7SA8
  • Module 8: SIPROTEC 7UT8
  • Module 9: SIPROTEC 7SS8
  • Module 10: SIPROTEC 7SK8
  • Module 11: SIPROTEC 7VK8
  • Module 12: SIPROTEC 7SD8
  • Module 13: SIPROTEC 7SL8
  • Module 14: SIPROTEC 7SX8
  • Module 15: SIPROTEC 7UM8
  • Module 16: SIPROTEC 7MD8
  • Module 17: Functions and Settings
  • Module 18: Signals and Masking IO
  • Module 19: CFC
  • Module 20: Control Functions
  • Module 21: Display Page configuration
  • Module 22: Functional Tests
  • Module 23: Measured Values
  • Module 24: Power Quality
  • Module 25: Supervision
  • Module 26: Communication
  • Module 27: IEC 61850
  • Module 28: Digital Twin
  • Module 29: Case Study 7UT8
  • Module 30: Case Study 7VK8
  • Module 31: Case Study 7SA8
  • Module 32: Case Study 7SS8

Course Details (Note: This part is continuously updating)

Module: SIPROTEC 5 Hardware and order

  • SIPROTEC5 Hardware
  • DIGSI 5 installation and DDD
  • General Settings
  • DIGSI 5 User interface
  • New project + Add device (Offline)
  • Modify the order code in the SIPROTEC online configurator
  • SIPROTEC 5 Online Configurator
  • Function Point
  • SIP 5 Configuration Procedure

Module: Online & Working with SIPROTEC 5

  • Connect to SIPROTEC 5
  • Indications
  • Fault Recording
  • Log
  • Reading Indications on the On-Site Operation Panel
  • Reading Indications from the PC with DIGSI 5
  • Displaying Indications
  • Operational Log
  • Fault Log
  • Switching-Device Log
  • Ground-Fault Log
  • Setting-History Log
  • User Log
  • Security Log
  • Device-Diagnosis Log
  • Communication Log
  • Communication-Supervision Log
  • Motor-Starting Log
  • Saving and Deleting the Logs
  • Spontaneous Indication Display in DIGSI 5
  • Spontaneous Fault Display on the On-Site Operation Panel
  • Stored Indications in the SIPROTEC 5 Device
  • Resetting Stored Indications of the Function Group
  • Test Mode and Influence of Indications on Substation Automation Technology
  • Changing the Transformation Ratios of the Transformer on the Device

Module: System Functions

  • Sampling-Frequency Tracking and Frequency Tracking Groups
  • Text Structure and Reference Number for Settings and Indications
  • Processing Quality Attributes
  • Protection Communication
  • Date and Time Synchronization
  • User-Defined Objects
  • Device Settings
  • Data Types
  • Function Control
  • Connection Examples
  • Chatter blocking
  • Settings-Group Switching

Module: Function Groups

  • Voltage current 3-Phase
  • Circuit-breaker
  • Process Monitor
  • Voltage-current 1-phase
  • Motor
  • Line
  • Voltage 3-Phase
  • Analog Units
  • User-Defined Function Group
  • Recording
  • Motor Monitor
  • Current-Flow Criterion
  • Circuit-Breaker Condition for the Motor
  • Closure Detection
  • Motor-State Detection
  • Cold-Load Pickup Detection
  • Thermal Replica Rotor
  • Capacitor Bank

Module: Functions and Settings

  • Power-System Data
  • Overcurrent Protection, Phases
  • Overcurrent Protection, Ground
  • Line Differential Protection
  • Stub Differential Protection
  • Restricted Ground-Fault Protection
  • Distance Protection with Reactance Method (RMD)
  • Distance Protection with Classic Method
  • Impedance Protection
  • Power-Swing Blocking
  • Teleprotection with Distance Protection
  • Universal Teleprotection with Distance Protection
  • Ground-Fault Protection for High-Resistance Ground Faults in Grounded Systems
  • Teleprotection with Ground-Fault Protection
  • Universal Teleprotection with Ground-Fault Protection
  • Echo and Tripping in the Event of Weak Infeed 874
  • Tripping with Missing or Weak Infeed According to French Specification
  • External Trip Initiation
  • Automatic Reclosing Function
  • Directional Overcurrent Protection, Phases
  • Positive-Sequence Overcurrent Protection
  • Instantaneous High-Current Tripping
  • Group Indications of Overcurrent Protection Functions
  • Overcurrent Protection, 1-Phase
  • Voltage-Dependent Overcurrent Protection, Phases
  • Sensitive Ground-Fault Detection
  • Non-Directional Intermittent Ground-Fault Protection
  • Directional Intermittent Ground-Fault Protection
  • Negative-Sequence Protection
  • Directional Negative-Sequence Protection with Current-Independent Time Delay
  • Undercurrent Protection
  • Overvoltage Protection with 3-Phase Voltage
  • Overvoltage Protection with Positive-Sequence Voltage
  • Overvoltage Protection with Negative-Sequence Voltage
  • Overvoltage Protection with Positive-Sequence Voltage and Compounding
  • Overvoltage Protection with Zero-Sequence Voltage/Residual Voltage
  • Overvoltage Protection with Any Voltage
  • Undervoltage Protection with 3-Phase Voltage
  • Undervoltage Protection with Positive-Sequence Voltage
  • Undervoltage Protection with Any Voltage
  • Rate-of-Voltage-Change Protection
  • Undervoltage-Controlled Reactive-Power Protection
  • Voltage-Comparison Supervision
  • Fault Locator
  • Fault Locator Plus
  • Over frequency Protection
  • Under frequency Protection
  • Rate of Frequency Change Protection
  • Under frequency Load Shedding
  • Phase-Sequence Switchover
  • Instantaneous Tripping at Switch onto Fault
  • Thermal Overload Protection, 3-Phase – Advanced
  • Thermal Overload Protection, 1-Phase
  • Temperature Supervision
  • Circuit-Breaker Failure Protection
  • Circuit-Breaker Restrike Protection
  • Out-of-Step Protection
  • Inrush-Current and 2nd Harmonic Detection
  • Power Protection (P, Q), 3-Phase
  • Current-Jump Detection
  • Voltage-Jump Detection
  • Vector-Jump Protection
  • Arc Protection
  • Voltage Measuring-Point Selection

Module: Specific Functions

  • Current-Unbalance Protection for Capacitors, 1-Phase
  • Peak Overvoltage Protection for Capacitors
  • Motor-Starting Time Supervision
  • Motor Restart Inhibit
  • Load-Jam Protection Motor
  • Thermal Overload Protection, Rotor

Module: Control Functions

  • Introduction
  • Switching Devices
  • Switching Sequences
  • Control Functionality
  • Synchronization Function
  • User-Defined Function Block [Control]
  • CFC-Chart Settings
  • Tap Changers
  • Voltage Controller
  • Point-on-Wave Switch

Module: Functional Tests

  • Direction Test of the Phase Quantities
  • Functional Test Protection Communication
  • Functional Test of the Line Differential Protection
  • Functional Test for Overvoltage Protection with Zero-Sequence Voltage/Displacement Voltage
  • Primary and Secondary Tests of the Circuit-Breaker Failure Protection
  • Circuit-Breaker Test
  • Out-of-Step Protection Function Test
  • Functional Test of the Inrush-Current Detection
  • Functional Test of the Trip-Circuit Supervision
  • Power-Swing Blocking Functional Test
  • Functional Test for the Phase-Rotation Reversal
  • Functional Test for Overvoltage Protection with Zero-Sequence Voltage/Residual Voltage
  • Directional Testing for Isolated or Resonant-Grounded Systems
  • Primary and Secondary Testing of the Synchronization Function
  • Commissioning Hints for Voltage Control

Module: Measured Values

  • Operational Measured Values
  • Fundamental and Symmetrical Components
  • THD and Harmonics
  • Minimum/Maximum Values
  • Average Values
  • Energy Values
  • Circuit-Breaker Monitoring
  • Statistical Values of the Primary System

Module: Power Quality

  • Voltage Variation
  • Voltage Unbalance
  • THD and Harmonics
  • Total Demand Distortion

Module: Supervision

  • Resource-Consumption Supervision
  • Supervision of the Secondary System
  • Supervision of the Device Hardware
  • Supervision of Device Firmware
  • Supervision of Hardware Configuration
  • Supervision of Communication Connections
  • Error Responses and Corrective Measures
  • Group Indications

Module: IEC 61850

  • External Signals
  • Quality Processing/Affected by the User for Received GOOSE Values
  • Quality Processing/Affected by the User in CFC Charts
  • Quality Processing/Affected by the User in Internal Device Functions

More info and update about this course: Contac us

To participate in this face-to-face / online training course: contact us

  • The most complete training in DIGSI 5 & SIPROTEC 5 training (basic to advanced level)
  • By a reputed instructor ( Dr. Saeed Roostaee)
  • Face-to-face training
  • Location (we can manage it in our office or your office or a hotel nearby you)
  • Duration: 3 days (24 hours)

The following list provides an overview of the tasks we will do in this training:

  • DIGSI 5 Setup
  • Additional Steps upon First Time Use of DIGSI 5
  • DIGSI 5 startup
  • DIGSI 5 and SIPROTEC 5 Vs. DIGSI 4 and SIPROTEC 4
  • User Interface, Project, and Project Tree
  • Creating a topology as a single-line configuration
  • Incorporating SIPROTEC 5 devices into the topology
  • Configuring hardware of a SIPROTEC 5 device
  • Defining the functional scope of a SIPROTEC 5 device
  • Defining individual function settings
  • Routing information
  • Editing display pages
  • Configuring function charts (CFC)
  • Configuring the communication network and setting communication settings
  • Displaying saved measured values and indications
  • Displaying saved fault records and evaluating them with SIGRA
  • Exporting and printing data
  • Creating test sequences
  • Transmitting settings values from DIGSI 5 to the SIPROTEC 5 device
  • Transmitting settings values from the SIPROTEC 5 device to DIGSI 5 and saving them in files
  • Transmitting indications, measured values, and fault records from the SIPROTEC 5 device to DIGSI 5 and saving them in files
  • Setting limiting values
  • Testing SIPROTEC 5 devices and functions
  • Controlling equipment
  • Initial startup or restart of the SIPROTEC 5 device
  • Setting the date and time of the SIPROTEC 5 device
  • Several versions of one device type
  • Working Offline and Online with SIPROTEC 5 device
  • Managing Device Drivers
  • Firmware for SIPROTEC 5 devices
  • Firmware for communication modules
  • Communication protocols
  • Communication mappings
  • Checking for New DIGSI 5 Version
  • Library elements
  • Elements for the hardware catalog
  • Selecting an application template
  • Open the DIGSI 5 Information Routing to route information with complete details
  • Open the DIGSI 5 Display Editor to edit display pages with complete details
  • Open the DIGSI 5 Function-Chart (CFC) Editor to configure additional functions such as interlockings with complete details
  • Open the DIGSI 5 Network View to configure a communication network with complete details
  • Display saved measured values and indications in DIGSI 5 and SIPROTEC 5 with complete details
  • Display saved fault records in DIGSI 5 with complete details
  • Export and print data in DIGSI 5 with complete details
  • Transfer indications, measured values, and fault records from the SIPROTEC 5 device to DIGSI 5 with complete details
  • Test SIPROTEC 5 devices and functions using the test suit in DIGSI 5 with complete details
  • Control Equipment with complete details
  • Find and edit SIPROTEC 5 devices connected to a network with complete details
  • Config and parameters of the SIPROTEC 5 Overcurrent protection phases 50/51
  • Config and parameters of the SIPROTEC 5 Overcurrent protection, ground 50N/51N
  • Config and parameters of the SIPROTEC 5 Directional overcurrent protection 67
  • Config and parameters of the SIPROTEC 5 Negative sequence 46
  • Config and parameters of the SIPROTEC 5 Voltage-dependent overcurrent protection 51V
  • Config and parameters of the SIPROTEC 5 Directional overcurrent protection, ground 67N
  • Communication mapping
  • Device settings
  • Time settings
  • Power system data
  • Measuring points info and settings
  • Fault recorder settings
  • CT connection types
  • VT connection types
  • Circuit-breaker function group
  • Voltage-current 3-phase function group
  • Entering settings based on secondary, primary, or percent
  • Current-flow criterion:
  • Closure detection:
  • Current thresh. CB open parameter
  • Output time parameter
  • Blk. Op. Ind. & Fault Rec. parameter
  • Reference value parameter
  • Current limitation Imax parameter
  • 7SJ8x Overcurrent Protection Functions
  • SIPROTEC relay families with the features and applications
  • SIPROTEC 7SX800
  • SIPROTEC 5 family
  • Browser-based user interface
  • Checking and adjusting the values of a specific setting
  • Comparing the values of 2 or more devices
  • Checking a setting value against a user-defined setting to verify whether the setting value differs from the default value specified by Siemens
  • Querying a value in order to adjust a test case, for example to preset the tripping current
  • Viewing all types of measured values, for example, functional measured values and derived values such as the minimum/maximum and mean values
  • Displaying the deviation of the expected measured-value quality.
  • Explain & Config signal “fault log is full”
  • Setting-History Log
  • Operational Log
  • Fault Log
  • Fault Definition
  • Ground-Fault Log
  • Motor-Starting Log
  • Security Log
  • Device-Diagnosis Log
  • Communication Log
  • Communication-Supervision Log
  • Reading Fault Records
  • Config Sampled values of analog measuring inputs (currents and voltages) in the DIGSI 5 & SIPROTEC 5 fault-record
  • Config Internal measured values of measured value preprocessing in DIGSI 5
  • Config Internal function and operational measured values in SIPROTEC 5 fault recorder
  • Config SIPROTEC 5 Binary status signals (internal or external) into the fault recorders
  • User-Defined Configuration of the Start Criterion for Fault Recording
  • Spontaneous indication in DIGSI 5
  • Copy online SIPROTEC 5 device to the DIGSI 5 project
  • And much more will be added soon …

Additional information:

SIPROTEC 5 IO Modules:

  • SIPROTEC 5 IO201 with 8 binary inputs, 6 binary outputs (6 fast relays), 4 current transformers
  • SIPROTEC 5 IO202 with 8 Binary inputs, 6 Binary outputs (6 Fast relays), 4 Current transformers, and 4 Voltage transformers
  • SIPROTEC 5 IO203 with 4 binary inputs, 4 binary outputs (4 fast relays), 8 current transformers
  • SIPROTEC 5 IO205 with 12 Binary inputs and 16 Binary outputs (16 Standard relays)
  • SIPROTEC 5 IO206 with 6 binary inputs and 7 binary outputs (7 standard relays)
  • SIPROTEC 5 IO207 with 16 binary inputs and 8 binary outputs
  • SIPROTEC 5 IO208 with 4 binary inputs and 11 binary outputs, 4 current transformers, and 4 voltage transformers
  • SIPROTEC 5IO209 with 8 Binary inputs and 4 Binary outputs
  • SIPROTEC 5 IO214 with 2 Binary inputs, 5 Binary outputs (5 Fast relays), 4 Current transformers, and 4 Voltage transformers
  • SIPROTEC 5 CB202 for 3 Plug-in modules, port positions M, N, P

more details on SIPROTEC 5 Hardware Description

SIPROTEC 5 relays and fields of application
SIPROTEC 5 relays

The spontaneous indication log which is available in online mode is a very good tool for testing and commissioning the SIPROTEC 5 devices. This log shows the indications immediately at the moment of occurrence (No wait for a cyclical update or initiating the manual update).

DIGSI 5 spontaneous indication

DIGSI 5 & SIPROTEC 5 topics:

Parameter set, Connection to an online device, Updating firmware, showing truncated texts completely, Showing tooltips, The Add new device entry is an action. This lets you open a dialog to add a new SIPROTEC 5 device./ Open the Device View to configure the hardware of a SIPROTEC 5 device. Adjusting Working Area, Maximizing the DIGSI 5 working area, Minimizing DIGSI 5 working-area objects, Splitting the working area vertically or horizontally in DIGSI 5, Separating objects from the DIGSI 5 working area, Restoring the working area, Starting to Add Using the Project Tree in DIGSI 5, Single-line and display elements in DIGSI 5, Global DIGSI 5 Library, Starting to Add Using the Single-Line Configuration and the Library, Select Voltage Variant, Select function point class, And port J functionality, Application Template, Communication firmware version, Network view, and device view, Plug-in modules, Siprotec 5 online configurator, Update short product code list /TNS list, For instance, line protection, SIPROTEC 5 7SA, SIPROTEC 5 7sa82, SIPROTEC 5 7sa86, SIPROTEC 5 7sa87, SIPROTEC 5 7SJ, SIPROTEC 5 7SD, SIPROTEC 5 7SL, SIPROTEC 5 7VK, Overcurrent protection, phases 50/51, Overcurrent protection, ground 50N/51N, Directional overcurrent protection 67, Negative sequence 46, Voltage-dependent overcurrent protection 51V, Directional overcurrent protection, ground 67N

DIGSI 4 offline video training package:
Total length: 185 Minutes
Language: English
Trainer: Dr. Saeed Roostaee

DIGSI 5 offline video training package:
Total length: 435 Minutes
Language: English
Trainer: Dr. Saeed Roostaee

IEC 61850 System Configurator offline video training package:
Total length: 246 Minutes (4 hours)
Language: English
Trainer: Dr. Saeed Roostaee

+ Free and fast technical support +Free certificate for each course + Continuous update

Download:

Contact me WhatsApp: +989129613659

saeed61850@gmail.com/